A V Okishev

Summary

Affiliation: University of Rochester
Country: USA

Publications

  1. ncbi request reprint Highly stable, all-solid-state Nd:YLF regenerative amplifier
    Andrey V Okishev
    Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623, USA
    Appl Opt 43:6180-6. 2004
  2. doi request reprint A stable mid-IR, GaSb-based diode laser source for the cryogenic target layering at the Omega Laser Facility
    A V Okishev
    Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, NY 1462, USA
    Opt Express 17:15760-5. 2009
  3. doi request reprint Optical differentiation and multimillijoule approximately 150 ps pulse generation in a regenerative amplifier with a temperature-tuned intracavity volume Bragg grating
    A V Okishev
    Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, New York 14623, USA
    Appl Opt 49:1331-4. 2010
  4. doi request reprint Characterization of highly stable mid-IR, GaSb-based laser diodes
    A V Okishev
    Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, NY 14623, USA
    Opt Express 19:9863-7. 2011
  5. doi request reprint Highly efficient room-temperature Yb:YAG ceramic laser and regenerative amplifier
    A V Okishev
    Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623, USA
    Opt Lett 37:1199-201. 2012

Detail Information

Publications5

  1. ncbi request reprint Highly stable, all-solid-state Nd:YLF regenerative amplifier
    Andrey V Okishev
    Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623, USA
    Appl Opt 43:6180-6. 2004
    ..Excellent long-term output-pulse-energy stability of better than 1% rms fluctuations has been achieved with excellent beam quality (<1% ellipticity)...
  2. doi request reprint A stable mid-IR, GaSb-based diode laser source for the cryogenic target layering at the Omega Laser Facility
    A V Okishev
    Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, NY 1462, USA
    Opt Express 17:15760-5. 2009
    ..More than 50 mW of output power has been achieved at 14 degrees C with high spectral and output-power stability...
  3. doi request reprint Optical differentiation and multimillijoule approximately 150 ps pulse generation in a regenerative amplifier with a temperature-tuned intracavity volume Bragg grating
    A V Okishev
    Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, New York 14623, USA
    Appl Opt 49:1331-4. 2010
    ..12 mJ approximately 150 ps pulses with a TEM(00) beam profile have been generated at the 5 Hz repetition rate in the nanosecond-pulse-seeded regenerative amplifier with a VBG that is temperature detuned from the central wavelength...
  4. doi request reprint Characterization of highly stable mid-IR, GaSb-based laser diodes
    A V Okishev
    Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, NY 14623, USA
    Opt Express 19:9863-7. 2011
    ..Up to 54 mW of output power was demonstrated in a 3150- to 3180-nm-wavelength range with <20-nm FWHM spectral width...
  5. doi request reprint Highly efficient room-temperature Yb:YAG ceramic laser and regenerative amplifier
    A V Okishev
    Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623, USA
    Opt Lett 37:1199-201. 2012
    ..6 is important for achieving maximum laser efficiency with a Gaussian-like beam profile. A regenerative Yb:YAG ceramic amplifier with a maximum output energy of 14.5 mJ and a super-Gaussian beam profile is demonstrated...