M Saiful Huq

Summary

Affiliation: Thomas Jefferson University
Country: USA

Publications

  1. ncbi request reprint Experimental determination of fluence correction factors at depths beyond dmax for a Farmer type cylindrical ionization chamber in clinical electron beams
    M S Huq
    Department of Radiation Oncology, Jefferson Medical College of Thomas Jefferson University, Philadelphia, Pennsylvania 19107, USA
    Med Phys 24:1609-13. 1997
  2. ncbi request reprint A dosimetric comparison of various multileaf collimators
    M Saiful Huq
    Department of Radiation Oncology, Kimmel Cancer Center of Jefferson Medical College, Thomas Jefferson University, Philadelphia, PA 19107, USA
    Phys Med Biol 47:N159-70. 2002
  3. ncbi request reprint Reference dosimetry in clinical high-energy electron beams: comparison of the AAPM TG-51 and AAPM TG-21 dosimetry protocols
    M Saiful Huq
    Department of Radiation Oncology, Kimmel Cancer Center of Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania 19107, USA
    Med Phys 28:2077-87. 2001
  4. ncbi request reprint Experimental determination of depth-scaling factors and central axis depth dose for clinical electron beams
    M S Huq
    Department of Radiation Oncology, Kimmel Cancer Center of Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania 19107, USA
    Int J Cancer 96:232-7. 2001
  5. ncbi request reprint A generalized film technique for the verification of vertex fields used in the treatment of brain tumors
    M S Huq
    Department of Radiation Oncology, Kimmel Cancer Center of Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania 19107, USA
    Med Phys 25:1685-91. 1998
  6. ncbi request reprint Reference dosimetry in clinical high-energy photon beams: comparison of the AAPM TG-51 and AAPM TG-21 dosimetry protocols
    M Saiful Huq
    Department of Radiation Oncology, Kimmel Cancer Center of Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania 19107, USA
    Med Phys 28:46-54. 2001
  7. ncbi request reprint An investigation of a model of percentage depth dose for irregularly shaped fields
    M Hossain
    Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
    Int J Cancer 96:140-5. 2001
  8. ncbi request reprint Roles of replication protein A and DNA-dependent protein kinase in the regulation of DNA replication following DNA damage
    Y Wang
    Department of Radiation Oncology, Kimmel Cancer Center of Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania 19107, USA
    J Biol Chem 274:22060-4. 1999
  9. ncbi request reprint Comparison of the IAEA TRS-398 and AAPM TG-51 absorbed dose to water protocols in the dosimetry of high-energy photon and electron beams
    M S Huq
    Department of Radiation Oncology, Kimmel Cancer Center of Jefferson Medical College, Thomas Jefferson University, Philadelphia, PA 19107, USA
    Phys Med Biol 46:2985-3006. 2001
  10. doi request reprint Dosimetric influences of rotational setup errors on head and neck carcinoma intensity-modulated radiation therapy treatments
    Weihua Fu
    Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, PA 15237, USA
    Med Dosim 38:125-32. 2013

Detail Information

Publications12

  1. ncbi request reprint Experimental determination of fluence correction factors at depths beyond dmax for a Farmer type cylindrical ionization chamber in clinical electron beams
    M S Huq
    Department of Radiation Oncology, Jefferson Medical College of Thomas Jefferson University, Philadelphia, Pennsylvania 19107, USA
    Med Phys 24:1609-13. 1997
    ..The largest difference between the measured value of R50 and that calculated by using the above equation has been found to be about 1 mm at 22 MeV...
  2. ncbi request reprint A dosimetric comparison of various multileaf collimators
    M Saiful Huq
    Department of Radiation Oncology, Kimmel Cancer Center of Jefferson Medical College, Thomas Jefferson University, Philadelphia, PA 19107, USA
    Phys Med Biol 47:N159-70. 2002
    ..There is no perfect MLC system that can be recommended, rather each one has unique advantages and disadvantages that should be weighed with comfort, ease and cost effectiveness for clinical use...
  3. ncbi request reprint Reference dosimetry in clinical high-energy electron beams: comparison of the AAPM TG-51 and AAPM TG-21 dosimetry protocols
    M Saiful Huq
    Department of Radiation Oncology, Kimmel Cancer Center of Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania 19107, USA
    Med Phys 28:2077-87. 2001
    ....
  4. ncbi request reprint Experimental determination of depth-scaling factors and central axis depth dose for clinical electron beams
    M S Huq
    Department of Radiation Oncology, Kimmel Cancer Center of Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania 19107, USA
    Int J Cancer 96:232-7. 2001
    ..For both phantoms, either the TG-25-recommended value or the experimentally determined values of rho(eff) yielded agreement to within about 2 mm among all depth doses in water at the depths of clinical relevance...
  5. ncbi request reprint A generalized film technique for the verification of vertex fields used in the treatment of brain tumors
    M S Huq
    Department of Radiation Oncology, Kimmel Cancer Center of Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania 19107, USA
    Med Phys 25:1685-91. 1998
    ..In all of these cases, the coincidence of the projection of the isocenter for the lateral (or oblique) and the vertex fields was found to be within 3 mm...
  6. ncbi request reprint Reference dosimetry in clinical high-energy photon beams: comparison of the AAPM TG-51 and AAPM TG-21 dosimetry protocols
    M Saiful Huq
    Department of Radiation Oncology, Kimmel Cancer Center of Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania 19107, USA
    Med Phys 28:46-54. 2001
    ....
  7. ncbi request reprint An investigation of a model of percentage depth dose for irregularly shaped fields
    M Hossain
    Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
    Int J Cancer 96:140-5. 2001
    ..The model predicts the percent depth dose with acceptable accuracy for any arbitrary shape of fields. We report on results for 6- and 18-MV photon beams and for a number of irregularly shaped fields...
  8. ncbi request reprint Roles of replication protein A and DNA-dependent protein kinase in the regulation of DNA replication following DNA damage
    Y Wang
    Department of Radiation Oncology, Kimmel Cancer Center of Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania 19107, USA
    J Biol Chem 274:22060-4. 1999
    ....
  9. ncbi request reprint Comparison of the IAEA TRS-398 and AAPM TG-51 absorbed dose to water protocols in the dosimetry of high-energy photon and electron beams
    M S Huq
    Department of Radiation Oncology, Kimmel Cancer Center of Jefferson Medical College, Thomas Jefferson University, Philadelphia, PA 19107, USA
    Phys Med Biol 46:2985-3006. 2001
    ..A detailed analysis of the reasons for the discrepancies is made which includes comparing the formalisms, correction factors and the quantities in the two protocols...
  10. doi request reprint Dosimetric influences of rotational setup errors on head and neck carcinoma intensity-modulated radiation therapy treatments
    Weihua Fu
    Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, PA 15237, USA
    Med Dosim 38:125-32. 2013
    ....
  11. ncbi request reprint Deconvolution of detector size effect for output factor measurement for narrow Gamma Knife radiosurgery beams
    G Bednarz
    Department of Radiation Oncology, Kimmel Cancer Center of Jefferson Medical College, Thomas Jefferson University, Philadelphia, PA 19107, USA
    Phys Med Biol 47:3643-9. 2002
    ..984, 0.956 and 0.87. The corrected OF4 was 0.881 +/- 0.012 for the diamond detector and 0.851 +/- 0.012 for the ion chamber, supporting the manufacturer's revised value for this collimator...
  12. doi request reprint Single magnetic resonance imaging vs magnetic resonance imaging/computed tomography planning in cervical cancer brachytherapy
    S Beriwal
    Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, PA, USA
    Clin Oncol (R Coll Radiol) 21:483-7. 2009
    ....