Marcel W Pruessner

Summary

Affiliation: Naval Medical Center
Country: USA

Publications

  1. doi request reprint Waveguide micro-opto-electro-mechanical resonant chemical sensors
    Marcel W Pruessner
    Naval Research Laboratory, 4555 Overlook Avenue SW, Washington, DC 20375, USA
    Lab Chip 10:762-8. 2010
  2. doi request reprint Integrated waveguide-DBR microcavity opto-mechanical system
    Marcel W Pruessner
    Naval Research Laboratory, Washington, DC 20375, USA
    Opt Express 19:21904-18. 2011
  3. ncbi request reprint Integrated waveguide Fabry-Perot microcavities with silicon/air Bragg mirrors
    Marcel W Pruessner
    Photonics Technology Branch, Naval Research Laboratory, 4555 Overlook Avenue SW, Washington, DC 20375, USA
    Opt Lett 32:533-5. 2007
  4. doi request reprint Demonstration of a mode-conversion cavity add-drop filter
    Marcel W Pruessner
    Naval Research Laboratory NRL, Washington, District of Columbia 20375, USA
    Opt Lett 36:2230-2. 2011

Detail Information

Publications4

  1. doi request reprint Waveguide micro-opto-electro-mechanical resonant chemical sensors
    Marcel W Pruessner
    Naval Research Laboratory, 4555 Overlook Avenue SW, Washington, DC 20375, USA
    Lab Chip 10:762-8. 2010
    ..These improvements suggest parts-per-billion limit-of-detection levels for a variety of toxic chemicals...
  2. doi request reprint Integrated waveguide-DBR microcavity opto-mechanical system
    Marcel W Pruessner
    Naval Research Laboratory, Washington, DC 20375, USA
    Opt Express 19:21904-18. 2011
    ..The resulting collapse of the resonance linewidth implies a strong increase in effective mechanical quality-factor, which is of interest for high-resolution sensing...
  3. ncbi request reprint Integrated waveguide Fabry-Perot microcavities with silicon/air Bragg mirrors
    Marcel W Pruessner
    Photonics Technology Branch, Naval Research Laboratory, 4555 Overlook Avenue SW, Washington, DC 20375, USA
    Opt Lett 32:533-5. 2007
    ..Various devices exhibit Q=26963, FWHM=0.060 nm, finesse F=489, free spectral range FSR=81.7 nm, and DBR mirror reflectance R=99.4%. Thermo-optic tuning over 6.7 nm is also demonstrated...
  4. doi request reprint Demonstration of a mode-conversion cavity add-drop filter
    Marcel W Pruessner
    Naval Research Laboratory NRL, Washington, District of Columbia 20375, USA
    Opt Lett 36:2230-2. 2011
    ..Add-drop functionality is demonstrated in a three-port integrated silicon-on-insulator device...