Markus Henningsson

Summary

Affiliation: King's College London
Country: UK

Publications

  1. doi request reprint Contrast-enhanced specific absorption rate-efficient 3D cardiac cine with respiratory-triggered radiofrequency gating
    Markus Henningsson
    Cardiovascular Division, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
    J Magn Reson Imaging 37:986-92. 2013
  2. doi request reprint Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator
    Markus Henningsson
    Division of Imaging Sciences and Biomedical Engineering, King s College London, London, United Kingdom
    Magn Reson Med 69:486-94. 2013
  3. doi request reprint Whole-heart coronary MR angiography with 2D self-navigated image reconstruction
    Markus Henningsson
    Division of Imaging Sciences and Biomedical Engineering, King s College London, London, United Kingdom
    Magn Reson Med 67:437-45. 2012
  4. doi request reprint Whole-heart coronary MRA with 3D affine motion correction using 3D image-based navigation
    Markus Henningsson
    Division of Imaging Sciences and Biomedical Engineering, King s College London, London, UK
    Magn Reson Med 71:173-81. 2014
  5. doi request reprint Whole-heart coronary MR angiography using image-based navigation for the detection of coronary anomalies in adult patients with congenital heart disease
    Markus Henningsson
    Division of Imaging Sciences and Biomedical Engineering, King s College London, London, United Kingdom
    J Magn Reson Imaging 43:947-55. 2016
  6. doi request reprint Highly efficient respiratory motion compensated free-breathing coronary MRA using golden-step Cartesian acquisition
    Claudia Prieto
    King s College London, Division of Imaging Sciences and Biomedical Engineering, London, UK Pontificia Universidad Católica de Chile, Escuela de Ingeniería, Santiago, Chile
    J Magn Reson Imaging 41:738-46. 2015
  7. doi request reprint Three-dimensional heart locator for whole-heart coronary magnetic resonance angiography
    Mehdi H Moghari
    Department of Cardiology, Boston Children s Hospital, Boston, Massachusetts, USA Department of Pediatrics, Harvard Medical School, Boston, Massachusetts, USA Department of Medicine, Harvard Medical School, Boston, Massachusetts, USA
    Magn Reson Med 71:2118-26. 2014
  8. doi request reprint 100% Efficient three-dimensional coronary MR angiography with two-dimensional beat-to-beat translational and bin-to-bin affine motion correction
    Andrew P Aitken
    King s College London, Division of Imaging Sciences, and Biomedical Engineering, St Thomas Hospital, London, UK
    Magn Reson Med 74:756-64. 2015
  9. pmc Coronary artery size and origin imaging in children: a comparative study of MRI and trans-thoracic echocardiography
    Tarique Hussain
    Division of Imaging Sciences, King s College London, NIHR Biomedical Research Centre at Guy s and St Thomas NHS Foundation Trust, London, UK
    BMC Med Imaging 15:48. 2015
  10. doi request reprint A new framework for interleaved scanning in cardiovascular MR: Application to image-based respiratory motion correction in coronary MR angiography
    Markus Henningsson
    Division of Imaging Sciences and Biomedical Engineering, King s College London, London, UK Wellcome Trust and EPSRC Medical Engineering Center, King s College London, London, UK BHF Centre of Excellence, King s College London, London, UK NIHR Biomedical Research Centre, King s College London, London, UK
    Magn Reson Med 73:692-6. 2015

Collaborators

Detail Information

Publications14

  1. doi request reprint Contrast-enhanced specific absorption rate-efficient 3D cardiac cine with respiratory-triggered radiofrequency gating
    Markus Henningsson
    Cardiovascular Division, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
    J Magn Reson Imaging 37:986-92. 2013
    ....
  2. doi request reprint Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator
    Markus Henningsson
    Division of Imaging Sciences and Biomedical Engineering, King s College London, London, United Kingdom
    Magn Reson Med 69:486-94. 2013
    ....
  3. doi request reprint Whole-heart coronary MR angiography with 2D self-navigated image reconstruction
    Markus Henningsson
    Division of Imaging Sciences and Biomedical Engineering, King s College London, London, United Kingdom
    Magn Reson Med 67:437-45. 2012
    ..The visualized vessel length of the right coronary artery could be significantly improved with a multiple targeted 2D self-navigation approach, compared to 2DSN method...
  4. doi request reprint Whole-heart coronary MRA with 3D affine motion correction using 3D image-based navigation
    Markus Henningsson
    Division of Imaging Sciences and Biomedical Engineering, King s College London, London, UK
    Magn Reson Med 71:173-81. 2014
    ..The purpose of this work was to implement 3D affine motion correction for Cartesian whole-heart CMRA using a 3D navigator (3D-NAV) to allow for data acquisition throughout the whole respiratory cycle...
  5. doi request reprint Whole-heart coronary MR angiography using image-based navigation for the detection of coronary anomalies in adult patients with congenital heart disease
    Markus Henningsson
    Division of Imaging Sciences and Biomedical Engineering, King s College London, London, United Kingdom
    J Magn Reson Imaging 43:947-55. 2016
    ..The purpose of this study was to evaluate a recently developed two-dimensional (2D) image-based navigation approach (iNAVG+C ) combined with respiratory bellows gating for CMRA in patients with congenital heart disease...
  6. doi request reprint Highly efficient respiratory motion compensated free-breathing coronary MRA using golden-step Cartesian acquisition
    Claudia Prieto
    King s College London, Division of Imaging Sciences and Biomedical Engineering, London, UK Pontificia Universidad Católica de Chile, Escuela de Ingeniería, Santiago, Chile
    J Magn Reson Imaging 41:738-46. 2015
    ..To develop an efficient 3D affine respiratory motion compensation framework for Cartesian whole-heart coronary magnetic resonance angiography (MRA)...
  7. doi request reprint Three-dimensional heart locator for whole-heart coronary magnetic resonance angiography
    Mehdi H Moghari
    Department of Cardiology, Boston Children s Hospital, Boston, Massachusetts, USA Department of Pediatrics, Harvard Medical School, Boston, Massachusetts, USA Department of Medicine, Harvard Medical School, Boston, Massachusetts, USA
    Magn Reson Med 71:2118-26. 2014
    ..We therefore developed and validated a motion compensation technique based on three-dimensional (3D) spatial registration in which data are accepted throughout the respiratory cycle...
  8. doi request reprint 100% Efficient three-dimensional coronary MR angiography with two-dimensional beat-to-beat translational and bin-to-bin affine motion correction
    Andrew P Aitken
    King s College London, Division of Imaging Sciences, and Biomedical Engineering, St Thomas Hospital, London, UK
    Magn Reson Med 74:756-64. 2015
    ..To develop a flexible image navigator for 3D coronary MR angiography that allows respiratory motion of variable complexity to be compensated for on different temporal scales...
  9. pmc Coronary artery size and origin imaging in children: a comparative study of MRI and trans-thoracic echocardiography
    Tarique Hussain
    Division of Imaging Sciences, King s College London, NIHR Biomedical Research Centre at Guy s and St Thomas NHS Foundation Trust, London, UK
    BMC Med Imaging 15:48. 2015
    ....
  10. doi request reprint A new framework for interleaved scanning in cardiovascular MR: Application to image-based respiratory motion correction in coronary MR angiography
    Markus Henningsson
    Division of Imaging Sciences and Biomedical Engineering, King s College London, London, UK Wellcome Trust and EPSRC Medical Engineering Center, King s College London, London, UK BHF Centre of Excellence, King s College London, London, UK NIHR Biomedical Research Centre, King s College London, London, UK
    Magn Reson Med 73:692-6. 2015
    ..To describe a new framework for interleaving scans and demonstrate its usefulness for image-based respiratory motion correction in whole heart coronary MR angiography (CMRA)...
  11. doi request reprint Combined coronary lumen and vessel wall magnetic resonance imaging with i-T2prep: influence of nitroglycerin
    Tarique Hussain
    Division of Imaging Sciences and Biomedical Engineering, King s College London, St Thomas Hospital, 4th Floor Lambeth Wing, Westminster Bridge Road, London, SE17EH, UK
    Int J Cardiovasc Imaging 31:77-82. 2015
    ..27.3 %; p = 0.036). This study demonstrates the benefits of NTG for coronary lumen and vessel wall imaging using a combined sequence, i-T2prep. The methodology described here has great potential for future pathophysiological studies. ..
  12. pmc Advanced respiratory motion compensation for coronary MR angiography
    Markus Henningsson
    Division of Imaging Sciences and Biomedical Engineering, The Rayne Institute, King s College London, St Thomas Hospital, London, UK
    Sensors (Basel) 13:6882-99. 2013
    ....
  13. pmc Free-breathing 3D cardiac MRI using iterative image-based respiratory motion correction
    Mehdi H Moghari
    Department of Medicine Cardiovascular Division, Harvard Medical School and Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA
    Magn Reson Med 70:1005-15. 2013
    ..05), while the scan time was reduced by a factor of 1.7...
  14. doi request reprint Flow-independent 3D whole-heart vessel wall imaging using an interleaved T2-preparation acquisition
    Marcelo E Andia
    Division of Imaging Sciences and Biomedical Engineering, King s College London, St Thomas Hospital, London, United Kingdom
    Magn Reson Med 69:150-7. 2013
    ..In this article, we present the technique and preliminary results in healthy subjects...