  1. ncbi request reprint Determination of traces of iron and lead in food and water samples after preconcentration on multiwalled carbon nanotubes
    Mustafa Soylak
    Erciyes University, Faculty of Science, Chemistry Department, 38039 Kayseri, Turkey
    J AOAC Int 95:1183-8. 2012
  2. ncbi request reprint A new preconcentration and separation method for flame atomic absorption spectrometric determinations of some trace metal ions on a Diaion HP-20 column
    M Soylak
    Erciyes University, Faculty of Art and Science, Department of Chemistry, 38039, Kayseri Turkey
    Ann Chim 91:637-47. 2001
  3. ncbi request reprint Copper(II)-rubeanic acid coprecipitation system for separation-preconcentration of trace metal ions in environmental samples for their flame atomic absorption spectrometric determinations
    Mustafa Soylak
    Erciyes University, Faculty of Art and Science, Department of Chemistry, 38039 Kayseri, Turkey
    J Hazard Mater 137:1035-41. 2006
  4. ncbi request reprint Determination of trace metals by atomic absorption spectrometry after coprecipitation with europium hydroxide
    Mustafa Soylak
    Erciyes University, Faculty of Art and Science, Department of Chemistry, 38039 Kayseri, Turkey
    J Hazard Mater 137:1130-4. 2006
  5. ncbi request reprint Diaion SP-850 resin as a new solid phase extractor for preconcentration-separation of trace metal ions in environmental samples
    Mustafa Soylak
    Department of Chemistry, Faculty of Art and Science, Erciyes University, 38039 Kayseri, Turkey
    J Hazard Mater 137:1496-501. 2006
  6. ncbi request reprint Sorbent extraction of rubeanic acid-metal chelates on a new adsorbent: Sepabeads SP70
    Mustafa Soylak
    Erciyes University, Faculty of Arts and Science, Department of Chemistry, 38039 Kayseri, Turkey
    J Hazard Mater 138:195-200. 2006
  7. ncbi request reprint Membrane filtration - atomic absorption spectrometry combination for copper, cobalt, cadmium, lead and chromium in environmental samples
    Mustafa Soylak
    Erciyes Universitesi, Fen Edebiyat Fakultesi, Kimya Bolumu, 38039, Kayseri, Turkey
    Environ Monit Assess 127:169-76. 2007
  8. ncbi request reprint Optimization of microwave assisted digestion procedure for the determination of zinc, copper and nickel in tea samples employing flame atomic absorption spectrometry
    Mustafa Soylak
    Erciyes University, Faculty of Art and Science, Department of Chemistry, 38039 Kayseri, Turkey
    J Hazard Mater 149:264-8. 2007
  9. ncbi request reprint Coprecipitation of gold(III), palladium(II) and lead(II) for their flame atomic absorption spectrometric determinations
    Mustafa Soylak
    Erciyes University, Faculty of Art and Science, Department of Chemistry, 38039 Kayseri, Turkey
    J Hazard Mater 152:656-61. 2008
  10. ncbi request reprint Heavy metal contents of refined and unrefined table salts from Turkey, Egypt and Greece
    Mustafa Soylak
    Faculty of Art and Science, Department of Chemistry, Erciyes University, 38039 Kayseri, Turkey
    Environ Monit Assess 143:267-72. 2008

Collaborators

Detail Information

Publications105 found, 100 shown here

  1. ncbi request reprint Determination of traces of iron and lead in food and water samples after preconcentration on multiwalled carbon nanotubes
    Mustafa Soylak
    Erciyes University, Faculty of Science, Chemistry Department, 38039 Kayseri, Turkey
    J AOAC Int 95:1183-8. 2012
    ..4 fortified lake water and HR-1 Humber River sediment certified reference materials. The method was successfully applied to the determination of trace iron and lead in real environmental samples, and excellent results were achieved...
  2. ncbi request reprint A new preconcentration and separation method for flame atomic absorption spectrometric determinations of some trace metal ions on a Diaion HP-20 column
    M Soylak
    Erciyes University, Faculty of Art and Science, Department of Chemistry, 38039, Kayseri Turkey
    Ann Chim 91:637-47. 2001
    ..The limit of detection for analyte ions (3s, N = 20) was between 23-305 ng/g...
  3. ncbi request reprint Copper(II)-rubeanic acid coprecipitation system for separation-preconcentration of trace metal ions in environmental samples for their flame atomic absorption spectrometric determinations
    Mustafa Soylak
    Erciyes University, Faculty of Art and Science, Department of Chemistry, 38039 Kayseri, Turkey
    J Hazard Mater 137:1035-41. 2006
    ..14 microg/l for iron-3.4 microg/l for lead. The proposed coprecipitation method was successfully applied to water samples from Palas Lake-Kayseri, soil and sediment samples from Kayseri and Yozgat-Turkey...
  4. ncbi request reprint Determination of trace metals by atomic absorption spectrometry after coprecipitation with europium hydroxide
    Mustafa Soylak
    Erciyes University, Faculty of Art and Science, Department of Chemistry, 38039 Kayseri, Turkey
    J Hazard Mater 137:1130-4. 2006
    ..and good results were obtained (relative standard deviations < 10%, recoveries > 95%)...
  5. ncbi request reprint Diaion SP-850 resin as a new solid phase extractor for preconcentration-separation of trace metal ions in environmental samples
    Mustafa Soylak
    Department of Chemistry, Faculty of Art and Science, Erciyes University, 38039 Kayseri, Turkey
    J Hazard Mater 137:1496-501. 2006
    ..The presented procedure was applied to the determination of analytes in tap, river and sea waters, rice, wheat, canned tomato and coal samples with successfully results (recoveries greater than 95%, R.S.D.'s lower than 8%)...
  6. ncbi request reprint Sorbent extraction of rubeanic acid-metal chelates on a new adsorbent: Sepabeads SP70
    Mustafa Soylak
    Erciyes University, Faculty of Arts and Science, Department of Chemistry, 38039 Kayseri, Turkey
    J Hazard Mater 138:195-200. 2006
    ..The method was applied to the determination of analyte ions from various water, wastewater, cow meat and milk, red wine, and tobacco samples with successfully results...
  7. ncbi request reprint Membrane filtration - atomic absorption spectrometry combination for copper, cobalt, cadmium, lead and chromium in environmental samples
    Mustafa Soylak
    Erciyes Universitesi, Fen Edebiyat Fakultesi, Kimya Bolumu, 38039, Kayseri, Turkey
    Environ Monit Assess 127:169-76. 2007
    ..The present method has been successfully applied for the FAAS determinations of analyte ions in real samples including black tea and magnesium salts...
  8. ncbi request reprint Optimization of microwave assisted digestion procedure for the determination of zinc, copper and nickel in tea samples employing flame atomic absorption spectrometry
    Mustafa Soylak
    Erciyes University, Faculty of Art and Science, Department of Chemistry, 38039 Kayseri, Turkey
    J Hazard Mater 149:264-8. 2007
    ..For 10 tea samples analyzed, the concentration achieved for copper, zinc and nickel varied at 6.4-13.1, 7.0-16.5 and 3.1-5.7 (microg g(-1)), respectively...
  9. ncbi request reprint Coprecipitation of gold(III), palladium(II) and lead(II) for their flame atomic absorption spectrometric determinations
    Mustafa Soylak
    Erciyes University, Faculty of Art and Science, Department of Chemistry, 38039 Kayseri, Turkey
    J Hazard Mater 152:656-61. 2008
    ..The proposed procedure was successfully applied to environmental samples for the determinations of analytes...
  10. ncbi request reprint Heavy metal contents of refined and unrefined table salts from Turkey, Egypt and Greece
    Mustafa Soylak
    Faculty of Art and Science, Department of Chemistry, Erciyes University, 38039 Kayseri, Turkey
    Environ Monit Assess 143:267-72. 2008
    ..17-0.47, 0.16-1.57, 0.22-0.48, 0.26-4.68, 0.50-1.64 and 0.14-0.30 microg g(-1), respectively. The results found in the presented work were compared with literature values...
  11. doi request reprint Gadolinium hydroxide coprecipitation system for the separation-preconcentration of some heavy metals
    Mustafa Soylak
    Erciyes University, Faculty of Art and Science, Department of Chemistry, 38039 Kayseri, Turkey
    J Hazard Mater 155:595-600. 2008
    ..52-12.0 microg L(-1). The method was applied to the determination of analytes in real samples and good results were obtained (relative standard deviations <10%, recoveries >95%)...
  12. ncbi request reprint Simultaneous enrichment-separation of metal ions from environmental samples by solid-phase extraction using double-walled carbon nanotubes
    Mustafa Soylak
    University of Erciyes, Faculty of Science and Arts, Chemistry Department, 38039, Kayseri, Turkey
    J AOAC Int 92:1219-24. 2009
    ..Addition and recovery experiments for analyte ions in real water samples gave good results. The validity of the presented SPE method was tested by analysis of HR-1 Humber River Sediment certified reference material for each element...
  13. doi request reprint Utilization of membrane filtration for preconcentration and determination of Cu(II) and Pb(II) in food, water and geological samples by atomic absorption spectrometry
    Mustafa Soylak
    University of Erciyes, Faculty of Science Arts, Chemistry Dept, 38039 Kayseri, Turkey
    Food Chem Toxicol 48:517-21. 2010
    ..The validation of the presented procedure was checked by the analysis of certified reference materials. The optimized method was successfully applied to food, water and geological samples with good results...
  14. doi request reprint Chromium and iron determinations in food and herbal plant samples by atomic absorption spectrometry after solid phase extraction on single-walled carbon nanotubes (SWCNTs) disk
    Mustafa Soylak
    University of Erciyes, Faculty of Science and Arts, Chemistry Department, Kayseri, Turkey
    Food Chem Toxicol 48:1511-5. 2010
    ..The method was successfully applied to the preconcentration and separation of iron and chromium in some food and herbal plant samples from Turkey...
  15. ncbi request reprint Selective preconcentration/separation of copper(II), iron(III), and lead(II) as their N'-benzoyl-N,N-diisobutylthiourea chelates on Amberlite XAD-16 resin
    Mustafa Soylak
    University of Erciyes, Faculty of Science Arts, Chemistry Department, 38039 Kayseri, Turkey
    J AOAC Int 93:720-4. 2010
    ..9 microg/L for Fe, and 3.1 microg/L for Pb. Validation of the procedure was carried out by analyzing standard reference material 1568a (rice flour). The procedure was applied to the determination of analytes in natural water samples...
  16. doi request reprint Sorbent extraction of 4-(2-thiazolylazo) resorcinol (TAR)-metal chelates on Diaion SP-850 adsorption resin in order to preconcentration/separation
    Mustafa Soylak
    Erciyes University, Faculty of Science, Department of Chemistry, 38039 Kayseri, Turkey
    J Hazard Mater 182:704-9. 2010
    ....
  17. doi request reprint Solid-phase extraction of heavy metal ions on bucky tubes disc in natural water and herbal plant samples
    Mustafa Soylak
    Faculty of Science, Chemistry Department, University of Erciyes, 38039, Kayseri, Turkey
    Environ Monit Assess 181:577-86. 2011
    ..The presented procedure was successfully applied to the separation-preconcentration and determination of iron and lead content of some natural water and herbal plant samples from Kayseri, Turkey...
  18. ncbi request reprint Determination of some heavy metals by flame atomic absorption spectrometry before coprecipitation with neodymium hydroxide
    Mustafa Soylak
    University of Erciyes, Faculty of Science, Chemistry Department, 38039, Kayseri, Turkey
    J AOAC Int 94:978-84. 2011
    ..4 fortified lake water). The applications of the procedure were performed by the analysis of water, food, and herbal plants from Turkey...
  19. ncbi request reprint Use of multiwalled carbon nanotube disks for the SPE of some heavy metals as 8-hydroxquinoline complexes
    Mustafa Soylak
    University of Erciyes, Faculty of Science, Chemistry Department, 38039, Kayseri, Turkey
    J AOAC Int 94:1297-303. 2011
    ..The proposed method has been applied to the determination of understudy elements in some pharmaceutical samples and natural water samples from different sites in Turkey...
  20. doi request reprint Determination of Pb(II), Zn(II), Cd(II), and Co(II) ions by flame atomic absorption spectrometry in food and water samples after preconcentration by coprecipitation with Mo(VI)-diethyldithiocarbamate
    Mehmet Tufekci
    Department of Chemistry, Faculty of Sciences, Karadeniz Technical University, 61080 Trabzon, Turkey
    Environ Monit Assess 185:1107-15. 2013
    ..The procedure was successfully applied to seawater and stream water as liquid samples and baby food and dried eggplant as solid samples in order to determine the levels of Pb(II), Cd(II), Zn(II), and Co(II) ions...
  21. doi request reprint Simultaneous preconcentration of Co(II), Ni(II), Cu(II), and Cd(II) from environmental samples on Amberlite XAD-2000 column and determination by FAAS
    Celal Duran
    Department of Chemistry, Karadeniz Technical University, 61080 Trabzon, Turkey
    J Hazard Mater 162:292-9. 2009
    ..The method was successfully applied to some stream waters and mushroom samples from Eastern Black Sea Region (Trabzon city) of Turkey...
  22. ncbi request reprint Sorbent extraction of Pb(II), Cu(II), Ni(II), and Fe(III) ions as 2-(5-bromo-2-pyridylazo)-5-diethylamino-phenol chelates on single-walled carbon nanotube disks prior to their flame atomic absorption spectrometric determinations in animal feeds and natura
    Erkan Yilmaz
    Erciyes University, Faculty of Science, Department of Chemistry, 38039 Kayseri, Turkey
    J AOAC Int 95:1205-10. 2012
    ..Spiking and recovery experiments for the analyte ions in real samples gave good results. Application of the procedure was illustrated by the determination of analyte contents in some animal feeds and water samples from Turkey...
  23. doi request reprint Removal of Pb(II) ions from aqueous solution by a waste mud from copper mine industry: equilibrium, kinetic and thermodynamic study
    Duygu Ozdes
    Department of Chemistry, Karadeniz Technical University, Faculty of Arts and Sciences, 61080 Trabzon, Turkey
    J Hazard Mater 166:1480-7. 2009
    ..Desorption studies were carried out successfully with diluted HCl solutions. The results indicate that a-WM can be used as an effective and no-cost adsorbent for the treatment of industrial wastewaters contaminated with Pb(II) ions...
  24. doi request reprint Column solid phase extraction of iron(III), copper(II), manganese(II) and lead(II) ions food and water samples on multi-walled carbon nanotubes
    Selin Gollu Ozcan
    Faculty of Science, Department of Chemistry, Hacettepe University, 06532 Ankara, Turkey
    Food Chem Toxicol 48:2401-6. 2010
    ..4 fortified lake water and HR-1 River Sediment certified reference materials. The method was applied to the determination of analyte ions in environmental samples...
  25. ncbi request reprint Solid-phase extraction of Mn(II), Co(II), Ni(II), Cu(II), Cd(II) and Pb(II) ions from environmental samples by flame atomic absorption spectrometry (FAAS)
    Celal Duran
    Department of Chemistry, Faculty of Art and Science, Karadeniz Technical University, 61080 Trabzon, Turkey
    J Hazard Mater 146:347-55. 2007
    ..08-0.26 microg L(-1). The method was validated by analyzing three certified reference materials. The method has been applied for the determination of trace elements in some environmental samples...
  26. ncbi request reprint Pseudomonas aeruginosa immobilized multiwalled carbon nanotubes as biosorbent for heavy metal ions
    Mustafa Tuzen
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250, Tokat, Turkey
    Bioresour Technol 99:1563-70. 2008
    ..The presented biosorption procedure was applied to the determination of analytes in tomato leaves, bovine liver, boiled wheat, canned fish, black tea, lichen and natural water samples...
  27. ncbi request reprint Solid-phase extraction of Fe(III), Pb(II) and Cr(III) in environmental samples on amberlite XAD-7 and their determinations by flame atomic absorption spectrometry
    Umit Divrikli
    Pamukkale University, Faculty of Arts and Science, Department of Chemistry, Denizli 20020, Turkey
    J Hazard Mater 149:331-7. 2007
    ..The presented method was applied to the determination of Fe(III), Pb(II) and Cr(III) in water samples from Denizli, Turkey with good results such as recoveries more than 95%, relative standard deviations below 10%...
  28. doi request reprint Carrier element-free coprecipitation with 3-phenly-4-o-hydroxybenzylidenamino-4,5-dihydro-1,2,4-triazole-5-one for separation/preconcentration of Cr(III), Fe(III), Pb(II) and Zn(II) from aqueous solutions
    Celal Duran
    Department of Chemistry, Faculty of Arts and Sciences, Karadeniz Technical University, Trabzon, Turkey
    J Hazard Mater 167:294-9. 2009
    ..The precision of the method evaluated as relative standard deviation (R.S.D.), was in the range of 3-7% depend on the analytes. The proposed method was successfully applied to environmental samples for the determination of the analytes...
  29. doi request reprint Removal of phenol from aqueous solutions by adsorption onto organomodified Tirebolu bentonite: equilibrium, kinetic and thermodynamic study
    Hasan Basri Senturk
    Department of Chemistry, Karadeniz Technical University, Faculty of Arts and Sciences, 61080 Trabzon, Turkey
    J Hazard Mater 172:353-62. 2009
    ..These parameters indicated that adsorption of phenol onto organobentonite was feasible, spontaneous and exothermic in the temperature range of 0-40 degrees C...
  30. doi request reprint Selective speciation and determination of inorganic arsenic in water, food and biological samples
    Mustafa Tuzen
    Faculty of Science and Arts, Chemistry Department, Gaziosmanpasa University, 60250 Tokat, Turkey
    Food Chem Toxicol 48:41-6. 2010
    ..The accuracy of the method was confirmed with certified reference materials. The method was successively applied for the determination and speciation of inorganic arsenic in water, food and biological samples...
  31. ncbi request reprint Preconcentration of Pb(II), Cr(III), Cu(II), Ni(II) and Cd(II) ions in environmental samples by membrane filtration prior to their flame atomic absorption spectrometric determinations
    Umit Divrikli
    Pamukkale University, Faculty of Arts and Science, Department of Chemistry, 20020 Denizli, Turkey
    J Hazard Mater 145:459-64. 2007
    ..The relative standard deviations of the determinations were below 10%...
  32. ncbi request reprint Separation and enrichment of gold(III) from environmental samples prior to its flame atomic absorption spectrometric determination
    Hasan Basri Senturk
    Department of Chemistry, Faculty of Arts and Sciences, Karadeniz Technical University, 61080 Trabzon, Turkey
    J Hazard Mater 149:317-23. 2007
    ..3 mg g(-1). The validation of the presented procedure was checked by the analysis of CRM-SA-C Sandy Soil certified reference material. The presented procedure was applied to the determination of gold in some environmental samples...
  33. ncbi request reprint Chromium speciation by solid phase extraction on Dowex M 4195 chelating resin and determination by atomic absorption spectrometry
    Kadriye Ozlem Saygi
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    J Hazard Mater 153:1009-14. 2008
    ..In the determinations of chromium species, flame atomic absorption spectrometer was used. The results were checked by using NIST SRM 2711 Montana soil and GBW 07603 Bush branched and leaves...
  34. doi request reprint Solid-phase extraction of copper, iron and zinc ions on Bacillus thuringiensis israelensis loaded on Dowex optipore V-493
    Mustafa Tuzen
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    J Hazard Mater 159:335-41. 2008
    ....
  35. ncbi request reprint A novel method for speciation of chromium: coprecipitation without carrier element by using a triazole derivative
    Celal Duran
    Karadeniz Technical University, Faculty of Arts and Sciences, Department of Chemistry, 61080, Trabzon, Turkey
    J AOAC Int 92:257-62. 2009
    ..The presented procedure was applied for Cr speciation in various solid and liquid samples with successful results...
  36. doi request reprint 3-Ethyl-4-(p-chlorobenzylidenamino-4,5-dihydro-1H-1,2,4-triazol-5-one (EPHBAT) as precipitant for carrier element free coprecipitation and speciation of chromium(III) and chromium(VI)
    Ozgur Dogan Uluozlu
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    J Hazard Mater 172:395-9. 2009
    ..To validate the developed method, the certified reference materials (NIST SRM 1573a and GBW 0703) were analyzed. The method was applied for the speciation of chromium in spiked natural water samples with satisfactory results...
  37. doi request reprint Speciation of Mn(II), Mn(VII) and total manganese in water and food samples by coprecipitation-atomic absorption spectrometry combination
    Demirhan Citak
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    J Hazard Mater 173:773-7. 2010
    ..The procedure was successfully applied to natural waters and food samples...
  38. doi request reprint Determination of As(III) and As(V) species in some natural water and food samples by solid-phase extraction on Streptococcus pyogenes immobilized on Sepabeads SP 70 and hydride generation atomic absorption spectrometry
    Ozgur Dogan Uluozlu
    Gaziosmanpasa University, Faculty of Science and Arts, Department of Chemistry, Tokat, Turkey
    Food Chem Toxicol 48:1393-8. 2010
    ..The procedure was also successfully applied to arsenic speciation and determination of some natural water and food samples...
  39. ncbi request reprint Equilibrium, kinetic and thermodynamic studies of adsorption of Pb(II) from aqueous solution onto Turkish kaolinite clay
    Ahmet Sari
    Department of Chemistry, Gaziosmanpasa University, 60250 Tokat, Turkey
    J Hazard Mater 149:283-91. 2007
    ..Furthermore, the Lagergren-first-order, pseudo-second-order and the intraparticle diffusion models were used to describe the kinetic data. The experimental data fitted well the pseudo-second-order kinetics...
  40. ncbi request reprint Bacillus thuringiensis var. israelensis immobilized on Chromosorb 101: a new solid phase extractant for preconcentration of heavy metal ions in environmental samples
    Durali Mendil
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    J Hazard Mater 150:357-63. 2008
    ..The method was also applied successfully to the determination of analytes in microwave digested red wine, rice and canned fish samples and sea water, spring water and urine samples...
  41. ncbi request reprint Biosorption of Pb(II) and Cr(III) from aqueous solution by lichen (Parmelina tiliaceae) biomass
    Ozgur Dogan Uluozlu
    Department of Chemistry, Gaziosmanpasa University, 60250 Tokat, Turkey
    Bioresour Technol 99:2972-80. 2008
    ..The results showed that the biosorption processes of both metal ions followed well pseudo-second-order kinetics...
  42. doi request reprint Assessment of trace element contents of chicken products from Turkey
    Ozgur Dogan Uluozlu
    Gaziosmanpasa University, Faculty of Science and Arts, Department of Chemistry, 60250 Tokat, Turkey
    J Hazard Mater 163:982-7. 2009
    ..02 microg/g for cobalt, 0.10-1.90 microg/g for aluminium, 1.21-24.3 microg/g for zinc, 2.91-155 microg/g for iron. The levels of lead in some analyzed chicken products were higher than the recommended legal limits for human consumption...
  43. doi request reprint Biosorptive removal of mercury(II) from aqueous solution using lichen (Xanthoparmelia conspersa) biomass: kinetic and equilibrium studies
    Mustafa Tuzen
    Department of Chemistry, Gaziosmanpasa University, 60250 Tokat, Turkey
    J Hazard Mater 169:263-70. 2009
    ..Furthermore, the lichen biomass could be regenerated using 1M HCl, with up to 85% recovery, which allowed the reuse of the biomass in ten biosorption-desorption cycles without any considerable loss of biosorptive removal capacity...
  44. doi request reprint Mercury(II) and methyl mercury speciation on Streptococcus pyogenes loaded Dowex Optipore SD-2
    Mustafa Tuzen
    Chemistry Department, Faculty of Science and Arts, Gaziosmanpasa University, 60250 Tokat, Turkey
    J Hazard Mater 169:345-50. 2009
    ..The procedure was successfully applied to the speciation of mercury(II) and methyl mercury in natural water and environmental samples...
  45. doi request reprint Development of a coprecipitation system for the speciation/preconcentration of chromium in tap waters
    Aslihan Karatepe
    Nevsehir University, Faculty of Science and Arts, Department of Chemistry, 50000 Nevsehir, Turkey
    J Hazard Mater 173:433-7. 2010
    ..The detection limits (k=3, N=15) were 0.65 microg/L for chromium(III) and 0.78 microg/L for chromium(VI). The validation of the presented method was checked by the analysis of certified reference materials...
  46. doi request reprint Selective extraction of chromium(VI) using a leaching procedure with sodium carbonate from some plant leaves, soil and sediment samples
    Latif Elci
    Department of Chemistry, Pamukkale University, 20017 Denizli, Turkey
    J Hazard Mater 173:778-82. 2010
    ..93 microg L(-1). The procedure was applied to environmental samples. The relative standard deviation, R.S.D. as precision for 10 replicate measurements of 20 microL(-1) Cr in processed soil sample was 4.2%...
  47. doi request reprint Seasonal investigation of trace element contents in commercially valuable fish species from the Black sea, Turkey
    Durali Mendil
    Faculty of Science and Arts, Chemistry Department, Gaziosmanpasa University, 60250 Tokat, Turkey
    Food Chem Toxicol 48:865-70. 2010
    ..Trace element levels in analyzed fish species were acceptable to human consumption at nutritional and toxic levels. The levels of lead and cadmium in fish samples were higher than the recommended legal limits...
  48. doi request reprint Trace element concentrations of some pet foods commercially available in Turkey
    Ali Duran
    Faculty of Science and Arts, Chemistry Department, Gaziosmanpasa University, 60250 Tokat, Turkey
    Food Chem Toxicol 48:2833-7. 2010
    ..6, 5.78-19.7, 1.66-15.5, 23.9-71.1, 3.28-24.4, 0.58-3.73, and 0.60-2.47 μg/g for Cu, Ni, Pb, Fe, Mn, Cr, and Cd, respectively. The correlation test was also performed to investigate correlations between the metal contents in samples...
  49. doi request reprint Graphite furnace atomic absorption spectrometric detection of vanadium in water and food samples after solid phase extraction on multiwalled carbon nanotubes
    Sham Kumar Wadhwa
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080, Pakistan
    Talanta 116:205-9. 2013
    ..The procedure was also successfully applied to microwave digested food samples including black tea, coffee, tomato, cabbage, zucchini, apple and chicken samples...
  50. doi request reprint Selective speciation of inorganic antimony on tetraethylenepentamine bonded silica gel column and its determination by graphite furnace atomic absorption spectrometry
    Durali Mendil
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    Talanta 107:162-6. 2013
    ..Total antimony was determined in refined salt, unrefined salt, black tea, rice, tuna fish and soil samples after microwave digestion and presented enrichment method combination...
  51. ncbi request reprint Speciation of Cr(III) and Cr(VI) in environmental samples by solid phase extraction on Ambersorb 563 resin
    Ibrahim Narin
    Erciyes University, Faculty of Pharmacy, 38039 Kayseri, Turkey
    J Hazard Mater 136:579-84. 2006
    ..The presented procedure was successfully applied for the chromium speciation in various environmental samples with successfully results...
  52. ncbi request reprint Adsorption of Pb(II) and Cr(III) from aqueous solution on Celtek clay
    Ahmet Sari
    Department of Chemistry, Gaziosmanpasa University, 60250 Tokat, Turkey
    J Hazard Mater 144:41-6. 2007
    ..Based on the results, it was concluded that Celtek clay had a significant potential for removing Pb(II) and Cr(III) from wastewater using adsorption method...
  53. ncbi request reprint Adsorption characteristics of Cu(II) and Pb(II) onto expanded perlite from aqueous solution
    Ahmet Sari
    Department of Chemistry, Gaziosmanpasa University, 60250 Tokat, Turkey
    J Hazard Mater 148:387-94. 2007
    ..Experimental data were also evaluated in terms of kinetic characteristics of adsorption and it was found that adsorption process for both metal ions followed well pseudo-second-order kinetics...
  54. doi request reprint Coprecipitation of Ni(2+), Cd(2+) and Pb(2+) for preconcentration in environmental samples prior to flame atomic absorption spectrometric determinations
    Mustafa Soylak
    Erciyes University, Faculty of Art and Science, Department of Chemistry, 38039 Kayseri, Turkey
    J Hazard Mater 159:435-9. 2008
    ..0, 3.0 and 2.0 microg/L, respectively. The proposed method has been successfully applied for the determination of traces of Ni, Cd and Pb in environmental samples like tap water...
  55. doi request reprint Biosorption of palladium(II) from aqueous solution by moss (Racomitrium lanuginosum) biomass: equilibrium, kinetic and thermodynamic studies
    Ahmet Sari
    Department of Chemistry, Gaziosmanpasa University, Tokat 60250, Turkey
    J Hazard Mater 162:874-9. 2009
    ..Experimental data were also tested using the biosorption kinetic models. The results showed that the biosorption processes of Pd(II) on R. lanuginosum followed well pseudo-second-order kinetics at 20-50 degrees C (R(2)=0.999)...
  56. doi request reprint Column solid-phase extraction of nickel and silver in environmental samples prior to their flame atomic absorption spectrometric determinations
    Mustafa Tuzen
    Chemistry Department, Faculty of Science and Arts, Gaziosmanpasa University, Tokat, Turkey
    J Hazard Mater 164:1428-32. 2009
    ..The proposed enrichment-separation procedure was successfully applied to the determination of analytes in natural water, black tea, tobacco, soil and sediment samples with satisfactory results...
  57. doi request reprint Characterization of biosorption process of As(III) on green algae Ulothrix cylindricum
    Mustafa Tuzen
    Department of Chemistry, Gaziosmanpasa University, Tokat, Turkey
    J Hazard Mater 165:566-72. 2009
    ..Experimental data were also tested in terms of biosorption kinetics using pseudo-first-order and pseudo-second-order kinetic models. The results showed that the biosorption processes of As(III) followed well pseudo-second-order kinetics...
  58. doi request reprint Assessment of trace metal levels in some moss and lichen samples collected from near the motorway in Turkey
    Durali Mendil
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    J Hazard Mater 166:1344-50. 2009
    ..8 microg/g (Cr), 25.6 microg/g (Cu) and 1.5 microg/g (Cd) microg/g for lichens. The concentration of trace metals in samples is depended on moss and lichen species. Some species is accumulated trace metals at high ratio...
  59. doi request reprint Mercury(II) and methyl mercury determinations in water and fish samples by using solid phase extraction and cold vapour atomic absorption spectrometry combination
    Mustafa Tuzen
    Chemistry Department, Faculty of Science and Arts, Gaziosmanpasa University, 60250 Tokat, Turkey
    Food Chem Toxicol 47:1648-52. 2009
    ..The speciation procedure established was successfully applied to the speciation of mercury(II) and methyl mercury in natural water and microwave digested fish samples...
  60. doi request reprint Coprecipitation of trace elements with Ni2+/2-Nitroso-1-naphthol-4-sulfonic acid and their determination by flame atomic absorption spectrometry
    Ozgur Dogan Uluozlu
    Gaziosmanpasa University, Faculty of Science and Arts, Department of Chemistry, 60250, Tokat, Turkey
    J Hazard Mater 176:1032-7. 2010
    ..The presented coprecipitation procedure was successfully applied to some environmental samples for determination of analyte ions...
  61. doi request reprint Determination of trace metals in different fish species and sediments from the River Yeşilirmak in Tokat, Turkey
    Durali Mendil
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, Tokat, Turkey
    Food Chem Toxicol 48:1383-92. 2010
    ..5 microg/g for Zn, 38.7 microg/g for Cu, 17.3 microg/g for Pb, 79.2 microg/g for Ni and 0.55 microg/g for Cd, respectively. Some species is accumulated trace metals at high ratio...
  62. ncbi request reprint Cloud point extraction and flame atomic absorption spectrometry determination of lead (II) in environmental and food samples
    Mustafa Soylak
    University of Erciyes, Chemistry Department, 38039 Kayseri, Turkey
    J AOAC Int 95:1797-802. 2012
    ..An LOD of 1.9 ng/mL along with a preconcentration factor of 50 with RSD of 1.0% for Pb2+ were achieved. The proposed procedure was applied to the analysis of various real samples...
  63. doi request reprint Simultaneous coprecipitation of lead, cobalt, copper, cadmium, iron and nickel in food samples with zirconium(IV) hydroxide prior to their flame atomic absorption spectrometric determination
    Demirhan Citak
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, Tokat, Turkey
    Food Chem Toxicol 47:2302-7. 2009
    ..The procedure was successfully applied to natural waters and food samples like coffee, fish, tobacco, black and green tea...
  64. ncbi request reprint Enrichment/separation of cadmium(II) and lead(II) in environmental samples by solid phase extraction
    Mustafa Tuzen
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    J Hazard Mater 121:79-87. 2005
    ..The preconcentration procedure was applied for the lead and cadmium contents of the natural water samples, some salts with satisfactory results (recoveries >95%, relative standard deviations <8%)...
  65. ncbi request reprint Determination of total chromium by flame atomic absorption spectrometry after coprecipitation by cerium (IV) hydroxide
    Umit Divrikli
    Fen Edebiyat Fakultesi, Pamukkale Universitesi, Kimya Bolumu, 20020, Denizli, Turkey
    Environ Monit Assess 138:167-72. 2008
    ..The analytical results obtained by the proposed method for certified copper sample was in good agreement with the certified value...
  66. ncbi request reprint SP70-alpha-benzoin oxime chelating resin for preconcentration-separation of Pb(II), Cd(II), Co(II) and Cr(III) in environmental samples
    Ibrahim Narin
    Erciyes University, Faculty of Pharmacy, Kayseri 38039, Turkey
    J Hazard Mater 145:113-9. 2007
    ..The optimized method was validated with certified reference materials and successfully applied to the waters, crops and pharmaceutical samples with good results (recoveries greater than 95%, R.S.D. lower than 10%)...
  67. doi request reprint A preconcentration system for determination of copper and nickel in water and food samples employing flame atomic absorption spectrometry
    Mustafa Tuzen
    Department of Chemistry, Gaziosmanpasa University, 60250 Tokat, Turkey
    J Hazard Mater 162:1041-5. 2009
    ..The developed method was successfully applied for the determination of copper and nickel in real samples including human hair, chicken meat, black tea and canned fish...
  68. doi request reprint Ligandless cloud point extraction of Cr(III), Pb(II), Cu(II), Ni(II), Bi(III), and Cd(II) ions in environmental samples with Tween 80 and flame atomic absorption spectrometric determination
    Secil Candir
    Erciyes University, Institute of Health Sciences, Department of Analytical Chemistry, 38039 Kayseri, Turkey
    Talanta 77:289-93. 2008
    ..The detection limits of proposed method were calculated 2.8, 7.2, 0.4, 1.1, 0.8 and 1.7 microg L(-1) for Cr(III), Pb(II), Cu(II), Ni(II), Bi(III), and Cd(II), respectively...
  69. doi request reprint Separation, preconcentration and inductively coupled plasma-mass spectrometric (ICP-MS) determination of thorium(IV), titanium(IV), iron(III), lead(II) and chromium(III) on 2-nitroso-1-naphthol impregnated MCI GEL CHP20P resin
    Funda Armagan Aydin
    Erciyes University, Faculty of Art and Science, Department of Chemistry, 38039 Kayseri, Turkey
    J Hazard Mater 173:669-74. 2010
    ..The separation procedure presented was also applied to the various natural water samples collected from Turkey with satisfactory results...
  70. doi request reprint Carrier element-free coprecipitation (CEFC) method for separation and pre-concentration of some metal ions in natural water and soil samples
    Sibel Saracoglu
    Erciyes University, Faculty of Education, 38039 Kayseri, Turkey
    Food Chem Toxicol 48:1328-33. 2010
    ..In order to support the accuracy of the method, the certified reference materials (BCR 141 R calcareous loam soil and CRM025-050 soil) were analyzed. The experimental results are in good agreement with the certified values...
  71. ncbi request reprint Solid-phase extraction of some heavy metal ions on a double-walled carbon nanotube disk and determination by flame atomic absorption spectrometry
    Aslihan Karatepe
    Nevsehir University, Faculty of Arts and Science, Department of Chemistry, 50300 Nevsehir, Turkey
    J AOAC Int 94:1617-24. 2011
    ..The retained metal ions were eluted by 2 M HNO3. The LOD values for the analytes were in the range of 0.7-4.4 microg/mL. Natural water samples and standard reference materials were analyzed by the presented method...
  72. ncbi request reprint Extractable trace metals content of dust from vehicle air filters as determined by sequential extraction and flame atomic absorption spectrometry
    Sibel Saracoglu
    Erciyes University, Faculty of Education, 38039 Kayseri, Turkey
    J AOAC Int 92:1196-202. 2009
    ..The mean values of Cd, Cu, Fe, and Mn were found to be 15.58, 33.54, 1625, and 180 microg/g, respectively. The results obtained are in agreement with data reported in the literature...
  73. ncbi request reprint Celtek clay as sorbent for separation-preconcentration of metal ions from environmental samples
    Mustafa Tuzen
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    J Hazard Mater 136:597-603. 2006
    ..s.d.'s<10%)...
  74. ncbi request reprint Separation/preconcentration of silver(I) and lead(II) in environmental samples on cellulose nitrate membrane filter prior to their flame atomic absorption spectrometric determinations
    Mustafa Soylak
    Erciyes University, Faculty of Art and Science, Department of Chemistry, 38039 Kayseri, Turkey
    J Hazard Mater 146:142-7. 2007
    ..The relative standard deviations (R.S.D.) of the determinations for analyte ions were below 3%. The method was applied to environmental samples for the determination of analyte ions with satisfactory results (recoveries>95%)...
  75. ncbi request reprint Comparison of sample preparation procedures for the determination of trace heavy metals in house dust, tobacco and tea samples by atomic absorption spectrometry
    Ibrahim Narin
    Nigde University, Faculty of Art and Science, Department of Chemistry, 51100, Nigde, Turkey
    Ann Chim 94:867-73. 2004
    ..The digestions of HNO3/H2SO4/HClO4 (4: 1: 1) mixture for house dust, HNO3/H2SO4/H2O2 (2: 2: 2) mixture for tea and HNO3/H2O2 (4: 2) mixture for tobacco were very efficient...
  76. ncbi request reprint Solid phase extraction of gold(III) on Amberlite XAD-2000 prior to its flame atomic absorption spectrometric determination
    Latif Elci
    Chemistry Department, Faculty of Arts and Sciences, Pamukkale University, 20020 Denizli, Turkey
    Environ Monit Assess 132:331-8. 2007
    ..The relative standard deviation (RSD) was calculated as 3.2% (n = 10). The detection limit for gold was 2 microg l(-1). The accuracy was checked with the determination of gold spiked an artificial seawater and a pure copper samples...
  77. ncbi request reprint A multi-element solid-phase extraction method for trace metals determination in environmental samples on Amberlite XAD-2000
    Volkan Numan Bulut
    Department of Chemistry, Giresun Faculty of Arts and Sciences, Karadeniz Technical University, 28049 Giresun, Turkey
    J Hazard Mater 146:155-63. 2007
    ..45 and 0.25 microg L(-1), respectively. The validation of the procedure was carried out by analysis of certified reference materials. The proposed method was applied to natural waters and kale vegetable (Brassica oleracea var. acephala)...
  78. ncbi request reprint Solid phase extraction method for the determination of iron, lead and chromium by atomic absorption spectrometry using Amberite XAD-2000 column in various water samples
    Latif Elci
    Chemistry Department, Science and Arts Faculty, Pamukkale University, Denizli, Turkey
    J Hazard Mater 153:454-61. 2008
    ..32, 0.51 and 0.81 microg L(-1), for Fe, Pb and Cr, respectively. The procedure was applied to the determination of Fe, Cr and Pb in hot spring water and drinking water samples...
  79. doi request reprint 5-Chloro-2-hydroxyaniline-copper(II) coprecipitation system for preconcentration and separation of lead(II) and chromium(III) at trace levels
    Mustafa Tuzen
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    J Hazard Mater 158:137-41. 2008
    ..The method was successfully applied to the determination of trace lead and chromium in environmental samples...
  80. doi request reprint Trace element content in marine algae species from the Black Sea, Turkey
    Mustafa Tuzen
    Department of Chemistry, Faculty of Science and Arts, Gaziosmanpasa University, 60250, Tokat, Turkey
    Environ Monit Assess 151:363-8. 2009
    ..56-81.9 microg/kg for cobalt. While iron was the highest trace element concentration, cadmium was the lowest in samples. Most of the analyzed samples were edible. The samples are consumed for human diet in several countries...
  81. doi request reprint Preconcentration of some trace elements via using multiwalled carbon nanotubes as solid phase extraction adsorbent
    Ali Duran
    Chemistry Department, Faculty of Science and Arts, Gaziosmanpasa University, 60250 Tokat, Turkey
    J Hazard Mater 169:466-71. 2009
    ..The optimum experimental conditions that ensure the efficiency of the procedure have been investigated and have been successfully applied to the determination of trace elements in environmental samples with satisfactory results...
  82. ncbi request reprint Multiwalled carbon nanotubes for speciation of chromium in environmental samples
    Mustafa Tuzen
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    J Hazard Mater 147:219-25. 2007
    ..The adsorption capacity of multiwalled carbon nanotubes was 9.50 mg g(-1) Cr (VI). The presented method was applied for the speciation of chromium in natural water sample with satisfactory results (recoveries>95%, R.S.D.'s<9%)...
  83. doi request reprint Trace element levels in some dried fruit samples from Turkey
    Ali Duran
    Gaziosmanpasa University, Faculty of Science and Arts, Department of Chemistry, Tokat, Turkey
    Int J Food Sci Nutr 59:581-9. 2008
    ..81 microg/g in white mulberry, highest chromium content was 6.17 microg/g in yellow plum and highest cadmium content was 0.8 microg/g in apricot and rose hip. The results were compared with the literature values...
  84. ncbi request reprint Speciation of antimony using chromosorb 102 resin as a retention medium
    Sibel Saracoglu
    Erciyes University, Art and Sciences Faculty, Chemistry Department, 38039 Kayseri, Turkey
    Anal Sci 19:259-64. 2003
    ..The relative standard deviations were <6%. The procedure was applied to the determination of Sb(III) and Sb(V) in spiked tap water, waste-water samples and a certified copper metal with the satisfactory results...
  85. ncbi request reprint A solid phase extraction procedure for indium prior to its graphite furnace atomic absorption spectrometric determination
    Mustafa Tuzen
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    J Hazard Mater 129:179-85. 2006
    ..The accuracy of procedure was confirmed by indium determination in certified reference materials. The method developed was applied with varying results to the analysis of real samples including metallic zinc with satisfactory results...
  86. ncbi request reprint Chromium speciation in environmental samples by solid phase extraction on Chromosorb 108
    Mustafa Tuzen
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    J Hazard Mater 129:266-73. 2006
    ..The relative errors and relative standard deviations were below 5% and 9%, respectively...
  87. ncbi request reprint Trace metal pollution from traffic in Denizli-Turkey during dry season
    Umit Divrikli
    Pamukkale University, Faculty of Arts and Science, Department of Chemistry, 20020, Denizli, Turkey
    Biomed Environ Sci 19:254-61. 2006
    ..To determine the metal contents of date palm (Pheonix dactylifera) samples in dry season from Denizli-Turkey for investigation of heavy metal-polluted traffic...
  88. ncbi request reprint Cr(VI) and Cr(III) speciation on Bacillus sphaericus loaded diaion SP-850 resin
    Mustafa Tuzen
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    J Hazard Mater 144:549-55. 2007
    ..50 microgL(-1). The procedure was successfully applied to the speciation of chromium(III) and chromium(VI) in natural water samples (R.S.D. lower than 5%, recoveries greater than 95%)...
  89. ncbi request reprint Dysprosium(III) hydroxide coprecipitation system for the separation and preconcentration of heavy metal contents of table salts and natural waters
    Dondu Serpil Kacar Peker
    Erciyes University, Faculty of Art and Science, Department of Chemistry, 38039 Kayseri, Turkey
    J Hazard Mater 143:555-60. 2007
    ..1-25.3 microg/L. The method was applied to the determination of lead, copper, nickel, cobalt, cadmium and manganese ions in natural waters and table salts good results were obtained (relative standard deviations <10%, recoveries >95%)...
  90. ncbi request reprint Copper(II)-8-hydroxquinoline coprecipitation system for preconcentration and separation of cobalt(II) and manganese(II) in real samples
    Mustafa Soylak
    Erciyes University, Faculty of Art and Science, Department of Chemistry, 38039 Kayseri, Turkey
    J Hazard Mater 147:832-7. 2007
    ..The procedure presented was applied to the analyte contents of real samples including natural waters and some food samples with successfully analytical results...
  91. ncbi request reprint Biosorption of copper(II), lead(II), iron(III) and cobalt(II) on Bacillus sphaericus-loaded Diaion SP-850 resin
    Mustafa Tuzen
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    Anal Chim Acta 581:241-6. 2007
    ..The presented method was applied to the determination of analyte ions in green tea, black tea, cultivated mushroom, boiled wheat, rice and soil samples with successfully results...
  92. ncbi request reprint A novel solid phase extraction procedure on Amberlite XAD-1180 for speciation of Cr(III), Cr(VI) and total chromium in environmental and pharmaceutical samples
    Ibrahim Narin
    Erciyes University, Faculty of Pharmacy, 38039 Kayseri, Turkey
    J Hazard Mater 150:453-8. 2008
    ..The procedure was applied to food, water and pharmaceutical samples successfully...
  93. ncbi request reprint Trace metal levels and some chemical parameters in herby cheese collected from south eastern Anatolia-Turkey
    Aydin Vural
    Faculty of Veterinary Medicine, Food Hygiene and Technology Department, Dicle University, 21280 Diyarbakir, Turkey
    Environ Monit Assess 139:27-33. 2008
    ..The mean concentration of lead, copper, cobalt, nickel, chromium and cadmium in our samples are higher than literature values except iron...
  94. ncbi request reprint Trace metal levels in lichen samples from roadsides in East Black Sea region, Turkey
    Ozgur Dogan Uluozlu
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    Biomed Environ Sci 20:203-7. 2007
    ..To determine the metal contents of lichen species from East Black Sea region of Turkey for investigation of trace metal pollution sourced traffic...
  95. ncbi request reprint Simultaneous preconcentration of copper, nickel, cobalt and lead ions prior to their flame atomic absorption spectrometric determination
    Mehrorang Ghaedi
    Chemistry Department, Yasouj University, Yasouj, Iran 75914 353
    Ann Chim 97:277-85. 2007
    ..The detection limits for Cu2+, Ni2+, Co2+ and Pb2+ were 1.6, 1.3, 1.2, 2.3 ng ml(-1), respectively. The method has been successfully applied for these metals content evaluation in some real samples including natural water samples...
  96. ncbi request reprint Solid phase extraction of heavy metal ions in environmental samples on multiwalled carbon nanotubes
    Mustafa Tuzen
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    J Hazard Mater 152:632-9. 2008
    ..The presented method has been applied to the determination of analytes in food and environmental samples with satisfactory results...
  97. ncbi request reprint A biosorption system for metal ions on Penicillium italicum-loaded on Sepabeads SP 70 prior to flame atomic absorption spectrometric determinations
    Durali Mendil
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    J Hazard Mater 152:1171-8. 2008
    ..The method was successfully applied for the determinations of analytes in natural water, cultivated mushroom, lichen (Bryum capilare Hedw), moss (Homalothecium sericeum) and refined table salt samples...
  98. ncbi request reprint Biosorption of aluminum on Pseudomonas aeruginosa loaded on Chromosorb 106 prior to its graphite furnace atomic absorption spectrometric determination
    Mustafa Tuzen
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey
    J Hazard Mater 154:519-25. 2008
    ..The proposed procedure was applied to the determination of aluminum in environmental samples including natural water and food samples. The concentration of aluminum in real samples was found at ppb level...
  99. ncbi request reprint Flame atomic absorption spectrometric determination of trace amounts of heavy metal ions after solid phase extraction using modified sodium dodecyl sulfate coated on alumina
    Mehrorang Ghaedi
    Chemistry Department, Yasouj University, Yasouj 75914 353, Iran
    J Hazard Mater 155:121-7. 2008
    ..The relative standard deviation of the method was found to be less than 3.0%. The presented procedure was successfully applied for determination of analytes in real samples...
  100. doi request reprint Poly(vinyl pyridine-poly ethylene glycol methacrylate-ethylene glycol dimethacrylate) beads for heavy metal removal
    Ali Duran
    Department of Chemical Engineering, Faculty of Engineering, Hacettepe University, 06532 Ankara, Turkey
    J Hazard Mater 155:114-20. 2008
    ..These features show that poly(VP-PEGMA-EGDMA) beads are potential candidate sorbent for heavy metal removal...
  101. doi request reprint Novel solid phase extraction procedure for gold(III) on Dowex M 4195 prior to its flame atomic absorption spectrometric determination
    Mustafa Tuzen
    Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, Tokat, Turkey
    J Hazard Mater 156:591-5. 2008
    ..The adsorption capacity of the resin was 8.1 mg g(-1). The proposed method has been applied for the determination of gold(III) in some real samples including water, soil and sediment samples...