Nomdo M Jansonius

Summary

Affiliation: University Medical Center Groningen
Country: The Netherlands

Publications

  1. doi request reprint Spherical aberration and other higher-order aberrations in the human eye: from summary wave-front analysis data to optical variables relevant to visual perception
    Nomdo M Jansonius
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, P O Box 30 001, 9700 RB Groningen, The Netherlands
    J Opt Soc Am A Opt Image Sci Vis 27:941-50. 2010
  2. pmc A mathematical description of nerve fiber bundle trajectories and their variability in the human retina
    N M Jansonius
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    Vision Res 49:2157-63. 2009
  3. doi request reprint The Groningen Longitudinal Glaucoma Study. II. A prospective comparison of frequency doubling perimetry, the GDx nerve fibre analyser and standard automated perimetry in glaucoma suspect patients
    Nomdo M Jansonius
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    Acta Ophthalmol 87:429-32. 2009
  4. ncbi request reprint Towards an optimal perimetric strategy for progression detection in glaucoma: from fixed-space to adaptive inter-test intervals
    Nomdo M Jansonius
    Department of Ophthalmology, University of Groningen Medical Center, P O Box 30 001, 9700 RB, Groningen, The Netherlands
    Graefes Arch Clin Exp Ophthalmol 244:390-3. 2006
  5. ncbi request reprint Progression detection in glaucoma can be made more efficient by using a variable interval between successive visual field tests
    Nomdo M Jansonius
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    Graefes Arch Clin Exp Ophthalmol 245:1647-51. 2007
  6. ncbi request reprint Strategies for improving the diagnostic specificity of the frequency doubling perimeter
    Govert P Heeg
    Department of Ophthalmology, University Hospital Groningen, 9700 RB Groningen, The Netherlands
    Acta Ophthalmol Scand 83:53-6. 2005
  7. doi request reprint Antithrombotic medication and incident open-angle glaucoma
    Michael W Marcus
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    Invest Ophthalmol Vis Sci 53:3801-5. 2012
  8. doi request reprint Straylight measurements in pseudophakic eyes with natural and dilated pupils: one-year follow-up
    Kim W van Gaalen
    Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    J Cataract Refract Surg 36:923-8. 2010
  9. doi request reprint Corticosteroids and open-angle glaucoma in the elderly: a population-based cohort study
    Michael W Marcus
    Department of Ophthalmology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
    Drugs Aging 29:963-70. 2012
  10. doi request reprint Topical beta-blockers and mortality
    Rogier P H M Müskens
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    Ophthalmology 115:2037-43. 2008

Collaborators

Detail Information

Publications47

  1. doi request reprint Spherical aberration and other higher-order aberrations in the human eye: from summary wave-front analysis data to optical variables relevant to visual perception
    Nomdo M Jansonius
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, P O Box 30 001, 9700 RB Groningen, The Netherlands
    J Opt Soc Am A Opt Image Sci Vis 27:941-50. 2010
    ..The applicability of the method was illustrated by applying the method to wave-front analysis measurements performed in pseudophakic patients with aspheric and spherical intraocular lenses...
  2. pmc A mathematical description of nerve fiber bundle trajectories and their variability in the human retina
    N M Jansonius
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    Vision Res 49:2157-63. 2009
    ..8 degrees ...
  3. doi request reprint The Groningen Longitudinal Glaucoma Study. II. A prospective comparison of frequency doubling perimetry, the GDx nerve fibre analyser and standard automated perimetry in glaucoma suspect patients
    Nomdo M Jansonius
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    Acta Ophthalmol 87:429-32. 2009
    ....
  4. ncbi request reprint Towards an optimal perimetric strategy for progression detection in glaucoma: from fixed-space to adaptive inter-test intervals
    Nomdo M Jansonius
    Department of Ophthalmology, University of Groningen Medical Center, P O Box 30 001, 9700 RB, Groningen, The Netherlands
    Graefes Arch Clin Exp Ophthalmol 244:390-3. 2006
    ..The aim was to compare two perimetric strategies for progression detection in glaucoma...
  5. ncbi request reprint Progression detection in glaucoma can be made more efficient by using a variable interval between successive visual field tests
    Nomdo M Jansonius
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    Graefes Arch Clin Exp Ophthalmol 245:1647-51. 2007
    ..This study aimed to gain insight into the optimal spacing in time for visual field tests for progression detection in glaucoma...
  6. ncbi request reprint Strategies for improving the diagnostic specificity of the frequency doubling perimeter
    Govert P Heeg
    Department of Ophthalmology, University Hospital Groningen, 9700 RB Groningen, The Netherlands
    Acta Ophthalmol Scand 83:53-6. 2005
    ..To evaluate various strategies designed to improve the specificity of the interpretation of results obtained with the frequency doubling technology perimeter (FDT) used in the full-threshold mode...
  7. doi request reprint Antithrombotic medication and incident open-angle glaucoma
    Michael W Marcus
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    Invest Ophthalmol Vis Sci 53:3801-5. 2012
    ..To determine the associations between the use of antithrombotic drugs and incident open-angle glaucoma (OAG)...
  8. doi request reprint Straylight measurements in pseudophakic eyes with natural and dilated pupils: one-year follow-up
    Kim W van Gaalen
    Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    J Cataract Refract Surg 36:923-8. 2010
    ..To compare the amount of straylight in natural pupils and dilated pupils in pseudophakic eyes 6 weeks and 1 year after cataract extraction...
  9. doi request reprint Corticosteroids and open-angle glaucoma in the elderly: a population-based cohort study
    Michael W Marcus
    Department of Ophthalmology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
    Drugs Aging 29:963-70. 2012
    ..It is largely unknown if corticosteroid-induced open-angle glaucoma (OAG) is an entity that is limited to a few susceptible individuals or whether it contributes significantly to the overall population burden of OAG...
  10. doi request reprint Topical beta-blockers and mortality
    Rogier P H M Müskens
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    Ophthalmology 115:2037-43. 2008
    ..To study the associations between long-term and short-term use of topical beta-blockers and mortality...
  11. pmc Population-based evaluation of retinal nerve fiber layer, retinal ganglion cell layer, and inner plexiform layer as a diagnostic tool for glaucoma
    Henriët Springelkamp
    Department of Ophthalmology, Erasmus Medical Center, Rotterdam, The Netherlands Department of Epidemiology, Erasmus Medical Center, Rotterdam, The Netherlands
    Invest Ophthalmol Vis Sci 55:8428-38. 2014
    ..We determined the glaucoma screening performance of regional optical coherence tomography (OCT) layer thickness measurements in the peripapillary and macular region, in a population-based setting...
  12. doi request reprint Risk factors for visual field progression in the groningen longitudinal glaucoma study: a comparison of different statistical approaches
    Christiaan Wesselink
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    J Glaucoma 21:579-85. 2012
    ..To identify risk factors for visual field progression in glaucoma and to compare different statistical approaches with this risk factor analysis...
  13. pmc Optimizing the information yield of 3-D OCT in glaucoma
    Henriët Springelkamp
    Department of Ophthalmology, Erasmus Medical Center, Rotterdam, The Netherlands
    Invest Ophthalmol Vis Sci 53:8162-71. 2012
    ....
  14. doi request reprint Influence of multifocal intraocular lenses on standard automated perimetry test results
    Nancy Aychoua
    Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    JAMA Ophthalmol 131:481-5. 2013
    ..A multifocal intraocular lens (MFIOL) allows for spectacle independence after cataract surgery and is thus a seemingly attractive option. However, several optical limitations have been reported or can be hypothesized...
  15. pmc Cholesterol-lowering drugs and incident open-angle glaucoma: a population-based cohort study
    Michael W Marcus
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    PLoS ONE 7:e29724. 2012
    ..Earlier studies reported cholesterol-lowering drugs to have neuroprotective properties. The aim of this study was to determine the associations between the use of cholesterol-lowering drugs and incident OAG...
  16. ncbi request reprint Influence of test reliability on the screening performance of frequency-doubling perimetry
    Govert P Heeg
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, 9700 RB Groningen, The Netherlands
    Am J Ophthalmol 141:585-7. 2006
    ..To investigate the influence of test reliability on the screening performance of frequency-doubling perimetry (FDT)...
  17. doi request reprint Glaucoma monitoring in a clinical setting: glaucoma progression analysis vs nonparametric progression analysis in the Groningen Longitudinal Glaucoma Study
    Christiaan Wesselink
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    Arch Ophthalmol 127:270-4. 2009
    ....
  18. doi request reprint Glaucoma screening during regular optician visits: the feasibility and specificity of screening in real life
    Margriet M De Vries
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, 9700 R B Groningen, The Netherlands
    Acta Ophthalmol 90:115-21. 2012
    ..To determine the feasibility and specificity of glaucoma screening during regular optician visits...
  19. ncbi request reprint An evaluation of algorithms designed to classify the results from frequency doubling perimetry
    Rogier P H M Müskens
    Department of Ophthalmology, University Hospital Groningen, P O Box 30 001, 9700 RB Groningen, The Netherlands
    Ophthalmic Physiol Opt 24:498-503. 2004
    ..For this algorithm, we found a sensitivity of 0.90 and a specificity of 0.81 at a cut-off point of >1 defect, and an area under the ROC curve of 0.92...
  20. doi request reprint Automated morphometry of the visual pathway in primary open-angle glaucoma
    Aditya T Hernowo
    Laboratory for Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    Invest Ophthalmol Vis Sci 52:2758-66. 2011
    ..To establish whether primary open-angle glaucoma (POAG) is associated with a change in volume of the visual pathway structures between the eyes and the visual cortex...
  21. doi request reprint Factors that influence standard automated perimetry test results in glaucoma: test reliability, technician experience, time of day, and season
    Francisco G Junoy Montolio
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    Invest Ophthalmol Vis Sci 53:7010-7. 2012
    ..To determine the influence of several factors on standard automated perimetry test results in glaucoma...
  22. ncbi request reprint The Groningen Longitudinal Glaucoma Study. I. Baseline sensitivity and specificity of the frequency doubling perimeter and the GDx nerve fibre analyser
    Govert P Heeg
    Department of Ophthalmology, University Hospital Groningen, 9700 RB Groningen, The Netherlands
    Acta Ophthalmol Scand 83:46-52. 2005
    ....
  23. ncbi request reprint Bayes' theorem applied to perimetric progression detection in glaucoma: from specificity to positive predictive value
    Nomdo M Jansonius
    Department of Ophthalmology, University Hospital Groningen, P O Box 30 001, 9700 RB Groningen, The Netherlands
    Graefes Arch Clin Exp Ophthalmol 243:433-7. 2005
    ..To estimate the specificity of a clinical evaluation of a series of visual fields and to calculate the positive predictive value of progression...
  24. doi request reprint A mathematical model for describing the retinal nerve fiber bundle trajectories in the human eye: average course, variability, and influence of refraction, optic disc size and optic disc position
    Nomdo M Jansonius
    University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
    Exp Eye Res 105:70-8. 2012
    ..Refraction (P = 0.021) and possibly optic disc inclination (P = 0.09) influenced the trajectories in the superior-temporal region...
  25. doi request reprint Clinical comparison of the optical performance of aspheric and spherical intraocular lenses
    Kim W van Gaalen
    Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    J Cataract Refract Surg 36:34-43. 2010
    ..To compare the optical performance of aspheric Tecnis ZA9003 and spherical Sensar AR40e intraocular lenses (IOLs)...
  26. ncbi request reprint Effect of intraocular lens implantation on visual acuity, contrast sensitivity, and depth of focus
    Ying Khay Nio
    Laboratory of Experimental Ophthalmology, University of Groningen, Groningen, The Netherlands
    J Cataract Refract Surg 29:2073-81. 2003
    ..To determine the role of spherical and irregular aberrations in the optics of the natural eye and after intraocular lens (IOL) implantation in terms of visual acuity, contrast sensitivity, and depth of focus...
  27. pmc Persistence, spatial distribution and implications for progression detection of blind parts of the visual field in glaucoma: a clinical cohort study
    Francisco G Junoy Montolio
    Dept of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    PLoS ONE 7:e41211. 2012
    ....
  28. ncbi request reprint Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry*
    Liane H van der Jagt
    Department of Ophthalmology, University of Groningen Medical Center, PO Box 30 001, 9700 RB Groningen, The Netherlands
    Ophthalmic Physiol Opt 25:429-35. 2005
    ..Corneal thickness could not explain the differences between an IOP measured with the portable tonometers and an IOP measured with the Goldmann tonometer. Patient comfort was slightly higher for ICARE when compared with the Tonopen...
  29. ncbi request reprint Frequency doubling perimetry screening mode compared to the full-threshold mode
    Remco Stoutenbeek
    Department of Ophthalmology, University Hospital Groningen, P O Box 30 001, 9700 RB Groningen, The Netherlands
    Ophthalmic Physiol Opt 24:493-7. 2004
    ..For the screening mode, we found a sensitivity of 0.91 and a specificity of 0.88 at a cut-off point of >0 defects, and an area under the ROC curve of 0.93...
  30. doi request reprint Glaucoma drainage device surgery after vitreoretinal surgery: incidence and risk factors
    Margriet M De Vries
    Department of Ophthalmology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
    Acta Ophthalmol 94:135-9. 2016
    ..Aim of this study was to determine the incidence of and risk factors for medically uncontrollable glaucoma after vitreoretinal surgery...
  31. doi request reprint Influence of the Retinal Blood Vessel Topography on the Variability of the Retinal Nerve Fiber Bundle Trajectories in the Human Retina
    Kunliang Qiu
    Department of Ophthalmology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands 2Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, Shantou, Guangdong Province, Peopl
    Invest Ophthalmol Vis Sci 56:6320-5. 2015
    ..To determine the relationship between the retinal blood vessel topography and the retinal nerve fiber bundle (RNFB) trajectories in the human retina...
  32. doi request reprint Describing the corneal shape after wavefront-optimized photorefractive keratectomy
    Tim de Jong
    MSc MD PhD Department of Ophthalmology, University of Groningen, University Medical Center Groningen, Groningen, Netherlands all authors
    Optom Vis Sci 91:1231-7. 2014
    ..To develop a procedure for describing wavefront-optimized photorefractive keratectomy (PRK) corneas and to characterize PRK-induced changes in shape...
  33. ncbi request reprint Systemic antihypertensive medication and incident open-angle glaucoma
    Rogier P H M Müskens
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
    Ophthalmology 114:2221-6. 2007
    ..To determine the association between systemic antihypertensive medication and incident open-angle glaucoma...
  34. doi request reprint Long-term visual functioning after eclampsia
    Marjon J Wiegman
    School of Behavioral and Cognitive Neurosciences, Department of Obstetrics and Gynecology, Radiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
    Obstet Gynecol 119:959-66. 2012
    ..We hypothesized that formerly eclamptic women may experience impaired vision-related quality of life (QOL) and visual field loss as a result of the presence of such lesions in the cerebral visual areas...
  35. pmc Changes in cortical grey matter density associated with long-standing retinal visual field defects
    Christine C Boucard
    Laboratory for Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    Brain 132:1898-906. 2009
    ..Such degeneration could interfere with therapeutic strategies such as the future application of artificial retinal implants to overcome lesion-induced visual impairment...
  36. doi request reprint Shape of the anterior cornea: comparison of height data from 4 corneal topographers
    Tim de Jong
    From the Department of Ophthalmology de Jong, Koopmans, Jansonius, University Medical Center Groningen, University of Groningen, Groningen, and the Department of Physics and Medical Technology Dubbelman, VU University Medical Center, Amsterdam, Netherlands the National University Ireland Galway Sheehan, Galway, Ireland
    J Cataract Refract Surg 39:1570-80. 2013
    ..To compare the ability of clinical corneal topographers to describe the shape of the anterior cornea for optical modeling...
  37. doi request reprint Tool to estimate optical metrics from summary wave-front analysis data in the human eye
    Nomdo M Jansonius
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    Ophthalmic Physiol Opt 33:35-41. 2013
    ..The aim of this study was to develop a tool that can be used to estimate these metrics from summary wave-front analysis data...
  38. doi request reprint Relationship between contrast sensitivity and spherical aberration: comparison of 7 contrast sensitivity tests with natural and artificial pupils in healthy eyes
    Kim W van Gaalen
    Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    J Cataract Refract Surg 35:47-56. 2009
    ..To find a contrast sensitivity test that can be used clinically to evaluate interventions aimed at minimizing spherical aberration and determine the circumstances under which these tests should be performed...
  39. doi request reprint Myopia as a risk factor for open-angle glaucoma: a systematic review and meta-analysis
    Michael W Marcus
    Department of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    Ophthalmology 118:1989-1994.e2. 2011
    ..To determine the association between myopia and open-angle glaucoma...
  40. ncbi request reprint Learning effect, normal range, and test-retest variability of Frequency Doubling Perimetry as a function of age, perimetric experience, and the presence or absence of glaucoma
    Govert P Heeg
    Department of Ophthalmology, University Hospital Groningen, PO Box 30 001, 9700 RB Groningen, The Netherlands
    Ophthalmic Physiol Opt 23:535-40. 2003
    ..The learning effect for MD (1 dB or less) appeared to be small as compared with both the normal range (about 12 dB) and the test-retest variability (about 3 dB)...
  41. pmc Lateral Inhibition in the Human Visual System in Patients with Glaucoma and Healthy Subjects: A Case-Control Study
    Francisco G Junoy Montolio
    Dept of Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
    PLoS ONE 11:e0151006. 2016
    ..This suggests that the structure-function discrepancy in glaucoma is not related to a decrease in lateral inhibition. ..
  42. doi request reprint From corneal shape to ocular wavefront in eyes with aspheric IOLs: the feasibility of IOL customisation
    Tim de Jong
    Department of Ophthalmology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
    Ophthalmic Physiol Opt 36:43-50. 2016
    ..A reliable prediction is a prerequisite for future IOL customisation...
  43. doi request reprint Visual disturbances in (pre)eclampsia
    Nina M Roos
    Department of Obstetrics and Gynecology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
    Obstet Gynecol Surv 67:242-50. 2012
    ..Affected women can be reassured that most cases are transient...
  44. ncbi request reprint Effect of methods of myopia correction on visual acuity, contrast sensitivity, and depth of focus
    Ying Khay Nio
    Laboratory of Experimental Ophthalmology, University of Groningen, Rotterdam, The Netherlands
    J Cataract Refract Surg 29:2082-95. 2003
    ..To psychophysically measure spherical and irregular aberrations in patients with various types of myopia correction...
  45. ncbi request reprint Incidence of open-angle glaucoma in a general elderly population: the Rotterdam Study
    Simone de Voogd
    Department of Epidemiology and Biostatistics, Erasmus Medical Center, Rotterdam, The Netherlands
    Ophthalmology 112:1487-93. 2005
    ..To determine the incidence of open-angle glaucoma (OAG) in a general elderly white population...
  46. ncbi request reprint Is diabetes mellitus a risk factor for open-angle glaucoma? The Rotterdam Study
    Simone de Voogd
    Department of Epidemiology and Biostatistics, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
    Ophthalmology 113:1827-31. 2006
    ..To investigate whether diabetes mellitus is a risk factor for open-angle glaucoma (OAG)...
  47. doi request reprint Estrogen receptors alpha and beta and the risk of open-angle glaucoma: the Rotterdam Study
    Simone de Voogd
    Department of Epidemiology, Erasmus Medical Center, Rotterdam, The Netherlands
    Arch Ophthalmol 126:110-4. 2008
    ..To investigate whether polymorphisms in the estrogen receptor alpha (ESR1) and beta (ESR2) genes were a risk factor for open-angle glaucoma (OAG)...