A Llobera

Summary

Affiliation: Esfera UAB
Country: Spain

Publications

  1. doi request reprint Enhancement of the response of poly(dimethylsiloxane) hollow prisms through air mirrors for absorbance-based sensing
    A Llobera
    Institut für Mikrotechnik, Technische Universitat Braunschweig, Alte Salzdahlumer Strasse 203, 38124 Braunschweig, Germany
    Talanta 75:473-9. 2008
  2. ncbi request reprint Multiple internal reflection poly(dimethylsiloxane) systems for optical sensing
    A Llobera
    Institut für Mikrotechnik, Technische Universitat Braunschweig, Alte Salzdahlumer Strasse 203, 38124 Braunschweig, Germany
    Lab Chip 7:1560-6. 2007
  3. ncbi request reprint 3-D modulable PDMS-based microlens system
    V J Cadarso
    Institut de Microelectrònica de Barcelona IMB CNM CSIC, Campus UAB 08193 Barcelona, Spain
    Opt Express 16:4918-29. 2008
  4. ncbi request reprint Optimization of poly(dimethylsiloxane) hollow prisms for optical sensing
    A Llobera
    Institut für Mikrotechnik, Technische Universitat Braunschweig, Alte Salzdahlumer Strasse 203, 38124 Braunschweig, Germany
    Lab Chip 5:506-11. 2005
  5. ncbi request reprint Poly(dimethylsiloxane) hollow Abbe prism with microlenses for detection based on absorption and refractive index shift
    A Llobera
    Institut für Mikrotechnik, Technische Universitat Braunschweig, Alte Salzdahlumer Strassee 203, 38124 Braunschweig, Germany
    Lab Chip 4:24-7. 2004

Collaborators

Detail Information

Publications5

  1. doi request reprint Enhancement of the response of poly(dimethylsiloxane) hollow prisms through air mirrors for absorbance-based sensing
    A Llobera
    Institut für Mikrotechnik, Technische Universitat Braunschweig, Alte Salzdahlumer Strasse 203, 38124 Braunschweig, Germany
    Talanta 75:473-9. 2008
    ..32 and 2.49 (depending on the geometry used), respectively when this simple, however effective element is included into the system...
  2. ncbi request reprint Multiple internal reflection poly(dimethylsiloxane) systems for optical sensing
    A Llobera
    Institut für Mikrotechnik, Technische Universitat Braunschweig, Alte Salzdahlumer Strasse 203, 38124 Braunschweig, Germany
    Lab Chip 7:1560-6. 2007
    ..These results confirm the validity of the proposed systems for high sensitivity measurements...
  3. ncbi request reprint 3-D modulable PDMS-based microlens system
    V J Cadarso
    Institut de Microelectrònica de Barcelona IMB CNM CSIC, Campus UAB 08193 Barcelona, Spain
    Opt Express 16:4918-29. 2008
    ..Experimental results confirm the predicted numerical simulations, showing that, when the structure is under stretching conditions, the first focus is virtually invariable whereas the second focus becomes a Sturm zone...
  4. ncbi request reprint Optimization of poly(dimethylsiloxane) hollow prisms for optical sensing
    A Llobera
    Institut für Mikrotechnik, Technische Universitat Braunschweig, Alte Salzdahlumer Strasse 203, 38124 Braunschweig, Germany
    Lab Chip 5:506-11. 2005
    ..Finally, since the change in the fractions of the methylorange as a function of the pH causes a variation of the total absorption of the solution, the hollow prisms have also been used for pH measurements...
  5. ncbi request reprint Poly(dimethylsiloxane) hollow Abbe prism with microlenses for detection based on absorption and refractive index shift
    A Llobera
    Institut für Mikrotechnik, Technische Universitat Braunschweig, Alte Salzdahlumer Strassee 203, 38124 Braunschweig, Germany
    Lab Chip 4:24-7. 2004
    ..The results clearly show the two regions in which the two physical effects are effective...