Thomas Klenzner

Summary

Affiliation: University of Freiburg
Country: Germany

Publications

  1. ncbi request reprint The effect of large single radiation doses on cochlear implant function: implications for radiosurgery
    Thomas Klenzner
    Department of Otorhinolaryngology and Head and Neck Surgery, University Hospital Freiburg, Killianstrasse 5, 79106 Freiburg, Germany
    Eur Arch Otorhinolaryngol 261:251-5. 2004
  2. ncbi request reprint Eccrine porocarcinoma of the ear mimicking basaloid squamous cell carcinoma
    Thomas Klenzner
    Department of Otorhinolaryngology Head and Neck Surgery, University of Freiburg, Killianstrasse 7, 79106 Freiburg, Germany
    Otolaryngol Head Neck Surg 135:158-60. 2006
  3. ncbi request reprint Navigation as a quality management tool in cochlear implant surgery
    Jörg Schipper
    Department of Otorhinolaryngology, Head and Neck Surgery, University of Freiburg Medical School, Killianstrasse 5, 79106 Freiburg, Germany
    J Laryngol Otol 118:764-70. 2004
  4. ncbi request reprint Quality control after cochlear implant surgery by means of rotational tomography
    Antje Aschendorff
    Department of Otorhinolaryngology, University of Freiburg, Freiburg, Germany
    Otol Neurotol 26:34-7. 2005
  5. ncbi request reprint Quality control after insertion of the nucleus contour and contour advance electrode in adults
    Antje Aschendorff
    Department of Otorhinolaryngology, University of Freiburg, Germany
    Ear Hear 28:75S-79S. 2007
  6. ncbi request reprint Deafness after bacterial meningitis: an emergency for early imaging and cochlear implant surgery
    Antje Aschendorff
    Department of Otorhinolaryngology, University of Freiburg, Germany
    Otolaryngol Head Neck Surg 133:995-6. 2005
  7. ncbi request reprint Evaluation of the HiFocus electrode array with positioner in human temporal bones
    Antje Aschendorff
    Department of Otorhinolaryngology Head and Neck Surgery, University Clinic Freiburg, Germany
    J Laryngol Otol 117:527-31. 2003
  8. ncbi request reprint Pneumocele as a rare differential diagnosis in trigeminal irritation
    Felix B Knapp
    Department of Otorhinolaryngology, University of Freiburg, Germany
    Am J Otolaryngol 24:236-8. 2003
  9. ncbi request reprint Residual hearing conservation and electroacoustic stimulation with the nucleus 24 contour advance cochlear implant
    Bernard Fraysse
    Hopital Purpan, Toulouse, France
    Otol Neurotol 27:624-33. 2006
  10. ncbi request reprint The benefits of sequential bilateral cochlear implantation for hearing-impaired children
    Thomas Steffens
    HNO Klinik Universitätsklinikum Regensburg, Germany
    Acta Otolaryngol 128:164-76. 2008

Collaborators

Detail Information

Publications10

  1. ncbi request reprint The effect of large single radiation doses on cochlear implant function: implications for radiosurgery
    Thomas Klenzner
    Department of Otorhinolaryngology and Head and Neck Surgery, University Hospital Freiburg, Killianstrasse 5, 79106 Freiburg, Germany
    Eur Arch Otorhinolaryngol 261:251-5. 2004
    ..The total dose of 42.5 Gy caused no changes with regard to the tested parameters. The risk of implant failure seems to be low for Nucleus 24 k cochlear implants exposed to large single doses of radiation as used in radiosurgery...
  2. ncbi request reprint Eccrine porocarcinoma of the ear mimicking basaloid squamous cell carcinoma
    Thomas Klenzner
    Department of Otorhinolaryngology Head and Neck Surgery, University of Freiburg, Killianstrasse 7, 79106 Freiburg, Germany
    Otolaryngol Head Neck Surg 135:158-60. 2006
  3. ncbi request reprint Navigation as a quality management tool in cochlear implant surgery
    Jörg Schipper
    Department of Otorhinolaryngology, Head and Neck Surgery, University of Freiburg Medical School, Killianstrasse 5, 79106 Freiburg, Germany
    J Laryngol Otol 118:764-70. 2004
    ..More reproducible reference systems are needed if navigated lateral skull base surgery is to be fully relied upon...
  4. ncbi request reprint Quality control after cochlear implant surgery by means of rotational tomography
    Antje Aschendorff
    Department of Otorhinolaryngology, University of Freiburg, Freiburg, Germany
    Otol Neurotol 26:34-7. 2005
    ..To investigate the intracochlear electrode position in using rotational tomography in adult cochlear implant patients...
  5. ncbi request reprint Quality control after insertion of the nucleus contour and contour advance electrode in adults
    Antje Aschendorff
    Department of Otorhinolaryngology, University of Freiburg, Germany
    Ear Hear 28:75S-79S. 2007
    ..To evaluate the quality of insertion of the Nucleus Contour and the newly developed Contour Advance electrode in adult cochlear implant recipients and to compare results of speech performance tests with regard to electrode position...
  6. ncbi request reprint Deafness after bacterial meningitis: an emergency for early imaging and cochlear implant surgery
    Antje Aschendorff
    Department of Otorhinolaryngology, University of Freiburg, Germany
    Otolaryngol Head Neck Surg 133:995-6. 2005
  7. ncbi request reprint Evaluation of the HiFocus electrode array with positioner in human temporal bones
    Antje Aschendorff
    Department of Otorhinolaryngology Head and Neck Surgery, University Clinic Freiburg, Germany
    J Laryngol Otol 117:527-31. 2003
    ..The implication of the results regarding clinical outcome will be discussed...
  8. ncbi request reprint Pneumocele as a rare differential diagnosis in trigeminal irritation
    Felix B Knapp
    Department of Otorhinolaryngology, University of Freiburg, Germany
    Am J Otolaryngol 24:236-8. 2003
    ..Symptoms, diagnostic findings, therapy, possible causes, and pathogenesis are discussed...
  9. ncbi request reprint Residual hearing conservation and electroacoustic stimulation with the nucleus 24 contour advance cochlear implant
    Bernard Fraysse
    Hopital Purpan, Toulouse, France
    Otol Neurotol 27:624-33. 2006
    ..To assess the conservation of residual hearing in recipients of the Nucleus 24 Contour Advance cochlear implant (CI) and the benefits of combined electrical and acoustic stimulation...
  10. ncbi request reprint The benefits of sequential bilateral cochlear implantation for hearing-impaired children
    Thomas Steffens
    HNO Klinik Universitätsklinikum Regensburg, Germany
    Acta Otolaryngol 128:164-76. 2008
    ..Whilst the trend was for shorter inter-implant intervals and longer implant experience to positively impact binaural advantage, we observed no contraindications for binaural advantage...