M Jung

Summary

Affiliation: University of Giessen
Country: Germany

Publications

  1. ncbi request reprint Surface geometry of three packable and one hybrid composite after finishing
    Martin Jung
    Policlinic for Operative and Preventive Dentistry, Justus Liebig University, Giessen, Germany
    Oper Dent 28:53-9. 2003
  2. ncbi request reprint Surface geometry of four nanofiller and one hybrid composite after one-step and multiple-step polishing
    Martin Jung
    Justus Liebig University, Faculty of Dentistry, Policlinic for Operative and Preventive Dentistry, Giessen, Germany
    Oper Dent 32:347-55. 2007
  3. ncbi request reprint Surface roughness and bond strength of enamel to composite
    M Jung
    Department of Operative and Preventive Dentistry, Justus Liebig University, Giessen, Germany
    Dent Mater 15:250-6. 1999
  4. ncbi request reprint Surface texture of four nanofilled and one hybrid composite after finishing
    Martin Jung
    Policlinic for Operative and Preventive Dentistry, Justus Liebig University, Faculty of Dentistry, Giessen, Germany
    Oper Dent 32:45-52. 2007
  5. ncbi request reprint The imaging of root canal obturation using micro-CT
    M Jung
    Polyclinic for Operative and Preventive Dentistry, Faculty of Dentistry, Justus Liebig University, Giessen, Germany
    Int Endod J 38:617-26. 2005
  6. ncbi request reprint Quality of bristle end-rounding on replaceable heads of powered toothbrushes
    Martin Jung
    Polyclinic for Operative and Preventive Dentistry, Faculty of Dentistry, Justus Liebig University Giessen, D 35392 Giessen, Germany
    J Clin Periodontol 32:604-9. 2005
  7. ncbi request reprint Polishing occlusal surfaces of direct Class II composite restorations in vivo
    Martin Jung
    Faculty of Dentistry, Polyclinic for Operative and Preventive Dentistry, Justus Liebig University, Giessen, Germany
    Oper Dent 30:139-46. 2005
  8. ncbi request reprint Finishing and polishing of indirect composite and ceramic inlays in-vivo: occlusal surfaces
    M Jung
    Dental Clinic, Policlinic for Operative and Preventive Dentistry, Justus Liebig University, Giessen, Germany
    Oper Dent 29:131-41. 2004
  9. ncbi request reprint Is surface roughness of resin composites affected by operator's performance?
    Martin Jung
    Justus Liebig University, Faculty of Dentistry, Policlinic for Operative and Preventive Dentistry, Schlangenzahl 14, D 35392 Giessen, Germany
    Am J Dent 21:3-6. 2008
  10. ncbi request reprint Endodontic treatment of dens invaginatus type III with three root canals and open apical foramen
    M Jung
    Policlinic for Operative and Preventive Dentistry, Justus Liebig University, Giessen, Germany
    Int Endod J 37:205-13. 2004

Detail Information

Publications18

  1. ncbi request reprint Surface geometry of three packable and one hybrid composite after finishing
    Martin Jung
    Policlinic for Operative and Preventive Dentistry, Justus Liebig University, Giessen, Germany
    Oper Dent 28:53-9. 2003
    ..001 except for Sure-Fil). With scanning electron microscopy, surface areas with signs of destruction were found after using a 30 microm diamond on Definite specimens...
  2. ncbi request reprint Surface geometry of four nanofiller and one hybrid composite after one-step and multiple-step polishing
    Martin Jung
    Justus Liebig University, Faculty of Dentistry, Policlinic for Operative and Preventive Dentistry, Giessen, Germany
    Oper Dent 32:347-55. 2007
    ..Except for a combination of a 30 microm diamond and OptiShine brushes, which caused severe roughness, all the polishing methods produced surfaces that were significantly smoother than using the Sof-Lex discs...
  3. ncbi request reprint Surface roughness and bond strength of enamel to composite
    M Jung
    Department of Operative and Preventive Dentistry, Justus Liebig University, Giessen, Germany
    Dent Mater 15:250-6. 1999
    ..The aim of the study was to assess the influence of pretreating enamel by different rotary instruments on shear-bond strength of composite to enamel after the acid etch technique...
  4. ncbi request reprint Surface texture of four nanofilled and one hybrid composite after finishing
    Martin Jung
    Policlinic for Operative and Preventive Dentistry, Justus Liebig University, Faculty of Dentistry, Giessen, Germany
    Oper Dent 32:45-52. 2007
    ..Evaluation by SEM revealed that the use of a 30 microm diamond caused detrimental surface alteration on all types of composites. A remarkable number of porosities were detected on 1 of the nanofilled composites...
  5. ncbi request reprint The imaging of root canal obturation using micro-CT
    M Jung
    Polyclinic for Operative and Preventive Dentistry, Faculty of Dentistry, Justus Liebig University, Giessen, Germany
    Int Endod J 38:617-26. 2005
    ..To examine the potential and accuracy of micro-computed tomography (micro-CT) for imaging of filled root canals...
  6. ncbi request reprint Quality of bristle end-rounding on replaceable heads of powered toothbrushes
    Martin Jung
    Polyclinic for Operative and Preventive Dentistry, Faculty of Dentistry, Justus Liebig University Giessen, D 35392 Giessen, Germany
    J Clin Periodontol 32:604-9. 2005
    ..The aim of this study was to evaluate the geometry and the quality of bristle tip-rounding using 14 different heads from powered toothbrushes...
  7. ncbi request reprint Polishing occlusal surfaces of direct Class II composite restorations in vivo
    Martin Jung
    Faculty of Dentistry, Polyclinic for Operative and Preventive Dentistry, Justus Liebig University, Giessen, Germany
    Oper Dent 30:139-46. 2005
    ..008). Qualitative roughness evaluation showed that there were no significant differences among the four polishing methods (p>0.05)...
  8. ncbi request reprint Finishing and polishing of indirect composite and ceramic inlays in-vivo: occlusal surfaces
    M Jung
    Dental Clinic, Policlinic for Operative and Preventive Dentistry, Justus Liebig University, Giessen, Germany
    Oper Dent 29:131-41. 2004
    ..5%-77.3%). Overall, no significant differences were detectable between the methods for finishing and polishing composite inlays and the methods applied to ceramic restorations with respect to roundness of contours and surface roughness...
  9. ncbi request reprint Is surface roughness of resin composites affected by operator's performance?
    Martin Jung
    Justus Liebig University, Faculty of Dentistry, Policlinic for Operative and Preventive Dentistry, Schlangenzahl 14, D 35392 Giessen, Germany
    Am J Dent 21:3-6. 2008
    ..To assess intra-individual and inter-individual differences in applying finishing diamonds and rubber polishers to composite specimens with special reference to surface roughness...
  10. ncbi request reprint Endodontic treatment of dens invaginatus type III with three root canals and open apical foramen
    M Jung
    Policlinic for Operative and Preventive Dentistry, Justus Liebig University, Giessen, Germany
    Int Endod J 37:205-13. 2004
    ..To describe the conservative endodontic treatment and the 1-year follow-up of a permanent maxillary lateral incisor with dens invaginatus...
  11. ncbi request reprint Bristle end rounding of manual toothbrushes and reproducibility of end rounding classification
    Martin Jung
    Department of Operative Dentistry and Endodontics, Dental Clinic, Justus Liebig University, Giessen, Germany
    Am J Dent 16:299-304. 2003
    ..To evaluate the bristle end rounding quality of the toothbrushes selected. Furthermore the reproducibility of the bristle tip classification method was assessed...
  12. ncbi request reprint Surface geometry of three packable and one hybrid composite after polishing
    Martin Jung
    Policlinic for Operative and Preventive Dentistry, Justus Liebig University, Giessen, Germany
    Oper Dent 28:816-24. 2003
    ..The polishing quality of the one-step systems SuperBuff and Diafix-oral was strongly affected by the initial finishing protocol...
  13. ncbi request reprint Finishing and polishing of a hybrid composite and a heat-pressed glass ceramic
    M Jung
    Justus Liebig University, Dental Clinic, Department for Operative and Preventive Dentistry, Giessen, Germany
    Oper Dent 27:175-83. 2002
    ..SEM evaluation largely confirmed the quantitative results. Composite specimens exhibited signs of selective resin matrix removal when the Ceramiste system or the Politip system were used...
  14. ncbi request reprint Dens invaginatus type II: case report with 2-year radiographic follow-up
    Hille Rodekirchen
    Polyclinic for Operative and Preventive Dentistry, Justus Liebig University, Giessen, Germany
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod 102:e121-5. 2006
    ..After two years the tooth showed no signs of pathosis...
  15. ncbi request reprint Comparison of cobalt chromium, ceramic and pyrocarbon hemiprosthesis in a rabbit model: Ceramic leads to more cartilage damage than cobalt chromium
    Martin Jung
    Department of Orthopedic Surgery, University of Heidelberg, Heidelberg, Germany
    J Biomed Mater Res B Appl Biomater 85:427-34. 2008
    ..Further, in vivo experiments are necessary to elucidate the controversial issue of the most suitable material for hemiarthroplasty...
  16. ncbi request reprint Osseointegration and mechanical stability of pyrocarbon and titanium hand implants in a load-bearing in vivo model for small joint arthroplasty
    Wolfgang Daecke
    Department of Orthopaedic Surgery, University of Heidelberg, Heidelberg, Germany
    J Hand Surg Am 31:90-7. 2006
    ..To test the mechanical stability and histologic osseointegration under load-bearing conditions of 2 different materials, pyrocarbon (Py) and titanium (Ti), in a rabbit model...
  17. ncbi request reprint Lunate resection and vascularized Os pisiform transfer in Kienböck's Disease: an average of 10 years of follow-up study after Saffar's procedure
    Wolfgang Daecke
    Department of Orthopaedic Surgery, University of Heidelberg, Heidelberg, Germany
    J Hand Surg Am 30:677-84. 2005
    ..To investigate the long-term results of lunate replacement by vascularized bone transfer in advanced Kienböck's disease...
  18. ncbi request reprint Effects of local application of growth and differentiation factor-5 (GDF-5) in a full-thickness cartilage defect model
    Hans Georg Simank
    Orthopädische Universitätsklinik Heidelberg, Heidelberg, Germany
    Growth Factors 22:35-43. 2004
    ..We assume that recombinant GDF-5 contained on the carrier is probably able to accelerate the regeneration of the osteochondral defect owing to its availability. However, control of the protein delivery may require further investigation...