Jamshid Dehmeshki

Summary

Publications

  1. ncbi request reprint Volumetric quantification of atherosclerotic plaque in CT considering partial volume effect
    Jamshid Dehmeshki
    Medicsight PLC, London, W1J 5AT, UK
    IEEE Trans Med Imaging 26:273-82. 2007
  2. doi request reprint Shape-based computer-aided detection of lung nodules in thoracic CT images
    Xujiong Ye
    Medicsight PLC, London W14 8UD, UK
    IEEE Trans Biomed Eng 56:1810-20. 2009
  3. ncbi request reprint Automated detection of lung nodules in CT images using shape-based genetic algorithm
    Jamshid Dehmeshki
    Medicsight PLC, London, UK
    Comput Med Imaging Graph 31:408-17. 2007
  4. ncbi request reprint Efficient computer-aided detection of ground-glass opacity nodules in thoracic CT images
    Xujiong Ye
    Medicsight PLC, 66 Hammersmith Road, London W14 8UD, UK
    Conf Proc IEEE Eng Med Biol Soc 2007:4449-52. 2007
  5. ncbi request reprint Computer assisted detection software for CT colonography: effect of sphericity filter on performance characteristics for patients with and without fecal tagging
    Jamshid Dehmeshki
    Medicsight PLC, Berkeley Sq, London, UK
    Eur Radiol 17:662-8. 2007

Detail Information

Publications5

  1. ncbi request reprint Volumetric quantification of atherosclerotic plaque in CT considering partial volume effect
    Jamshid Dehmeshki
    Medicsight PLC, London, W1J 5AT, UK
    IEEE Trans Med Imaging 26:273-82. 2007
    ..The high reproducibility of the proposed method for 35 patients, scanned twice using the same protocol at a minimum interval of 10 min, shows that the method provides 2-3 times lower interscan variation than conventional techniques...
  2. doi request reprint Shape-based computer-aided detection of lung nodules in thoracic CT images
    Xujiong Ye
    Medicsight PLC, London W14 8UD, UK
    IEEE Trans Biomed Eng 56:1810-20. 2009
    ..The method's high detection rate, fast computation, and applicability to different imaging conditions and nodule types shows much promise for clinical applications...
  3. ncbi request reprint Automated detection of lung nodules in CT images using shape-based genetic algorithm
    Jamshid Dehmeshki
    Medicsight PLC, London, UK
    Comput Med Imaging Graph 31:408-17. 2007
    ..6/scan (0.06/slice). The high-detection performance of the method suggested promising potential for clinical applications...
  4. ncbi request reprint Efficient computer-aided detection of ground-glass opacity nodules in thoracic CT images
    Xujiong Ye
    Medicsight PLC, 66 Hammersmith Road, London W14 8UD, UK
    Conf Proc IEEE Eng Med Biol Soc 2007:4449-52. 2007
    ..3%, with the number of false positives at approximately 12.7/scan (0.07/slice). The high detection performance of the method suggested promising potential for clinical applications...
  5. ncbi request reprint Computer assisted detection software for CT colonography: effect of sphericity filter on performance characteristics for patients with and without fecal tagging
    Jamshid Dehmeshki
    Medicsight PLC, Berkeley Sq, London, UK
    Eur Radiol 17:662-8. 2007
    ..8% for polyps 6 mm or more when used at a sphericity setting of 0.3. Higher sphericity settings increased specificity while reducing sensitivity. The bowel preparation used significantly impacts on specificity...