David G Silverman

Summary

Affiliation: Yale University
Country: USA

Publications

  1. ncbi The use of joint time frequency analysis to quantify the effect of ventilation on the pulse oximeter waveform
    Kirk H Shelley
    Department of Anesthesiology, Yale University, New Haven, CT 06520 8051, USA
    J Clin Monit Comput 20:81-7. 2006
  2. ncbi What is the best site for measuring the effect of ventilation on the pulse oximeter waveform?
    Kirk H Shelley
    Department of Anesthesiology, Yale University, New Haven, Connecticut, USA
    Anesth Analg 103:372-7, table of contents. 2006
  3. ncbi Modeling perioperative risk: can numbers speak louder than words?
    Natalie F Holt
    Department of Anesthesiology, TMP 3, Yale University School of Medicine, 333 Cedar Street, New Haven CT 06510, USA
    Anesthesiol Clin 24:427-59. 2006
  4. ncbi Rofecoxib does not compromise platelet aggregation during anesthesia and surgery
    David G Silverman
    Departments of Anesthesiology and Laboratory Medicine, Yale University School of Medicine, New Haven, Connecticutt 06520 8051, USA
    Can J Anaesth 50:1004-8. 2003
  5. ncbi Integrated assessment and consultation for the preoperative patient
    David G Silverman
    Department of Anesthesiology, Yale University School of Medicine, Yale New Haven Hospital, New Haven, CT 06510, USA
    Med Clin North Am 93:963-77. 2009
  6. ncbi Impact of central hypovolemia on photoplethysmographic waveform parameters in healthy volunteers part 2: frequency domain analysis
    Aymen A Alian
    Department of Anesthesiology, Yale University School of Medicine, New Haven, CT 06520 8051, USA
    J Clin Monit Comput 25:387-96. 2011
  7. ncbi Survey of anesthesiologists as to the value of prior ECG in a patient with nonspecific ST-T wave changes
    Hossam Tantawy
    Department of Anesthesiology, Yale University School of Medicine, New Haven, CT 06520 8051, USA
    Conn Med 71:453-6. 2007
  8. ncbi Preoperative beta-blocker use: impact of national guidelines on clinical practice
    Shamsuddin Akhtar
    Department of Anesthesiology, Yale University School of Medicine, New Haven, CT 06520 8051, USA
    J Clin Anesth 20:122-8. 2008
  9. ncbi Impact of withdrawal of 450 ml of blood on respiration-induced oscillations of the ear plethysmographic waveform
    Michael J Gesquiere
    Department of Anesthesiology, Yale University School of Medicine, 333 Cedar Street, PO Box 208051, New Haven, CT 06520 8051, USA
    J Clin Monit Comput 21:277-82. 2007
  10. ncbi The relationship between the photoplethysmographic waveform and systemic vascular resistance
    Aymen A Awad
    Department of Anesthesiology, Yale University School of Medicine, 333 Cedar Street, P O Box 208051, New Haven, CT 06520 8051, USA
    J Clin Monit Comput 21:365-72. 2007

Collaborators

Detail Information

Publications22

  1. ncbi The use of joint time frequency analysis to quantify the effect of ventilation on the pulse oximeter waveform
    Kirk H Shelley
    Department of Anesthesiology, Yale University, New Haven, CT 06520 8051, USA
    J Clin Monit Comput 20:81-7. 2006
    ..By analyzing how the frequency spectrum of the pulse oximeter waveform changes over time, new clinically relevant features can be extracted...
  2. ncbi What is the best site for measuring the effect of ventilation on the pulse oximeter waveform?
    Kirk H Shelley
    Department of Anesthesiology, Yale University, New Haven, Connecticut, USA
    Anesth Analg 103:372-7, table of contents. 2006
    ..A significant correlation was demonstrated between the estimated blood loss from surgical procedures and the impact of ventilation on ear plethysmographic data (r(s) = 0.624, P = 0.006)...
  3. ncbi Modeling perioperative risk: can numbers speak louder than words?
    Natalie F Holt
    Department of Anesthesiology, TMP 3, Yale University School of Medicine, 333 Cedar Street, New Haven CT 06510, USA
    Anesthesiol Clin 24:427-59. 2006
    ..The old adage can be modified: "if your patient rates more than two ASPIRIN, call me before the morning (of surgery)."..
  4. ncbi Rofecoxib does not compromise platelet aggregation during anesthesia and surgery
    David G Silverman
    Departments of Anesthesiology and Laboratory Medicine, Yale University School of Medicine, New Haven, Connecticutt 06520 8051, USA
    Can J Anaesth 50:1004-8. 2003
    ....
  5. ncbi Integrated assessment and consultation for the preoperative patient
    David G Silverman
    Department of Anesthesiology, Yale University School of Medicine, Yale New Haven Hospital, New Haven, CT 06510, USA
    Med Clin North Am 93:963-77. 2009
    ....
  6. ncbi Impact of central hypovolemia on photoplethysmographic waveform parameters in healthy volunteers part 2: frequency domain analysis
    Aymen A Alian
    Department of Anesthesiology, Yale University School of Medicine, New Haven, CT 06520 8051, USA
    J Clin Monit Comput 25:387-96. 2011
    ..Lower body negative pressure (LBNP) has been used as an experimental tool to simulate loss of central blood volume in humans. The aim of our research is to understanding PPG waveform changes during progressive hypovolemia...
  7. ncbi Survey of anesthesiologists as to the value of prior ECG in a patient with nonspecific ST-T wave changes
    Hossam Tantawy
    Department of Anesthesiology, Yale University School of Medicine, New Haven, CT 06520 8051, USA
    Conn Med 71:453-6. 2007
    ..We surveyed anesthesiologists to determine if their concern about nonspecific ST-T (NSST) wave changes is influenced significantly by the availability of a prior ECG for comparison...
  8. ncbi Preoperative beta-blocker use: impact of national guidelines on clinical practice
    Shamsuddin Akhtar
    Department of Anesthesiology, Yale University School of Medicine, New Haven, CT 06520 8051, USA
    J Clin Anesth 20:122-8. 2008
    ....
  9. ncbi Impact of withdrawal of 450 ml of blood on respiration-induced oscillations of the ear plethysmographic waveform
    Michael J Gesquiere
    Department of Anesthesiology, Yale University School of Medicine, 333 Cedar Street, PO Box 208051, New Haven, CT 06520 8051, USA
    J Clin Monit Comput 21:277-82. 2007
    ..The present study assessed whether alterations in volume status likewise can be detected with noninvasive monitoring (ear plethysmograph) in non-intubated subjects (awake volunteers)...
  10. ncbi The relationship between the photoplethysmographic waveform and systemic vascular resistance
    Aymen A Awad
    Department of Anesthesiology, Yale University School of Medicine, 333 Cedar Street, P O Box 208051, New Haven, CT 06520 8051, USA
    J Clin Monit Comput 21:365-72. 2007
    ..The objective of this study was to determine the relationship between systemic vascular resistance (SVR), finger & ear photoplethysmographic measurements in 14 adult patients undergoing coronary artery bypass grafting (CABG)...
  11. ncbi Comparing the effect of arginine vasopressin on ear and finger photoplethysmography
    Denis H Jablonka
    Department of Anesthesiology, Yale University, New Haven, CT 06520, USA
    J Clin Anesth 20:90-3. 2008
    ..To test whether the relative insensitivity of craniofacial vessels to catecholamines differs in response to arginine vasopressin...
  12. ncbi Impact of central hypovolemia on photoplethysmographic waveform parameters in healthy volunteers. Part 1: time domain analysis
    Aymen A Alian
    Department of Anesthesiology, Yale University School of Medicine, New Haven, CT 06520 8051, USA
    J Clin Monit Comput 25:377-85. 2011
    ..We hypothesize that during progressive LBNP; there will be a preservation of ear PPG parameters and a decrease in finger PPG parameters...
  13. ncbi Measuring venous oxygenation using the photoplethysmograph waveform
    Zachary D Walton
    Department of Anesthesiology, Yale University School of Medicine, 333 Cedar Street, P O Box 208051, New Haven, CT 06520 8051, USA
    J Clin Monit Comput 24:295-303. 2010
    ..We investigate the hypothesis that the photoplethysmograph (PPG) waveform can be analyzed to infer regional venous oxygen saturation...
  14. ncbi The effect of venous pulsation on the forehead pulse oximeter wave form as a possible source of error in Spo2 calculation
    Kirk H Shelley
    Department of Anesthesiology, Yale University, New Haven, Connecticut, USA
    Anesth Analg 100:743-7, table of contents. 2005
    ..It is believed that the venous wave form is a result of the method of attachment rather than the use of reflective plethysmographic sensors...
  15. ncbi Preanesthesia clinics, information management, and operating room delays: results of a survey of practicing anesthesiologists
    Natalie F Holt
    Department of Anesthesiology, Yale University School of Medicine, New Haven, CT, USA
    Anesth Analg 104:615-8. 2007
    ..In several single-center studies, PECs have been shown to have a positive impact. However, limited information is available regarding their overall use and perceived effectiveness...
  16. ncbi Topical non-iontophoretic application of acetylcholine and nitroglycerin via a translucent patch: a new means for assessing microvascular reactivity
    Robert B Schonberger
    Doris Duke Clinicial Research, Yale University School of Medicine, 333 CedarStreet, New Haven, CT 06510, USA
    Yale J Biol Med 79:1-7. 2006
    ....
  17. ncbi Preoperative beta-blocker use: is titration to a heart rate of 60 beats per minute a consistently attainable goal?
    Shamsuddin Akhtar
    Department of Anesthesiology, Yale University School of Medicine, New Haven, CT 06520 8051, USA
    J Clin Anesth 17:191-7. 2005
    ....
  18. ncbi Optimizing postoperative outcomes with efficient preoperative assessment and management
    Thomas M Halaszynski
    Department of Anesthesiology, Yale University School of Medicine, New Haven, CT, USA
    Crit Care Med 32:S76-86. 2004
    ..The ultimate goal is to provide safe and "efficient" care, without exhausting highly valued intensive care resources...
  19. ncbi Assessment and management of patients with ischemic heart disease
    Shamsuddin Akhtar
    Department of Anesthesiology, Yale University School of Medicine, New Haven, CT, USA
    Crit Care Med 32:S126-36. 2004
    ..Diagnosis and management of perioperative myocardial infarction continues to be a challenge. However, use of cardiac specific biomarkers should improve the diagnostic process...
  20. ncbi Analysis of the ear pulse oximeter waveform
    Aymen A Awad
    Department of Anesthesia, Yale University School of Medicine, New Haven, CT 06516, USA
    J Clin Monit Comput 20:175-84. 2006
    ..CONCLUSION: The ear is relatively immune to vasoconstrictive challenges which make ear plethysmographic waveforms a suitable monitor for central hemodynamic changes. The ear plethysmographic width has a good correlation with CO...
  21. ncbi Tissue Doppler of early mitral filling correlates with simulated volume loss in healthy subjects
    Christopher L Moore
    Department of Emergency Medicine, Yale University School of Medicine, New Haven, CT, USA
    Acad Emerg Med 17:1162-8. 2010
    ....
  22. ncbi Distinction between atropine-sensitive control of microvascular and cardiac oscillatory activity
    David G Silverman
    Department of Anesthesiology, Yale University School of Medicine, 333 Cedar Street, New Haven, Connecticut 06520-8051, USA
    Microvasc Res 63:196-208. 2002
    ....