Sherrod L Maxwell

Summary

Affiliation: Westinghouse Savannah River Company
Country: USA

Publications

  1. ncbi New method for removal of spectral interferences for beryllium assay using inductively coupled plasma atomic emission spectrometry
    Sherrod L Maxwell
    Washington Savannah River Company, Analytical Labs, Building 735 B, Aiken, SC 29808, USA
    Talanta 76:432-40. 2008
  2. ncbi Rapid separation method for actinides in emergency air filter samples
    Sherrod L Maxwell
    Savannah River Nuclear Solutions, LLC, Building 735 B, Aiken, SC 29808, USA
    Appl Radiat Isot 68:2125-31. 2010
  3. ncbi Determination of 237Np and Pu isotopes in large soil samples by inductively coupled plasma mass spectrometry
    Sherrod L Maxwell
    Savannah River Nuclear Solutions, LLC, Building 735 B, Aiken, SC 29808, USA
    Anal Chim Acta 682:130-6. 2010
  4. ncbi Rapid separation method for 237Np and Pu isotopes in large soil samples
    Sherrod L Maxwell
    Savannah River Nuclear Solutions, LLC, Aiken, SC 29808, USA
    Appl Radiat Isot 69:917-23. 2011
  5. ncbi Rapid determination of (237)Np and plutonium isotopes in urine by inductively-coupled plasma mass spectrometry and alpha spectrometry
    Sherrod L Maxwell
    Savannah River Nuclear Solutions, Aiken, SC 29808, USA
    Health Phys 101:180-6. 2011
  6. ncbi Rapid radiochemical method for determination of actinides in emergency concrete and brick samples
    Sherrod L Maxwell
    Savannah River Nuclear Solutions, LLC, Aiken, SC 29808, USA
    Anal Chim Acta 701:112-8. 2011
  7. ncbi Rapid determination of actinides in urine by inductively coupled plasma mass spectrometry and alpha spectrometry: a hybrid approach
    Sherrod L Maxwell
    Savannah River Nuclear Solutions, LLC, Aiken, SC 29808, USA
    Talanta 80:143-50. 2009

Detail Information

Publications7

  1. ncbi New method for removal of spectral interferences for beryllium assay using inductively coupled plasma atomic emission spectrometry
    Sherrod L Maxwell
    Washington Savannah River Company, Analytical Labs, Building 735 B, Aiken, SC 29808, USA
    Talanta 76:432-40. 2008
    ..The effective removal of spectral interferences allows lower method detection limits (MDL) using inductively coupled atomic emission spectrometry. A vacuum box system is employed to reduce analytical time and reduce labor costs...
  2. ncbi Rapid separation method for actinides in emergency air filter samples
    Sherrod L Maxwell
    Savannah River Nuclear Solutions, LLC, Building 735 B, Aiken, SC 29808, USA
    Appl Radiat Isot 68:2125-31. 2010
    ..The actinide and (90)Sr in air filter results were reported in less than 4 h with excellent quality...
  3. ncbi Determination of 237Np and Pu isotopes in large soil samples by inductively coupled plasma mass spectrometry
    Sherrod L Maxwell
    Savannah River Nuclear Solutions, LLC, Building 735 B, Aiken, SC 29808, USA
    Anal Chim Acta 682:130-6. 2010
    ..Alpha spectrometry can also be applied so that the shorter-lived (238)Pu isotope can be measured successfully. (239) Pu, (242)Pu and (237)Np were measured by ICP-MS, while (236)Pu and (238)Pu were measured by alpha spectrometry...
  4. ncbi Rapid separation method for 237Np and Pu isotopes in large soil samples
    Sherrod L Maxwell
    Savannah River Nuclear Solutions, LLC, Aiken, SC 29808, USA
    Appl Radiat Isot 69:917-23. 2011
    ..Vacuum box technology and rapid flow rates are used to reduce analytical time...
  5. ncbi Rapid determination of (237)Np and plutonium isotopes in urine by inductively-coupled plasma mass spectrometry and alpha spectrometry
    Sherrod L Maxwell
    Savannah River Nuclear Solutions, Aiken, SC 29808, USA
    Health Phys 101:180-6. 2011
    ..If UTEVA resin is added to the separation scheme, a decontamination factor of ~3 × 10(6) can be achieved...
  6. ncbi Rapid radiochemical method for determination of actinides in emergency concrete and brick samples
    Sherrod L Maxwell
    Savannah River Nuclear Solutions, LLC, Aiken, SC 29808, USA
    Anal Chim Acta 701:112-8. 2011
    ..The rapid fusion technique is a rugged sample digestion method that ensures that any refractory actinide particles are effectively digested...
  7. ncbi Rapid determination of actinides in urine by inductively coupled plasma mass spectrometry and alpha spectrometry: a hybrid approach
    Sherrod L Maxwell
    Savannah River Nuclear Solutions, LLC, Aiken, SC 29808, USA
    Talanta 80:143-50. 2009
    ....