Jianhua Wang

Summary

Affiliation: University of Miami
Country: USA

Publications

  1. ncbi request reprint Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography
    Jianhua Wang
    Centre for Contact Lens Research, School of Optometry, University of Waterloo, Waterloo, Ontario, Canada
    Invest Ophthalmol Vis Sci 44:2524-8. 2003
  2. pmc Simultaneous real-time imaging of the ocular anterior segment including the ciliary muscle during accommodation
    Yilei Shao
    Bascom Palmer Eye Institute, University of Miami, Miami, FL, 33136, USA School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China These authors contributed equally to this work
    Biomed Opt Express 4:466-80. 2013
  3. pmc Ultra-high resolution optical coherence tomography for monitoring tear meniscus volume in dry eye after topical cyclosporine treatment
    Jianhua Wang
    Bascom Palmer Eye Institute, University of Miami Leonard M Miller School of Medicine, Miami, FL, USA
    Clin Ophthalmol 6:933-8. 2012
  4. doi request reprint Ultra-high resolution optical coherence tomography for imaging the anterior segment of the eye
    Jianhua Wang
    Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, 1638 NW 10th Avenue, Miami, FL 33136, USA
    Ophthalmic Surg Lasers Imaging 42:S15-27. 2011
  5. doi request reprint Dynamic distribution of artificial tears on the ocular surface
    Jianhua Wang
    Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, 1638 NW 10th Ave, McKnight Bldg, Room 506, Miami, FL 33136, USA
    Arch Ophthalmol 126:619-25. 2008
  6. ncbi request reprint Relationships between central tear film thickness and tear menisci of the upper and lower eyelids
    Jianhua Wang
    Department of Ophthalmology, Schepens Eye Research Institute, Harvard Medical School, Boston, MA 02114, USA
    Invest Ophthalmol Vis Sci 47:4349-55. 2006
  7. pmc Detection of magnetic particles in live DBA/2J mouse eyes using magnetomotive optical coherence tomography
    Jianhua Wang
    Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miami, FL, USA
    Eye Contact Lens 36:346-51. 2010
  8. doi request reprint The watery eye
    Jianhua Wang
    Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miami, FL 33136, USA
    Curr Allergy Asthma Rep 11:192-6. 2011
  9. pmc In situ visualization of tears on contact lens using ultra high resolution optical coherence tomography
    Jianhua Wang
    Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, FL 33136, USA
    Eye Contact Lens 35:44-9. 2009
  10. pmc Correlations among upper and lower tear menisci, noninvasive tear break-up time, and the Schirmer test
    Jianhua Wang
    Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miami, Florida 33136, USA
    Am J Ophthalmol 145:795-800. 2008

Research Grants

  1. Characterization of Tear Dynamics
    Jianhua Wang; Fiscal Year: 2007

Collaborators

Detail Information

Publications94

  1. ncbi request reprint Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography
    Jianhua Wang
    Centre for Contact Lens Research, School of Optometry, University of Waterloo, Waterloo, Ontario, Canada
    Invest Ophthalmol Vis Sci 44:2524-8. 2003
    ..To demonstrate the feasibility of indirectly measuring the precorneal tear film thickness and pre- and postlens tear film (PLTF) thickness using optical coherence tomography (OCT)...
  2. pmc Simultaneous real-time imaging of the ocular anterior segment including the ciliary muscle during accommodation
    Yilei Shao
    Bascom Palmer Eye Institute, University of Miami, Miami, FL, 33136, USA School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China These authors contributed equally to this work
    Biomed Opt Express 4:466-80. 2013
    ..The combined system appeared to be capable to simultaneously real-time image the biometry of the anterior segment, including the ciliary muscle, in vivo during accommodation...
  3. pmc Ultra-high resolution optical coherence tomography for monitoring tear meniscus volume in dry eye after topical cyclosporine treatment
    Jianhua Wang
    Bascom Palmer Eye Institute, University of Miami Leonard M Miller School of Medicine, Miami, FL, USA
    Clin Ophthalmol 6:933-8. 2012
    ..This study was designed to determine the ability of ultra-high-resolution optical coherence tomography (UHR-OCT) to monitor tear meniscus volume after dry eye treatment with Restasis(®) (0.05% cyclosporine)...
  4. doi request reprint Ultra-high resolution optical coherence tomography for imaging the anterior segment of the eye
    Jianhua Wang
    Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, 1638 NW 10th Avenue, Miami, FL 33136, USA
    Ophthalmic Surg Lasers Imaging 42:S15-27. 2011
    ..The authors focused on the use of UHR-OCT for imaging of tear dynamics, contact lens interactions with the corneal surface, and in vivo histological diagnosis of disorders of the cornea, as well as the future direction in this field...
  5. doi request reprint Dynamic distribution of artificial tears on the ocular surface
    Jianhua Wang
    Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, 1638 NW 10th Ave, McKnight Bldg, Room 506, Miami, FL 33136, USA
    Arch Ophthalmol 126:619-25. 2008
    ..To study the effects of artificial tear viscosity on tear film thickness, upper and lower tear menisci, and tear volume using optical coherence tomography...
  6. ncbi request reprint Relationships between central tear film thickness and tear menisci of the upper and lower eyelids
    Jianhua Wang
    Department of Ophthalmology, Schepens Eye Research Institute, Harvard Medical School, Boston, MA 02114, USA
    Invest Ophthalmol Vis Sci 47:4349-55. 2006
    ..To investigate the relationship between central tear film thickness (TFT) and tear menisci of the upper and lower eyelids using real-time optical coherence tomography (OCT)...
  7. pmc Detection of magnetic particles in live DBA/2J mouse eyes using magnetomotive optical coherence tomography
    Jianhua Wang
    Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miami, FL, USA
    Eye Contact Lens 36:346-51. 2010
    ..To demonstrate in vivo molecular imaging of the eye using spectral-domain magnetomotive optical coherence tomography (MMOCT)...
  8. doi request reprint The watery eye
    Jianhua Wang
    Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miami, FL 33136, USA
    Curr Allergy Asthma Rep 11:192-6. 2011
    ..Recent advances in imaging technique are briefly discussed...
  9. pmc In situ visualization of tears on contact lens using ultra high resolution optical coherence tomography
    Jianhua Wang
    Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, FL 33136, USA
    Eye Contact Lens 35:44-9. 2009
    ..To demonstrate the capability of directly visualizing the tear film on contact lenses using optical coherence tomography (OCT)...
  10. pmc Correlations among upper and lower tear menisci, noninvasive tear break-up time, and the Schirmer test
    Jianhua Wang
    Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miami, Florida 33136, USA
    Am J Ophthalmol 145:795-800. 2008
    ..To determine the relationships among tear meniscus parameters, noninvasive tear break-up time (NITBUT), and the Schirmer test...
  11. doi request reprint Effect of punctal occlusion on tear menisci in symptomatic contact lens wearers
    Ming Li
    School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical College, Wenzhou, Zhejiang, China
    Cornea 31:1014-22. 2012
    ..To investigate by ultrahigh resolution optical coherence tomography the effect of punctal occlusion on tear menisci in symptomatic and asymptomatic contact lens wearers...
  12. doi request reprint The development of the refractive status and ocular growth in C57BL/6 mice
    Xiangtian Zhou
    School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical College, Wenzhou, Zhejiang, China
    Invest Ophthalmol Vis Sci 49:5208-14. 2008
    ..To investigate refraction, corneal curvature, axial components, and the correlations between the refraction and ocular growth during the emmetropization in the C57BL/6 mouse...
  13. ncbi request reprint Diurnal variation of ocular hysteresis, corneal thickness, and intraocular pressure
    Meixiao Shen
    School of Optometry and Ophthalmology, Eye Hospital, Wenzhou Medical College, Key Laboratory of Vision Science, Ministry of Health PR China, Wenzhou, Zhejiang, China
    Optom Vis Sci 85:1185-92. 2008
    ....
  14. pmc Whole eye axial biometry during accommodation using ultra-long scan depth optical coherence tomography
    Jianguang Zhong
    Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida Hangzhou First People s Hospital, Zhejiang, China
    Am J Ophthalmol 157:1064-69. 2014
    ..To investigate changes of whole eye axial biometry during accommodation using ultra-long scan depth optical coherence tomography (UL-OCT)...
  15. doi request reprint Upper punctal occlusion versus lower punctal occlusion in dry eye
    Feng Chen
    School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China
    Invest Ophthalmol Vis Sci 51:5571-7. 2010
    ..To compare the effectiveness of upper punctal occlusion versus that of lower punctal occlusion in dry eye patients...
  16. pmc Quantitative analysis of the intraretinal layers and optic nerve head using ultra-high resolution optical coherence tomography
    Yuhong Wang
    Wenzhou Medical College, School of Ophthalmology and Optometry, Wenzhou, Zhejiang, China
    J Biomed Opt 17:066013. 2012
    ..47% to 26.20%. With group B, high interclass correlations were found and the automatic segmentation results were compatible with the manual results. Our results indicated that more retinal features might be imageable using UHR-OCT...
  17. pmc Human conjunctival microvasculature assessed with a retinal function imager (RFI)
    Hong Jiang
    Bascom Palmer Eye Institute, University of Miami, Miami, FL 33136, USA
    Microvasc Res 85:134-7. 2013
    ..The blood flow velocities in the temporal conjunctival microvasculature were 0.86±0.08 (mean±SD, mm/s) for the bare eye and 0.99±0.11 mm/s with contact lens wear. It is feasible to use RFI for imaging the conjunctival vasculature...
  18. ncbi request reprint Fully automated biometry of in situ intraocular lenses using long scan depth spectral-domain optical coherence tomography
    Qi Chen
    School of Ophthalmology and Optometry Q C, L L, D Z, Y W, Y S, F L, M S, Wenzhou Medical University, Wenzhou, Zhejiang, China and Department of Ophthalmology J W, Bascom Palmer Eye Institute, University of Miami, Miami, FL
    Eye Contact Lens 40:37-45. 2014
    ..The repeatability and reliability of the automated measurements were also evaluated...
  19. pmc Entire thickness profiles of the epithelium and contact lens in vivo imaged with high-speed and high-resolution optical coherence tomography
    Aizhu Tao
    Bascom Palmer Eye Institute, University of Miami, Miami, FL, USA
    Eye Contact Lens 39:329-34. 2013
    ..To test the feasibility of measuring the entire thickness profiles of the epithelium and contact lens (CL) in vivo, using high-speed and high-resolution spectral-domain optical coherence tomography (SD-OCT)...
  20. pmc Reduced tear meniscus dynamics in dry eye patients with aqueous tear deficiency
    Yimin Yuan
    Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida 33136, USA
    Am J Ophthalmol 149:932-938.e1. 2010
    ..To measure the tear meniscus dynamics in aqueous tear deficiency dry eye patients using optical coherence tomography...
  21. doi request reprint Corneal biomechanical properties and intraocular pressure in high myopic anisometropia
    Suzhong Xu
    School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical College, Wenzhou, Zhejiang, China
    Eye Contact Lens 36:204-9. 2010
    ..To investigate corneal biomechanical properties and intraocular pressure (IOP) in patients with high myopic anisometropia...
  22. doi request reprint Upper and lower tear menisci in the diagnosis of dry eye
    Meixiao Shen
    School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China
    Invest Ophthalmol Vis Sci 50:2722-6. 2009
    ..To measure the upper and lower tear menisci in patients with aqueous tear deficiency (ATD) dry eye by real-time optical coherence tomography (OCT) and to determine the most effective meniscus variables for the diagnosis of dry eye...
  23. pmc Anterior segment biometry during accommodation imaged with ultralong scan depth optical coherence tomography
    Chixin Du
    Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang, China
    Ophthalmology 119:2479-85. 2012
    ..To measure by ultralong scan depth optical coherence tomography (UL-OCT) dimensional changes in the anterior segment of human eyes during accommodation...
  24. pmc Automated segmentation and fractal analysis of high-resolution non-invasive capillary perfusion maps of the human retina
    Hong Jiang
    Bascom Palmer Eye Institute, University of Miami, Miami, FL, USA Departemnt of Neurology, University of Miami, Miami, 33136, USA
    Microvasc Res 89:172-5. 2013
    ..Both monofractal and multifractal analyses yielded similar results. The quantitative analyses of microvasculature at the capillary level may open up a new era for studying microvascular diseases such as cerebral small vessel disease. ..
  25. pmc Ultrahigh-resolution measurement by optical coherence tomography of dynamic tear film changes on contact lenses
    Qi Chen
    School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China
    Invest Ophthalmol Vis Sci 51:1988-93. 2010
    ..Conclusions. Ultrahigh-resolution OCT is a promising tool for measuring the tear film. The PoLTF did not increase after instillation of artificial tears...
  26. doi request reprint Age-related changes in tear menisci imaged by optical coherence tomography
    Lele Cui
    School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China
    Optom Vis Sci 88:1214-9. 2011
    ..To determine age-related changes of tear menisci in healthy subjects and to compare tear variables between age-matched normals and dry eye subjects...
  27. doi request reprint Vertical and horizontal thickness profiles of the corneal epithelium and Bowman's layer after orthokeratology
    Yan Lian
    School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China
    Invest Ophthalmol Vis Sci 54:691-6. 2013
    ..To investigate thickness profile changes of the corneal epithelium and Bowman's layer at the vertical and horizontal meridians with overnight myopia orthokeratology (OK) lenses...
  28. doi request reprint Changes in ocular response analyzer parameters after LASIK
    Shihao Chen
    Wenzhou Medical College, Wenzhou, Zhejiang, China
    J Refract Surg 26:279-88. 2010
    ..To investigate changes in Ocular Response Analyzer parameters after myopic LASIK...
  29. pmc Topographic thickness of Bowman's layer determined by ultra-high resolution spectral domain-optical coherence tomography
    Aizhu Tao
    School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China
    Invest Ophthalmol Vis Sci 52:3901-7. 2011
    ..To characterize the thickness profile of the corneal epithelium and the Bowman's layer across the horizontal meridian...
  30. pmc Extended scan depth optical coherence tomography for evaluating ocular surface shape
    Meixiao Shen
    Department of Ophthalmology, University of Miami, Bascom Palmer Eye Institute, 1638 NW 10th Avenue, Miami, Florida 33136, USA
    J Biomed Opt 16:056007. 2011
    ..The standard deviations of the height measurement within a 14-mm wide range were all less than 35 μm. This work demonstrates the feasibility of using extended depth SD-OCT to perform noninvasive evaluation of the ocular surface shape...
  31. doi request reprint Tear menisci after overnight contact lens wear
    Aizhu Tao
    School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China
    Optom Vis Sci 88:1433-8. 2011
    ..To determine the effect of overnight wear of contact lenses (CL) on tear meniscus, tear film stability, and subjective comfort...
  32. doi request reprint Clinical significance of tear menisci in dry eye
    Jianhua Li
    School of Ophthalmology and Optometry, Wenzhou Medical College, Zhejiang, China
    Eye Contact Lens 38:183-7. 2012
    ..To determine the relationships among tear menisci variables and clinical tests used in the diagnosis of dry eye patients...
  33. ncbi request reprint Lower volumes of tear menisci in contact lens wearers with dry eye symptoms
    Qi Chen
    School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China
    Invest Ophthalmol Vis Sci 50:3159-63. 2009
    ..To investigate tear meniscus volumes during short-term lens wear by soft contact lens (SCL) wearers with dryness symptoms...
  34. doi request reprint High resolution OCT quantitative analysis of the space between the IOL and the posterior capsule during the early cataract postoperative period
    Aizhu Tao
    School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
    Invest Ophthalmol Vis Sci 54:6991-7. 2013
    ..We quantitatively characterized the space between the IOL and the posterior capsule (IOL-PC space) during the early postphacoemulsification period, using high resolution optical coherence tomography (OCT)...
  35. pmc Visualization of the precorneal tear film using ultrahigh resolution optical coherence tomography in dry eye
    Lele Cui
    Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, FL 33136, USA
    Eye Contact Lens 38:240-4. 2012
    ..To visualize the precorneal tear film (PCTF) in dry eye patients using ultrahigh resolution optical coherence tomography (UHR-OCT)...
  36. doi request reprint Ultra-high resolution optical coherence tomography for differentiation of ocular surface squamous neoplasia and pterygia
    Jeremy Z Kieval
    Bascom Palmer Eye Institute, University of Miami, Miami, FL 33136, USA
    Ophthalmology 119:481-6. 2012
    ..To assess the use of an ultra-high-resolution (UHR) optical coherence tomography (OCT) as an adjuvant diagnostic tool in distinguishing ocular surface squamous neoplasia (OSSN) and pterygia...
  37. pmc The use of Bowman's layer vertical topographic thickness map in the diagnosis of keratoconus
    Mohamed Abou Shousha
    Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, Florida Saint Louis University Eye Institute, Saint Louis University, St Louis, Missouri Department of Ophthalmology, Faculty of Medicine, University of Alexandria, Alexandria, Egypt
    Ophthalmology 121:988-93. 2014
    ..To evaluate the use of Bowman's layer (BL) vertical topographic thickness maps in diagnosing keratoconus (KC)...
  38. ncbi request reprint Corneal reshaping and wavefront aberrations during overnight orthokeratology
    Yan Lian
    School of Ophthalmology and Optometry Y L, M S, S H, Y Y, Y W, D Z, J J, X M, and F L, Wenzhou Medical University, Wenzhou, Zhejiang, China and Department of Ophthalmology J W, Bascom Palmer Eye Institute, University of Miami, Miami, FL
    Eye Contact Lens 40:161-8. 2014
    ..To investigate changes of corneal thickness at the vertical and horizontal meridians and of wavefront aberrations (WA) over a 30-day period of overnight myopia orthokeratology (OK) lens wear...
  39. pmc Broadband superluminescent diode-based ultrahigh resolution optical coherence tomography for ophthalmic imaging
    Dexi Zhu
    Wenzhou Medical College, School of Ophthalmology and Optometry, Wenzhou, Zhejiang 325000, China
    J Biomed Opt 16:126006. 2011
    ..Our research demonstrated that ultrahigh -resolution SD-OCT can be achieved using broadband SLD in a simple way...
  40. doi request reprint The role of axial resolution of optical coherence tomography on the measurement of corneal and epithelial thicknesses
    Lili Ge
    School of Ophthalmology and Optometry, Wenzhou Medical College, Zhejiang, China
    Invest Ophthalmol Vis Sci 54:746-55. 2013
    ....
  41. doi request reprint Upper and lower tear menisci after laser in situ keratomileusis
    Aizhu Tao
    School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China
    Eye Contact Lens 36:81-5. 2010
    ..To determine upper and lower tear menisci using optical coherence tomography (OCT) in volunteers after laser in situ keratomileusis (LASIK) for myopia...
  42. ncbi request reprint Diurnal variation of upper and lower tear menisci
    Meixiao Shen
    School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China
    Am J Ophthalmol 145:801-6. 2008
    ..To determine diurnal variation of tear menisci around upper and lower eyelids in normal subjects...
  43. doi request reprint Biomechanical properties of the cornea in high myopia
    Meixiao Shen
    School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical College, 270 Xueyuan Road, Wenzhou, Zhejiang, China
    Vision Res 48:2167-71. 2008
    ..To determine corneal biomechanical properties in patients with high myopia...
  44. doi request reprint Tear meniscus volume in dry eye after punctal occlusion
    Feng Chen
    School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China
    Invest Ophthalmol Vis Sci 51:1965-9. 2010
    ..The absence of change in the tear menisci of control eyes may indicate the presence of an autoregulatory mechanism in the tear system that maintains a balance in the tear volume...
  45. doi request reprint Tear menisci and ocular discomfort during daily contact lens wear in symptomatic wearers
    Qi Chen
    School of Ophthalmology and Optometry, Wenzhou Medical College, 270 Xueyuan Road, Wenzhou, Zhejiang, China
    Invest Ophthalmol Vis Sci 52:2175-80. 2011
    ..To investigate the relationship between tear meniscus volumes and ocular discomfort during daily soft contact lens wear in symptomatic and asymptomatic wearers...
  46. pmc Diagnosis of ocular surface lesions using ultra-high-resolution optical coherence tomography
    Mohamed Abou Shousha
    Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, Florida 33136, USA
    Ophthalmology 120:883-91. 2013
    ..To assess the use of ultra-high-resolution (UHR) optical coherence tomography (OCT) in the diagnosis of ocular surface lesions...
  47. pmc Effect of blinking on tear volume after instillation of midviscosity artificial tears
    Jayachandra R Palakuru
    Bascom Palmer Eye Institute, University of Miami, Miami, Florida 33136, USA
    Am J Ophthalmol 146:920-4. 2008
    ..To determine by optical coherence tomography (OCT) the effect of blinking on ocular surface tear volume after instillation of artificial tears...
  48. doi request reprint Recovery of corneal hysteresis after reduction of intraocular pressure in chronic primary angle-closure glaucoma
    Lei Sun
    School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical College, Wenzhou, Zhejiang, China
    Am J Ophthalmol 147:1061-6, 1066.e1-2. 2009
    ..To measure corneal hysteresis (CH) in unilateral chronic primary angle-closure glaucoma (CPACG) patients to determine if it was affected by high intraocular pressure (IOP)...
  49. pmc Functional slit lamp biomicroscopy for imaging bulbar conjunctival microvasculature in contact lens wearers
    Hong Jiang
    Bascom Palmer Eye Institute, University of Miami, Miami, FL, USA Department of Neurology, University of Miami, Miami, FL, USA Electronic address
    Microvasc Res 92:62-71. 2014
    ..To develop, test and validate functional slit lamp biomicroscopy (FSLB) for generating non-invasive bulbar conjunctival microvascular perfusion maps (nMPMs) and assessing morphometry and hemodynamics...
  50. doi request reprint Automatic segmentation of the central epithelium imaged with three optical coherence tomography devices
    Lili Ge
    School of Ophthalmology and Optometry, Wenzhou Medical College, Zhejiang, China
    Eye Contact Lens 38:150-7. 2012
    ....
  51. doi request reprint Biometric measurement of the mouse eye using optical coherence tomography with focal plane advancement
    Xiangtian Zhou
    School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical College, Wenzhou, Zhejiang, 325003, China
    Vision Res 48:1137-43. 2008
    ..To demonstrate that high-resolution biometry is possible in mouse eyes in vivo, using real-time OCT with focal plane advancement by a stepper motor...
  52. pmc Entire contact lens imaged in vivo and in vitro with spectral domain optical coherence tomography
    Meixiao Shen
    Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miami, Florida 33136, USA
    Eye Contact Lens 36:73-6. 2010
    ..To demonstrate the capability of directly visualizing the entire ocular surface and the entire contact lens on the eye using spectral domain optical coherence tomography (SD-OCT)...
  53. ncbi request reprint Correlation between corneal biomechanical properties, applanation tonometry and direct intracameral tonometry
    A Yong Yu
    School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China
    Br J Ophthalmol 96:640-4. 2012
    ..To investigate the correlation between corneal biomechanical properties, applanation tonometry and direct intracameral tonometry...
  54. pmc Use of ultra-high-resolution optical coherence tomography to detect in vivo characteristics of Descemet's membrane in Fuchs' dystrophy
    Mohamed Abou Shousha
    Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, FL 33136, USA
    Ophthalmology 117:1220-7. 2010
    ..2) To evaluate the use of DM characteristics and thickness in the diagnosis of Fuchs' dystrophy...
  55. pmc Genetic deletion of the adenosine A2A receptor confers postnatal development of relative myopia in mice
    Xiangtian Zhou
    School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical College, Wenzhou, China
    Invest Ophthalmol Vis Sci 51:4362-70. 2010
    ..To critically evaluate whether the adenosine A2A receptor (A2AR) plays a role in postnatal refractive development in mice...
  56. doi request reprint Complications of femtosecond laser-assisted re-treatment for residual refractive errors after LASIK
    Pravin K Vaddavalli
    Miller School of Medicine, University of Miami, Miami, FL, USA
    J Refract Surg 29:577-80. 2013
    ..To report complications of femtosecond laser-assisted re-treatment by the creation of side cuts within the old flaps for residual refractive error after primary LASIK in two patients...
  57. pmc Daytime variations of tear osmolarity and tear meniscus volume
    Ming Li
    Bascom Palmer Eye Institute, University of Miami, Miami, FL 33136, USA
    Eye Contact Lens 38:282-7. 2012
    ..The aim of this study was to determine the pattern of variations in tear osmolarity and tear meniscus volume in patients with dry eyes and in healthy control subjects over an 8-hr daytime period...
  58. doi request reprint SD-OCT with prolonged scan depth for imaging the anterior segment of the eye
    Meixiao Shen
    Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, 1638 NW 10th Avenue, Miami, FL 33136, USA
    Ophthalmic Surg Lasers Imaging 41:S65-9. 2010
    ..The system was also tested in imaging accommodation of the same eye, demonstrating the feasibility of the novel approach for evaluating presbyopia/accommodation...
  59. pmc Characterization of soft contact lens edge fitting using ultra-high resolution and ultra-long scan depth optical coherence tomography
    Meixiao Shen
    Departments of Ophthalmology, Bascom Palmer Eye Institute, Jacksonville, Florida, USA
    Invest Ophthalmol Vis Sci 52:4091-7. 2011
    ..To characterize the edge fitting of soft contact lenses using ultra-high resolution optical coherence tomography (UHR-OCT) and ultra-long scan depth optical coherence tomography (UL-OCT)...
  60. doi request reprint Diagnosis and management of conjunctival and corneal intraepithelial neoplasia using ultra high-resolution optical coherence tomography
    Mohamed Abou Shousha
    Bascom Palmer Eye Institute, Miller School of Medicine, University of Miami, Miami, Florida, USA
    Ophthalmology 118:1531-7. 2011
    ..To report a novel diagnostic technique and a case series of conjunctival and corneal intraepithelial neoplasia (CCIN) diagnosed and followed up using prototype ultra high-resolution (UHR) optical coherence tomography (OCT)...
  61. doi request reprint Ultra high-resolution anterior segment optical coherence tomography in the evaluation of anterior corneal dystrophies and degenerations
    Lejla M Vajzovic
    Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
    Ophthalmology 118:1291-6. 2011
    ..To evaluate the clinical usefulness of a spectral-domain ultra high-resolution anterior segment optical coherence tomography (UHR OCT) in examination, diagnosis, and management of various anterior corneal dystrophies and degenerations...
  62. pmc Phacoemulsification induced transient swelling of corneal Descemet's Endothelium Complex imaged with ultra-high resolution optical coherence tomography
    Aizhu Tao
    School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China
    PLoS ONE 8:e80986. 2013
    ..Thickness changes of corneal sub-layers after phacoemulsification were investigated by spectral domain ultra-high resolution optical coherence tomography (UHR-OCT)...
  63. pmc Photorefractive keratectomy in the cat eye: biological and optical outcomes
    Lana J Nagy
    Department of Ophthalmology, University of Rochester, 601 Elmwood Avenue, Rochester, NY 14642, USA
    J Cataract Refract Surg 33:1051-64. 2007
    ..To quantify optical and biomechanical properties of the feline cornea before and after photorefractive keratectomy (PRK) and assess the relative contribution of different biological factors to refractive outcome...
  64. ncbi request reprint Upper and lower tear menisci on contact lenses
    Jianhua Wang
    Bascom Palmer Eye Institute, University of Miami, Miami, Florida 33136, USA
    Invest Ophthalmol Vis Sci 50:1106-11. 2009
    ..The purpose of this study was to measure upper and lower tear menisci on contact lenses using real time optical coherence tomography (OCT)...
  65. doi request reprint Resolution of slit-lamp microscopy photography using various cameras
    Yufeng Ye
    Department of Ophthalmology, Hangzhou First People s Hospital, Hangzhou, China
    Eye Contact Lens 39:205-13. 2013
    ..To evaluate the resolutions of slit-lamp microscopy photography using various cameras...
  66. pmc Micrometer-scale contact lens movements imaged by ultrahigh-resolution optical coherence tomography
    Lele Cui
    Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miami, FL 33136, USA
    Am J Ophthalmol 153:275-283.e1. 2012
    ..To dynamically evaluate contact lens movement and ocular surface shape using ultrahigh-resolution and ultralong-scan-depth optical coherence tomography (OCT)...
  67. ncbi request reprint Effect of blinking on tear dynamics
    Jayachandra R Palakuru
    Department of Ophthalmology, University of Rochester, Rochester, New York, USA
    Invest Ophthalmol Vis Sci 48:3032-7. 2007
    ..Optical coherence tomography (OCT) was used to study the impact of blinking on tear dynamics...
  68. pmc Retinal oximetry using ultrahigh-resolution optical coherence tomography
    Yufeng Ye
    Hangzhou First People s Hospital, Hangzhou, China Bascom Palmer Eye Institute, University of Miami, Miami, FL, USA
    Clin Ophthalmol 6:2085-92. 2012
    ..The purpose of this study was to investigate the repeatability of retinal oximetry using slit-lamp adapted ultrahigh-resolution optical coherence tomography (SL-UHR-OCT)...
  69. pmc Repeated measurements of dynamic tear distribution on the ocular surface after instillation of artificial tears
    Jianhua Wang
    Department of Ophthalmology, University of Rochester, NY 14642, USA
    Invest Ophthalmol Vis Sci 47:3325-9. 2006
    ..To determine the repeatability of real-time optical coherence tomography (OCT) measurements of tear film thickness (TFT) and variables of tear film menisci...
  70. doi request reprint Corneal haze following disruption of epithelial basement membrane on ultra-high-resolution OCT following femtosecond LASIK
    Pravin K Vaddavalli
    Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, FL 33136, USA
    J Refract Surg 28:72-4. 2012
    ..To analyze in vivo structural properties of a case with interface haze that developed after femtosecond laser-assisted LASIK...
  71. doi request reprint Atypical presentation of Salzmann nodular degeneration diagnosed with ultra-high-resolution optical coherence tomography
    Volkan Hurmeric
    Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, Miami, Florida 33136, USA
    Ophthalmic Surg Lasers Imaging 42:e122-5. 2011
    ..UHR-OCT findings were consistent with Salzmann nodular degeneration. UHR-OCT can be used as an optical biopsy to diagnose atypical corneal degenerations without tissue sampling...
  72. doi request reprint Persistent lamellar interface fluid with clear cornea after Descemet stripping automated endothelial keratoplasty
    Volkan Hurmeric
    Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL 33136, USA
    Cornea 30:1485-7. 2011
    ..To describe clinical properties of a patient with persistent interface fluid syndrome and clear graft, 3.5 years after Descemet stripping automated endothelial keratoplasty (DSAEK)...
  73. pmc Axial biometry of the entire eye using ultra-long scan depth optical coherence tomography
    Jianguang Zhong
    Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida Department of Ophthalmology, Hangzhou First People s Hospital, Hangzhou, Zhejiang, China
    Am J Ophthalmol 157:412-420.e2. 2014
    ..To assess the repeatability of axial biometry of the entire eye using ultra-long scan depth optical coherence tomography (OCT) and to investigate the agreement with IOLMaster measurements (Carl Zeiss Meditec)...
  74. pmc Vertical and horizontal corneal epithelial thickness profiles determined by ultrahigh resolution optical coherence tomography
    Chixin Du
    Department of Ophthalmology, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang, China
    Cornea 31:1036-43. 2012
    ..To measure vertical and horizontal thickness profiles of the central and peripheral corneal epithelium and determine if daytime changes occur...
  75. ncbi request reprint Slit-lamp-adapted ultra-high resolution OCT for imaging the posterior segment of the eye
    Hong Jiang
    Division of Neuro ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miami, Florida 33136, USA
    Ophthalmic Surg Lasers Imaging 43:76-81. 2012
    ..The authors described the system configuration, build-up, and test results of a small sample of human subjects. The comparison with a commercially available device was also included...
  76. pmc Repeated measurements of the anterior segment during accommodation using long scan depth optical coherence tomography
    Yimin Yuan
    School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, China
    Eye Contact Lens 38:102-8. 2012
    ..The aim was to determine the repeatability of ultralong scan depth spectral-domain optical coherence tomography (SD-OCT) measurements of the ocular anterior segment during accommodation...
  77. doi request reprint In vivo structural characteristics of the femtosecond LASIK-induced opaque bubble layers with ultrahigh-resolution SD-OCT
    Volkan Hurmeric
    Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, 900 NW 17 Street, Miami, FL, USA
    Ophthalmic Surg Lasers Imaging 41:S109-13. 2010
    ..UHR-OCT imaging can be used to demonstrate the structural characteristics of OBL. It has the potential to be used to predict incomplete lamellar flap dissections in patients with opaque bubble layers...
  78. pmc In vivo morphologic characteristics of Salzmann nodular degeneration with ultra-high-resolution optical coherence tomography
    Volkan Hurmeric
    Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida 33136, USA
    Am J Ophthalmol 151:248-56.e2. 2011
    ..To examine the in vivo morphologic properties of Salzmann nodular degeneration with ultra-high-resolution optical coherence tomography (OCT)...
  79. doi request reprint Intraoperative use of three-dimensional spectral-domain optical coherence tomography
    Takeshi Ide
    Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA
    Ophthalmic Surg Lasers Imaging 41:250-4. 2010
    ..To develop a prototype three-dimensional anterior segment spectral-domain optical coherence tomography (SD-OCT) device and demonstrate the feasibility of its use in the operating room...
  80. doi request reprint Epithelial ingrowth after Descemet stripping automated endothelial keratoplasty: description of cases and assessment with anterior segment optical coherence tomography
    Leejee H Suh
    Bascom Palmer Eye Institute, Miami, FL 33136, USA
    Cornea 30:528-34. 2011
    ..To describe 5 cases of epithelial ingrowth after Descemet stripping automated endothelial keratoplasty (DSAEK) and the use of anterior segment optical coherence tomography (AS-OCT) to describe the areas of ingrowth...
  81. pmc Ultra high-resolution anterior segment optical coherence tomography in the diagnosis and management of ocular surface squamous neoplasia
    Benjamin J Thomas
    Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA
    Ocul Surf 12:46-58. 2014
    ....
  82. pmc Cochlin, intraocular pressure regulation and mechanosensing
    Manik Goel
    Bascom Palmer Eye Institute, University of Miami, Miami, Florida, United States of America
    PLoS ONE 7:e34309. 2012
    ..Taken together with previous studies, we show cochlin is involved in regulation of intraocular pressure in DBA/2J potentially through mechanosensing of the shear stress...
  83. pmc Three-dimensional spectral domain optical coherence tomography of a clear corneal cataract incision
    Theodore Leng
    Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA
    Ophthalmic Surg Lasers Imaging 39:S132-4. 2008
    ..SD-OCT can be used to analyze clear corneal incisions to determine optimal wound construction technique and geometry as they relate to the prevention of complications such as postoperative wound leak, infection, and epithelial ingrowth...
  84. ncbi request reprint Comparison of corneal thickness measured with optical coherence tomography, ultrasonic pachymetry, and a scanning slit method
    Joseph Thomas
    Department of Ophthalmology, Case Western Reserve University University Hospitals of Cleveland, Cleveland, Ohio, USA
    J Refract Surg 22:671-8. 2006
    ..To investigate the relationship between 1310-nm optical coherence tomography (OCT), an ultrasound pachymeter, and the Orbscan II (Bausch & Lomb, Rochester, NY) in corneal thickness measurements before and after LASIK...
  85. pmc Evaluation of a transgenic mouse model of multiple sclerosis with noninvasive methods
    Mabel Enriquez-Algeciras
    Bascom Palmer Eye Institute, University of Miami, Miami, Florida 33136, USA
    Invest Ophthalmol Vis Sci 52:2405-11. 2011
    ..To evaluate the ND4 transgenic mouse model of multiple sclerosis using noninvasive methods...
  86. pmc Improving image segmentation performance and quantitative analysis via a computer-aided grading methodology for optical coherence tomography retinal image analysis
    Delia Cabrera DeBuc
    University of Miami, Miller School of Medicine, Bascom Palmer Eye Institute, Miami, Florida 33136, USA
    J Biomed Opt 15:046015. 2010
    ..Our methodology facilitates a more robust and localized quantification of the retinal structure in normal healthy controls and patients with clinically significant intraretinal features...
  87. ncbi request reprint Noncontact measurements of central corneal epithelial and flap thickness after laser in situ keratomileusis
    Jianhua Wang
    School of Optometry, University of Waterloo, Waterloo, Ontario, Canada
    Invest Ophthalmol Vis Sci 45:1812-6. 2004
    ..To investigate the changes in the epithelium and flap after laser in situ keratomileusis (LASIK), when measured with optical coherence tomography (OCT)...
  88. ncbi request reprint Relation between optical coherence tomography and optical pachymetry measurements of corneal swelling induced by hypoxia
    Jianhua Wang
    Centre for Contact Lens Research, School of Optometry, University of Waterloo, Ontario, Canada
    Am J Ophthalmol 134:93-8. 2002
    ..To determine the relation between optical coherence tomography (OCT) and optical pachymetry (OP) measurements of corneal swelling induced by hypoxia...
  89. ncbi request reprint Objective measurements of corneal light-backscatter during corneal swelling, by optical coherence tomography
    Jianhua Wang
    Centre for Contact Lens Research, School of Optometry, University of Waterloo, Waterloo, Ontario, Canada
    Invest Ophthalmol Vis Sci 45:3493-8. 2004
    ..To demonstrate that corneal light-backscatter can be measured objectively during corneal swelling by optical coherence tomography (OCT)...
  90. ncbi request reprint Central corneal thickness and corneal hysteresis during corneal swelling induced by contact lens wear with eye closure
    Fan Lu
    School of Ophthalmology and Optometry, Wenzhou Medical College, Wenzhou, Zhejiang, China
    Am J Ophthalmol 143:616-22. 2007
    ..To determine if corneal hysteresis (CH) was associated with increased central corneal thickness (CCT) induced by wearing soft contact lenses during eye closure...
  91. ncbi request reprint Isolation and analysis of water stress induced genes in maize seedlings by subtractive PCR and cDNA macroarray
    Jun Zheng
    State Key Laboratory of Agrobiotechnology, National Plant Gene Research Center Beijing, China Agricultural University, Beijing 100094, China
    Plant Mol Biol 55:807-23. 2004
    ..A set of transcripts has been identified, which have significantly increased expression and probably involved in water stress signaling pathway based on data analysis...
  92. ncbi request reprint Corneal light backscatter measured by optical coherence tomography after LASIK
    Jianhua Wang
    Dept of Ophthalmology, Box 314, University of Rochester Medical Center, Rochester, NY 14642, USA
    J Refract Surg 22:604-10. 2006
    ..To objectively quantify corneal light backscatter after LASIK using optical coherence tomography (OCT)...

Research Grants1

  1. Characterization of Tear Dynamics
    Jianhua Wang; Fiscal Year: 2007
    ..g. dry eye). ..