Chenyang Wang

Summary

Affiliation: University of Pennsylvania
Country: USA

Publications

  1. doi request reprint Automatic step-detection algorithm for analysis of sarcomere dynamics
    Chenyang Wang
    Department of Bioengineering, University of Washington, Seattle, WA, USA
    Comput Methods Biomech Biomed Engin 11:609-14. 2008
  2. pmc Validation of sodium magnetic resonance imaging of intervertebral disc
    Chenyang Wang
    CMROI, Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA
    Spine (Phila Pa 1976) 35:505-10. 2010
  3. doi request reprint Magnetization transfer ratio mapping of intervertebral disc degeneration
    Chenyang Wang
    Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104 6100, USA
    Magn Reson Med 64:1520-8. 2010
  4. pmc Measurement of intervertebral disc pressure with T 1ρ MRI
    Chenyang Wang
    Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104 6100, USA
    Magn Reson Med 64:1721-7. 2010
  5. pmc Artifacts in T1 rho-weighted imaging: compensation for B(1) and B(0) field imperfections
    Walter R T Witschey
    Graduate Group in Biochemistry and Molecular Biophysics and MMRRCC, University of Pennsylvania, B1 Stellar Chance Laboratories, 422 Curie Boulevard, Philadelphia, PA 19104 6100, USA
    J Magn Reson 186:75-85. 2007
  6. pmc T1rho-prepared balanced gradient echo for rapid 3D T1rho MRI
    Walter R T Witschey
    Metabolic Magnetic Resonance Research and Computing Center, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 6100, USA
    J Magn Reson Imaging 28:744-54. 2008
  7. doi request reprint T1ρ magnetic resonance imaging and discography pressure as novel biomarkers for disc degeneration and low back pain
    Arijitt Borthakur
    Center for Magnetic Resonance and Optical Imaging, Department of Radiology, University of Pennsylvania, Philadelphia 19104, USA
    Spine (Phila Pa 1976) 36:2190-6. 2011
  8. pmc Compensation for spin-lock artifacts using an off-resonance rotary echo in T1rhooff-weighted imaging
    Walter R T Witschey
    Department of Biochemistry and Molecular Biophysics, University of Pennsylvania, Philadelphia, Pennsylvania 19104 6100, USA
    Magn Reson Med 57:2-7. 2007

Detail Information

Publications8

  1. doi request reprint Automatic step-detection algorithm for analysis of sarcomere dynamics
    Chenyang Wang
    Department of Bioengineering, University of Washington, Seattle, WA, USA
    Comput Methods Biomech Biomed Engin 11:609-14. 2008
    ..The algorithm presented here offers a versatile and accurate tool that should be useful not only within muscle contraction and motility fields, but in fields which quantal phenomena play a role...
  2. pmc Validation of sodium magnetic resonance imaging of intervertebral disc
    Chenyang Wang
    CMROI, Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA
    Spine (Phila Pa 1976) 35:505-10. 2010
    ..This study demonstrated the diagnostic potential of sodium (Na) magnetic resonance imaging (MRI) for noninvasive quantification of proteoglycan (PG) in the intervertebral discs...
  3. doi request reprint Magnetization transfer ratio mapping of intervertebral disc degeneration
    Chenyang Wang
    Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104 6100, USA
    Magn Reson Med 64:1520-8. 2010
    ..In summary, magnetization transfer MRI of the disc may serve as a noninvasive diagnostic tool for disc degeneration, in addition to other MRI techniques specific to proteoglycan content...
  4. pmc Measurement of intervertebral disc pressure with T 1ρ MRI
    Chenyang Wang
    Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104 6100, USA
    Magn Reson Med 64:1721-7. 2010
    ..Therefore, T(1ρ) MRI may serve as a noninvasive clinical tool for the longitudinal evaluation of disc osmotic pressure...
  5. pmc Artifacts in T1 rho-weighted imaging: compensation for B(1) and B(0) field imperfections
    Walter R T Witschey
    Graduate Group in Biochemistry and Molecular Biophysics and MMRRCC, University of Pennsylvania, B1 Stellar Chance Laboratories, 422 Curie Boulevard, Philadelphia, PA 19104 6100, USA
    J Magn Reson 186:75-85. 2007
    ..The new pulse sequence can be used to probe very low frequency (0-400 Hz) dynamic and static interactions in tissues without contaminating B(0) and B(1) field artifacts...
  6. pmc T1rho-prepared balanced gradient echo for rapid 3D T1rho MRI
    Walter R T Witschey
    Metabolic Magnetic Resonance Research and Computing Center, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 6100, USA
    J Magn Reson Imaging 28:744-54. 2008
    ....
  7. doi request reprint T1ρ magnetic resonance imaging and discography pressure as novel biomarkers for disc degeneration and low back pain
    Arijitt Borthakur
    Center for Magnetic Resonance and Optical Imaging, Department of Radiology, University of Pennsylvania, Philadelphia 19104, USA
    Spine (Phila Pa 1976) 36:2190-6. 2011
    ..Prospective magnetic resonance imaging (MRI) study of patients low back pain (LBP) requiring discography as part of their routine clinical diagnoses and asymptomatic age-matched volunteers...
  8. pmc Compensation for spin-lock artifacts using an off-resonance rotary echo in T1rhooff-weighted imaging
    Walter R T Witschey
    Department of Biochemistry and Molecular Biophysics, University of Pennsylvania, Philadelphia, Pennsylvania 19104 6100, USA
    Magn Reson Med 57:2-7. 2007
    ..The underlying theory is detailed, and MR images demonstrate the effectiveness of the technique in agarose gel phantoms and in in vivo human brain at 3T...