Research Topics
| Wim VerkruysseSummaryAffiliation: University of California Country: USA Publications
|
Detail Information
Publications
Spectral variation of the infrared absorption coefficient in pulsed photothermal profiling of biological samplesBoris Majaron
Jozef Stefan Institute, Jamova, Ljubljana, Slovenia
Phys Med Biol 47:1929-46. 2002..Implementation of the latter approach for depth profiling of port wine stain birthmarks in vivo is presented and discussed...
Determination of an optimized conversion matrix for device independent skin color image analysisChang Seok Kim
Beckman Laser Institute and Medical Clinic, University of California, Irvine, CA 92612, USA
Lasers Surg Med 37:138-43. 2005..To obtain calibrated Commission International de l'Eclairage (CIE) color space images from RGB (red, green, and blue) images, it was necessary to derive an optimized conversion matrix specific to our imaging system...
Remote plethysmographic imaging using ambient lightWim Verkruysse
Beckman Laser Institue, University of California, Irvine, 1002 Health Sciences Rd East, Irvine, CA 92612, USA
Opt Express 16:21434-45. 2008..g., port wine stains) and remote sensing of vital signs (e.g., heart and respiration rates) for triage or sports purposes...
Thermal depth profiling of vascular lesions: automated regularization of reconstruction algorithmsWim Verkruysse
Beckman Laser Institute and Medical Clinic, University of California, Irvine, CA 92612, USA
Phys Med Biol 53:1463-74. 2008..Similar, or better, accuracy reconstructions can be achieved with an automated regularization procedure which enhances prospects for user friendly implementation of PPTR to optimize laser therapy on an individual patient basis...
Infrared measurement of human skin temperature to predict the individual maximum safe radiant exposure (IMSRE)Wim Verkruysse
Beckman Laser Institute and Medical Clinic, University of California Irvine, 1002 Health Sciences Road East, Irvine, CA 92612, USA
Lasers Surg Med 39:757-66. 2007..An objective and quantitative method to assess the individual maximum safe radiant exposure (IMSRE) would help clinicians optimize LHR while at the same time providing the safest possible laser therapy...
Comparison of diffusion approximation and Monte Carlo based finite element models for simulating thermal responses to laser irradiation in discrete vesselsRong Zhang
Beckman Laser Institute, University of California, Irvine, CA 92612, USA
Phys Med Biol 50:4075-86. 2005..The disadvantage is that a multidimensional ISF table is needed for DA-FEM-ISF to be a practical modelling tool...
Determination of human skin optical properties from spectrophotometric measurements based on optimization by genetic algorithmsRong Zhang
University of California, Beckman Laser Institute, 1002 Health Sciences Road East, Irvine, California 92612, USA
J Biomed Opt 10:024030. 2005..Furthermore, the GA approach can lead to a reasonable understanding of the blood volume fraction and other skin properties, provided that the applicability of the diffusion approximation is satisfied...
A library based fitting method for visual reflectance spectroscopy of human skinWim Verkruysse
Beckman Laser Institute, University of California, Irvine, CA 92612, USA
Phys Med Biol 50:57-70. 2005..The method is demonstrated using both simulated and measured reflectance spectra. An additional advantage of the method is that the fitting procedure is very fast...
Improvement of port wine stain laser therapy by skin preheating prior to cryogen spray cooling: a numerical simulationWangcun Jia
Beckman Laser Institute, University of California, Irvine, 92612, USA 92612, USA
Lasers Surg Med 38:155-62. 2006....
Remittance at a single wavelength of 390 nm to quantify epidermal melanin concentrationWim Verkruysse
University of California, Irvine Beckman Laser Institute, 1002 Health Sciences Road, Irvine, California 92612, USA
J Biomed Opt 14:014005. 2009..Due to the shallow penetration depth and independence of blood oxygen saturation (isosbestic point), remittance at 390 nm appears to provide better estimates for EMC and IMSRE than MI...
Novel algorithm for tomographic reconstruction of atmospheric chemicals with sparse samplingWim Verkruysse
Beckman Laser Institute, University of California-Irvine, Irvine, California, USA
Environ Sci Technol 39:2247-54. 2005..Results using the GT-MG method were dramatically improved over previously used methods. Quantitatively, peak exposure errors were reduced by up to 85% and artifacts were dramatically minimized...
