Tae Moon Jeong

Summary

Affiliation: University of Rochester
Country: USA

Publications

  1. ncbi request reprint Measurement of wave-front aberration in soft contact lenses by use of a Shack-Hartmann wave-front sensor
    Tae Moon Jeong
    Center for Visual Science, University of Rochester, New York 14627, USA
    Appl Opt 44:4523-7. 2005
  2. ncbi request reprint Vision improvement by correcting higher-order aberrations with customized soft contact lenses in keratoconic eyes
    Ramkumar Sabesan
    Institute of Optics, University of Rochester, Rochester, New York 14627, USA
    Opt Lett 32:1000-2. 2007
  3. ncbi request reprint Characterizing the wave aberration in eyes with keratoconus or penetrating keratoplasty using a high-dynamic range wavefront sensor
    Seth Pantanelli
    Department of Biomedical Engineering, Center for Visual Science, University of Rochester, Rochester, New York 14627, USA
    Ophthalmology 114:2013-21. 2007
  4. ncbi request reprint Vision improvement by correcting higher-order aberrations with phase plates in normal eyes
    Geunyoung Yoon
    Department of Ophthalmology, Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
    J Refract Surg 20:S523-7. 2004

Detail Information

Publications4

  1. ncbi request reprint Measurement of wave-front aberration in soft contact lenses by use of a Shack-Hartmann wave-front sensor
    Tae Moon Jeong
    Center for Visual Science, University of Rochester, New York 14627, USA
    Appl Opt 44:4523-7. 2005
    ..A Shack-Hartmann wave-front sensor can be used to assess optical quality of both conventional and customized soft contact lenses and to assist in enhancing lens quality control...
  2. ncbi request reprint Vision improvement by correcting higher-order aberrations with customized soft contact lenses in keratoconic eyes
    Ramkumar Sabesan
    Institute of Optics, University of Rochester, Rochester, New York 14627, USA
    Opt Lett 32:1000-2. 2007
    ..The higher-order aberration correction resulted in an average improvement of 2.1 lines in visual acuity over the conventional correction of defocus and astigmatism alone...
  3. ncbi request reprint Characterizing the wave aberration in eyes with keratoconus or penetrating keratoplasty using a high-dynamic range wavefront sensor
    Seth Pantanelli
    Department of Biomedical Engineering, Center for Visual Science, University of Rochester, Rochester, New York 14627, USA
    Ophthalmology 114:2013-21. 2007
    ..The purpose of this study was to characterize aberrations in 2 populations of eyes, namely those with keratoconus (KC) and those having undergone penetrating keratoplasty (PK), using a large-dynamic range Shack-Hartmann wavefront sensor...
  4. ncbi request reprint Vision improvement by correcting higher-order aberrations with phase plates in normal eyes
    Geunyoung Yoon
    Department of Ophthalmology, Center for Visual Science, University of Rochester, Rochester, NY 14627, USA
    J Refract Surg 20:S523-7. 2004
    ..To psychophysically demonstrate vision improvement when correcting higher-order aberrations with phase plates in normal eyes...