Research Topics
| T A ChuterSummaryAffiliation: University of California Country: USA Publications
| Collaborators
|
Detail Information
Publications
Endovascular repair of a presumed aortoenteric fistula: late failure due to recurrent infectionT A Chuter
Department of Surgery, University of California, San Francisco 94143, USA
J Endovasc Ther 7:240-4. 2000..To describe a case of presumed aortoduodenal fistula that was treated by endovascular implantation of a stent-graft...
The choice of stent-graft for endovascular repair of abdominal aortic aneurysmT A M Chuter
Department of Surgery, University of California, San Francisco, CA 94143, USA
J Cardiovasc Surg (Torino) 44:519-25. 2003..Graft thrombosis is also unusual when the prostheses is fully-stented. In conclusion, modern devices are more versatile, more effective, and more durable than their first generation counterparts...
Development of a branched stent-graft for endovascular repair of aortic arch aneurysmsTimothy A M Chuter
Division of Vascular Surgery, University of California, San Francisco, California 94143, USA
J Endovasc Ther 10:940-5. 2003..To develop a branched stent-graft for endovascular repair of aortic arch aneurysm...
Endovascular treatment of thoracoabdominal aortic aneurysmsT A M Chuter
Division of Vascular Surgery, University of California, San Francisco, CA, USA
J Cardiovasc Surg (Torino) 47:619-28. 2006..In the past year, we have used this approach to implant multi-branched thoracoabdominal stent-graft in 16 patients. In our opinion, this approach will eventually assume a prominent role in the management of TAAA...
Heparin-induced thrombocytopenia and graft thrombosis following endovascular aneurysm repairTimothy A M Chuter
Division of Vascular Surgery, University of California, San Francisco, California 94143, USA
J Endovasc Ther 10:1087-90. 2003..To report a case of heparin-induced thrombocytopenia (HIT) complicated by stent-graft thrombosis...
Endovascular treatment of thoracoabdominal aortic aneurysmsTimothy A M Chuter
Division of Vascular Surgery, University of California San Francisco, 400 Parnassus Avenue, San Francisco, CA 94143, USA
J Vasc Surg 47:6-16. 2008..This study assessed the role of multibranched stent grafts for thoracoabdominal aortic aneurysm (TAAA) repair...
Branched stent-grafts: will these become the new standard?Timothy A M Chuter
Division of Vascular Surgery, University of California San Francisco, 400 Parnassus Avenue, San Francisco, CA 94143, USA
J Vasc Interv Radiol 19:S57-62. 2008..The authors generally favor the use of branched stent-grafts in the thoracoabdominal aorta and a combined approach in the aortic arch...
Suprarenal stents and other advances in endovascular aneurysm repairTimothy A M Chuter
Division of Vascular Surgery, UCSF, 505 Parnassus Ave, M 488, San Francisco, CA 94143, USA
Surg Clin North Am 84:1319-35, vii. 2004..It is important to make note of these technological features incorporated in current stent-grafts and the clinical experience that precipitated their introduction as the technology progresses and new applications are proposed...
Management of abdominal aortic aneurysm: a decade of progressTimothy A M Chuter
Division of Vascular Surgery, UCSF, San Francisco, California 94143, USA
J Endovasc Ther 11:II82-95. 2004....
Branched and fenestrated stent grafts for endovascular repair of thoracic aortic aneurysmsTimothy A M Chuter
UCSF Division of Vascular Surgery, San Francisco, Calif 94143, USA
J Vasc Surg 43:111A-115A. 2006
Modular branched stent graft for endovascular repair of aortic arch aneurysm and dissectionTimothy A M Chuter
Division of Vascular Surgery, University of California San Francisco, 505 Parnassus Avenue, M 488, San Francisco, CA 94143, USA
J Vasc Surg 38:859-63. 2003..We describe a modular stent graft for use in endovascular repair of aneurysms of the aortic arch...
Endovascular repair of the aortic archTimothy A M Chuter
Division of Vascular Surgery, University of California, San Francisco, CA 94143, USA
Perspect Vasc Surg Endovasc Ther 19:188-92. 2007..Despite high flows and wide-diameter components, current experience has shown bifurcated stent grafts of this type to be stable with follow-up over 3 years...
Durability of endovascular infrarenal aneurysm repair: when does late failure occur and why?Timothy A M Chuter
Division of Vascular Surgery, University of California San Francisco, San Francisco, CA 94143, USA
Semin Vasc Surg 22:102-10. 2009..New, or recently modified, devices cannot necessarily be assumed to be as durable as their predecessors...
An endovascular system for thoracoabdominal aortic aneurysm repairT A Chuter
Department of Surgery, University of California San Francisco, USA
J Endovasc Ther 8:25-33. 2001..To describe a stent-graft system for endovascular repair of thoracoabdominal aortic aneurysm (TAAA) that preserves side branch perfusion...
Stent-graft design: the good, the bad and the uglyTimothy A M Chuter
UCSF, Division of Vascular Surgery, 505, Parnassus Ave, M 488 San Francisco, CA 94143, USA
Cardiovasc Surg 10:7-13. 2002....
Fenestrated and branched stent-grafts for thoracoabdominal, pararenal and juxtarenal aortic aneurysm repairTimothy A M Chuter
Division of Vascular Surgery, University of California San Francisco, San Francisco, CA 94143, USA
Semin Vasc Surg 20:90-6. 2007..However, the enormous potential advantages of endovascular repair of visceral segment aneurysms and promising short-term results continue to drive the dissemination of branched stent-graft technology...
The transition from custom-made to standardized multibranched thoracoabdominal aortic stent graftsTimothy A M Chuter
Division of Vascular Surgery, University of California San Francisco, San Francisco, CA 94143, USA
J Vasc Surg 54:660-7; discussion 667-8. 2011..The purpose of this study was to compare the branch morphology and short-term outcome of endovascular aneurysm repair using multibranched thoracoabdominal custom-made stent grafts (CSGs) vs standard stent grafts (SSGs)...
Endovascular repair in the ascending aorta: stretching the limits of current technologyTimothy A M Chuter
Division of Vascular Surgery, UCSF Medical Center, San Francisco, California 94143-0628, USA
J Endovasc Ther 14:799-800. 2007
Aortic stent-grafts in patients with renal transplantsR Sawhney
Department of Radiology, University of California, San Francisco, USA
J Endovasc Ther 7:286-91. 2000..To report the endovascular treatment of abdominal aortic aneurysms (AAA) in 2 patients with pelvic renal transplants...
Analysis of initial CT findings after endovascular repair of abdominal aortic aneurysmR Sawhney
Department of Radiology, University of California, San Francisco, USA
Radiology 220:157-60. 2001..To determine the spectrum and frequency of specific computed tomographic (CT) findings in the acute period after endovascular repair of abdominal aortic aneurysm (AAA)...
Hemodynamic determinants of aortic dissection propagation by 2D computational modeling: implications for endovascular stent-graftingS Chitsaz
Division of Cardiothoracic Surgery, Department of Surgery, University of California at San Francisco Medical Center and San Francisco VA Medical Center, San Francisco, CA 94143, USA
J Cardiovasc Surg (Torino) 53:631-40. 2012..The purpose of this study was to perform computational fluid dynamics (CFD) simulations to determine the relationship between dissection propagation in the distal longitudinal direction (the tearing force) and dp/dt...
Endovascular repair of thoracoabdominal aneurysms: design options, device construct, patient selection and complicationsL M Reilly
Division of Vascular Surgery, University of California San Francisco, CA 94143, USA
J Cardiovasc Surg (Torino) 50:447-60. 2009..These results support expanding the indications for endovascular TAAA repair to include standard risk patients...
Acute type A aortic dissection intimal tears by 64-slice computed tomography: a role for endovascular stent-grafting?N Jaussaud
Division of Cardiothoracic Surgery, Department of Surgery, University of California at San Francisco Medical Center and San Francisco Veterans Affairs Medical Center, San Francisco, CA, USA
J Cardiovasc Surg (Torino) 54:373-81. 2013..Available stents used to treat type B aortic dissection do not address anatomic constraints present in type A aortic dissection in the majority of cases, such that development of new devices would be required...
Double-barrel technique for preservation of aortic arch branches during thoracic endovascular aortic repairZ K Baldwin
Division of Vascular Surgery, Department of Surgery, University of California San Francisco, San Francisco, CA 94143, USA
Ann Vasc Surg 22:703-9. 2008..Moreover, the technique uses commercially available devices and permits complete aortic arch coverage (zone 0) without a sternotomy. Although initial outcomes are encouraging, long-term durability remains unknown...
Zenith abdominal aortic aneurysm endovascular graftRoy K Greenberg
Department of Vascular and Cardiothoracic Surgery and Biomedical Engineering, Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA
J Vasc Surg 48:1-9. 2008..The safety and efficacy of the Zenith (Cook Inc, Bloomington, Ind) endovascular graft was assessed based on the United States multicenter trial through 5 years of follow-up...
Spinal arterial anatomy and risk factors for lower extremity weakness following endovascular thoracoabdominal aortic aneurysm repair with branched stent-graftsCatherine K Chang
Department of Surgery, Division of Vascular Surgery, University of California at San Francisco, CA 94143 0222, USA
J Endovasc Ther 15:356-62. 2008..To evaluate spinal arterial anatomy and identify risk factors for lower extremity weakness (LEW) following endovascular thoracoabdominal aortic aneurysm (TAAA) repair...
Redefining postoperative surveillance after endovascular aneurysm repair: recommendations based on 5-year follow-up in the US Zenith multicenter trialW Charles Sternbergh
Ochsner Clinic Foundation, New Orleans, LA 70121, USA
J Vasc Surg 48:278-84; discussion 284-5. 2008..However, there are scant data to support modulation of current post-EVAR surveillance regimens...
Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conferenceFrank J Veith
Montefiore Medical Center/Albert Einstein College of Medicine, 111 E 210th Street, New York, NY 10467, USA
J Vasc Surg 35:1029-35. 2002..These and other conclusions will help to resolve controversy and aid in the management of these vexing complications and should also point the way to future research in this field...
Double-barrel technique for endovascular exclusion of an aortic arch aneurysm without sternotomyZachary K Baldwin
Department of Surgery, Division of Vascular Surgery, University of California at San Francisco, San Francisco, California 94143, USA
J Endovasc Ther 15:161-5. 2008..To report the use of commercially available stents and a stent-graft in coaxial orientation to extend the proximal limits of endografting within the aortic arch...
Computational fluid dynamics within bifurcated abdominal aortic stent-graftsBenjamin A Howell
Division of Vascular Surgery, University of California at San Francisco, California 94143, USA
J Endovasc Ther 14:138-43. 2007..To assess the hemodynamic forces on a bifurcated abdominal aortic stent-graft under realistic conditions of flow, blood pressure, and sac pressure...
Impact of gender on the outcome of endovascular aortic aneurysm repair using the Zenith stent-graft: midterm resultsBeate Hugl
Section of Vascular Surgery, Mayo Clinic Jacksonville, Florida 32224, USA
J Endovasc Ther 14:115-21. 2007..To analyze the 2-year outcomes of female patients after endovascular aortic aneurysm repair (EVAR) with the Zenith AAA Endovascular Graft...
Integrated fellowship in vascular surgery and intervention radiology: a new paradigm in vascular trainingLouis M Messina
Divisions of Vascular Surgery and Interventional Radiology, University of California San Francisco, San Francisco, California 94143, USA
Ann Surg 236:408-414; discussion 414-5. 2002..To evaluate an integrated fellowship in vascular surgery and interventional radiology initiated to train vascular surgeons in endovascular techniques and to train radiology fellows in clinical aspects of vascular diseases...
Lessons learned from the long-term follow-up of a first-generation aortic stent graftPierre Alric
Divisions of Vascular Surgery and Radiology, Nottingham University Hospital, Nottingham, United Kingdom
J Vasc Surg 37:367-73. 2003..No studies have a complete follow-up of more than 4 years. Our study objective was to assess the long-term results and the durability of a first-generation stent graft with complete 7-year follow-up...
A modular multi-branched system for endovascular repair of bilateral common iliac artery aneurysmsCherrie Z Abraham
Division of Vascular Surgery, University of California, San Francisco, California, USA
J Endovasc Ther 10:203-7. 2003..CONCLUSIONS: Endovascular repair of bilateral iliac aneurysm is feasible using a modular stent-graft with separate branches to the internal and external iliac arteries...
Is cross-femoral bypass grafting a disadvantage of aortomonoiliac endovascular aortic aneurysm repair?Lâl P K Yilmaz
Department of Surgery, University of California San Francisco, 505 Parnassus Avenue, San Francisco, CA 94143, USA
J Vasc Surg 38:753-7. 2003..To determine the durability of CFBG in this setting, we examined data from 148 consecutive high-risk patients in a clinical trial of EVAR with a custom-made aortomonoiliac endovascular stent graft...
Branched endovascular repair of aortic arch aneurysm with a modular stent-graft systemDarren B Schneider
Division of Vascular Surgery, University of California-San Francisco, San Francisco, CA, USA
J Vasc Surg 38:855. 2003
Influence of endograft oversizing on device migration, endoleak, aneurysm shrinkage, and aortic neck dilation: results from the Zenith Multicenter TrialW Charles Sternbergh
Vascular Surgery Program, Ochsner Clinic Foundation, 1514 Jefferson Highway, New Orleans, LA 70121, USA
J Vasc Surg 39:20-6. 2004..Effects of variable oversizing of endografts with suprarenal fixation have been poorly studied...
Zenith AAA endovascular graft: intermediate-term results of the US multicenter trialRoy K Greenberg
Division of Vascular Surgery, The Cleveland Clinic Foundation, Cleveland, OH 44195, USA
J Vasc Surg 39:1209-18. 2004..The intent of this study was to assess the safety and effectiveness of the Zenith AAA Endovascular Graft compared with conventional aneurysm repair...
Analysis of renal function after aneurysm repair with a device using suprarenal fixation (Zenith AAA Endovascular Graft) in contrast to open surgical repairRoy K Greenberg
Division of Vascular Surgery, The Cleveland Clinic Foundation, Cleveland, OH 44195, USA
J Vasc Surg 39:1219-28. 2004..This study was undertaken to assess the effect on renal function of open surgery and endovascular abdominal aortic aneurysm (AAA) repair with suprarenal fixation with the Zenith device...
Branched stent-grafts for endovascular repair of aortic and iliac aneurysmsTimothy A M Chuter
UCSF, Division of Vascular Surgery, San Francisco, CA 94143, USA
Tech Vasc Interv Radiol 8:56-60. 2005....
Endovascular repair of an actively hemorrhaging gunshot injury to the abdominal aortaMichael W Yeh
Department of Surgery, San Francisco General Hospital, University of California San Francisco, CA 94110, USA
J Vasc Surg 42:1007-9. 2005..Endovascular approaches to aortic injuries may be valuable in settings where a hostile abdomen precludes traditional open repair...
A double-barrel stent-graft for endovascular repair of the aortic archJade S Hiramoto
Division of Vascular Surgery, University of California San Francisco, California 94143 0222, USA
J Endovasc Ther 13:72-6. 2006..To extend the role of endovascular aneurysm repair in the presence of angulation and dilatation of the distal arch that compromise the proximal implantation site...
Adjunctive primary stenting of Zenith endograft limbs during endovascular abdominal aortic aneurysm repair: implications for limb patencyNayan Sivamurthy
Division of Vascular Surgery, University of California San Francisco Medical Center, 94143-0222, USA
J Vasc Surg 43:662-70. 2006..Based on these findings, we believe one should identify and stent any limbs that appear to be at risk for thrombosis, but this study lacks the data to predict which limbs need stenting...
Long-term outcome and reintervention after endovascular abdominal aortic aneurysm repair using the Zenith stent graftJade S Hiramoto
Division of Vascular Surgery, University of California San Francisco, San Francisco, CA, 94143, USA
J Vasc Surg 45:461-5; discussion 465-6. 2007..To assess the long-term performance of the bifurcated Zenith stent graft...
The effect of magnetic resonance imaging on stainless-steel Z-stent-based abdominal aortic prosthesisJade S Hiramoto
Division of Vascular Surgery, University of California San Francisco, San Francisco, CA 94143, USA
J Vasc Surg 45:472-4. 2007..To assess the effects of magnetic resonance imaging (MRI) on stainless-steel Z-stent-based abdominal aortic prostheses...
Abdominal aortic aneurysm repair with the Zenith stent graft: short to midterm resultsCherrie Z Abraham
Division of Vascular Surgery, University of California, San Francisco, CA, USA
J Vasc Surg 36:217-24; discussion 224-5. 2002..CONCLUSION: The Zenith device is safe, versatile, and effective in the short to medium term. Most patients need wide stent grafts (>or=28 mm proximally and >or=16 mm distally) to achieve 10% to 20% oversizing to prevent type I endoleak...
