P Pat Banerjee

Summary

Affiliation: University of Illinois at Chicago
Country: USA

Publications

  1. ncbi request reprint Virtual reality and haptic interface for cellular injection simulation
    P Pat Banerjee
    Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA
    Stud Health Technol Inform 125:37-9. 2007
  2. ncbi request reprint Virtual reality simulations
    P Pat Banerjee
    Department of Mechanical and Industrial Engineering M C 251, University of Illinois Chicago, 3029 Engineering Research Facility, 842 West Taylor Street, Chicago, IL 60607, USA
    Anesthesiol Clin 25:337-48. 2007
  3. ncbi request reprint Accuracy of ventriculostomy catheter placement using a head- and hand-tracked high-resolution virtual reality simulator with haptic feedback
    P Pat Banerjee
    Department of Mechanical and Industrial Engineering, College of Engineering, University of Illinois at Chicago 60607, USA
    J Neurosurg 107:515-21. 2007
  4. ncbi request reprint Virtual reality in neurosurgical education: part-task ventriculostomy simulation with dynamic visual and haptic feedback
    G Michael Lemole
    Department of Neurosurgery, University of Illinois, Chicago, Chicago, Illinois 60612, USA
    Neurosurgery 61:142-8; discussion 148-9. 2007
  5. doi request reprint Percutaneous spinal fixation simulation with virtual reality and haptics
    Cristian J Luciano
    Department of Mechanical and Industrial Engineering, College of Engineering, University of Illinois at Chicago, Chicago, Illinois 60607, USA
    Neurosurgery 72:89-96. 2013
  6. ncbi request reprint Concurrent and face validity of a capsulorhexis simulation with respect to human patients
    P Pat Banerjee
    Mechanical and Industrial Engineering, University of Illinois at Chicago, IL, USA
    Stud Health Technol Inform 173:35-41. 2012
  7. pmc Virtual reality cerebral aneurysm clipping simulation with real-time haptic feedback
    Ali Alaraj
    Department of Neurosurgery, University of Illinois College of Medicine at Chicago, Chicago, Illinois Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, Illinois ImmersiveTouch, Inc, Westmont, Illinois College of Engineering, University of Illinois at Chicago, Chicago, Illinois Division of Neurosurgery, Department of Surgery, University of Chicago, Chicago, Illinois and Department of Neurosurgery, Weill Cornell Medical College, New York
    Neurosurgery 11:52-8. 2015
  8. doi request reprint Virtual ventriculostomy with 'shifted ventricle': neurosurgery resident surgical skill assessment using a high-fidelity haptic/graphic virtual reality simulator
    Michael Lemole
    Department of Neurosurgery, University of Illinois, Chicago, IL 60607, USA
    Neurol Res 31:430-1. 2009
  9. pmc Learning retention of thoracic pedicle screw placement using a high-resolution augmented reality simulator with haptic feedback
    Cristian J Luciano
    Department of Mechanical and Industrial Engineering, College of Engineering, University of Illinois at Chicago, Illinois 60607, USA
    Neurosurgery 69:ons14-9; discussion ons19. 2011
  10. doi request reprint A high performance graphic and haptic curvilinear capsulorrhexis simulation system
    Shun Liang
    Department of Computer Science, University of Illinois at Chicago, Chicago, IL 60607 USA
    Conf Proc IEEE Eng Med Biol Soc 2009:5092-5. 2009

Collaborators

Detail Information

Publications12

  1. ncbi request reprint Virtual reality and haptic interface for cellular injection simulation
    P Pat Banerjee
    Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA
    Stud Health Technol Inform 125:37-9. 2007
    ..A collocated graphic/haptic working volume provides a realistic visual and force feedback to guide the user in performing a cell injection procedure. A preliminary experiment shows promising results...
  2. ncbi request reprint Virtual reality simulations
    P Pat Banerjee
    Department of Mechanical and Industrial Engineering M C 251, University of Illinois Chicago, 3029 Engineering Research Facility, 842 West Taylor Street, Chicago, IL 60607, USA
    Anesthesiol Clin 25:337-48. 2007
    ..A new prototype device invented by the authors, known as ImmersiveTouch, addresses how to overcome these technologic limitations...
  3. ncbi request reprint Accuracy of ventriculostomy catheter placement using a head- and hand-tracked high-resolution virtual reality simulator with haptic feedback
    P Pat Banerjee
    Department of Mechanical and Industrial Engineering, College of Engineering, University of Illinois at Chicago 60607, USA
    J Neurosurg 107:515-21. 2007
    ..The purpose of this study was to evaluate the accuracy of ventriculostomy catheter placement on a head- and hand-tracked high-resolution and high-performance virtual reality and haptic technology workstation...
  4. ncbi request reprint Virtual reality in neurosurgical education: part-task ventriculostomy simulation with dynamic visual and haptic feedback
    G Michael Lemole
    Department of Neurosurgery, University of Illinois, Chicago, Chicago, Illinois 60612, USA
    Neurosurgery 61:142-8; discussion 148-9. 2007
    ..Most neurosurgical procedures can be conceptualized and segmented into critical task components, which can be simulated independently or in conjunction with other modules to recreate the experience of a complex neurosurgical procedure...
  5. doi request reprint Percutaneous spinal fixation simulation with virtual reality and haptics
    Cristian J Luciano
    Department of Mechanical and Industrial Engineering, College of Engineering, University of Illinois at Chicago, Chicago, Illinois 60607, USA
    Neurosurgery 72:89-96. 2013
    ..In this study, we evaluated the use of a part-task simulator with 3-dimensional and haptic feedback as a training tool for percutaneous spinal needle placement...
  6. ncbi request reprint Concurrent and face validity of a capsulorhexis simulation with respect to human patients
    P Pat Banerjee
    Mechanical and Industrial Engineering, University of Illinois at Chicago, IL, USA
    Stud Health Technol Inform 173:35-41. 2012
    ....
  7. pmc Virtual reality cerebral aneurysm clipping simulation with real-time haptic feedback
    Ali Alaraj
    Department of Neurosurgery, University of Illinois College of Medicine at Chicago, Chicago, Illinois Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, Illinois ImmersiveTouch, Inc, Westmont, Illinois College of Engineering, University of Illinois at Chicago, Chicago, Illinois Division of Neurosurgery, Department of Surgery, University of Chicago, Chicago, Illinois and Department of Neurosurgery, Weill Cornell Medical College, New York
    Neurosurgery 11:52-8. 2015
    ....
  8. doi request reprint Virtual ventriculostomy with 'shifted ventricle': neurosurgery resident surgical skill assessment using a high-fidelity haptic/graphic virtual reality simulator
    Michael Lemole
    Department of Neurosurgery, University of Illinois, Chicago, IL 60607, USA
    Neurol Res 31:430-1. 2009
    ..Furthermore, the significant improvement observed by the second attempt implies that the learning curve has been affected and the process 'jump started'...
  9. pmc Learning retention of thoracic pedicle screw placement using a high-resolution augmented reality simulator with haptic feedback
    Cristian J Luciano
    Department of Mechanical and Industrial Engineering, College of Engineering, University of Illinois at Chicago, Illinois 60607, USA
    Neurosurgery 69:ons14-9; discussion ons19. 2011
    ..We evaluated the use of a part-task simulator with 3D and haptic feedback as a training tool for a common neurosurgical procedure--placement of thoracic pedicle screws...
  10. doi request reprint A high performance graphic and haptic curvilinear capsulorrhexis simulation system
    Shun Liang
    Department of Computer Science, University of Illinois at Chicago, Chicago, IL 60607 USA
    Conf Proc IEEE Eng Med Biol Soc 2009:5092-5. 2009
    ..Promising evaluation results from a group of ophthalmology residents and attending surgeons are presented and discussed...
  11. pmc Virtual reality training in neurosurgery: Review of current status and future applications
    Ali Alaraj
    Department of Neurosurgery, University of Illinois at Chicago College of Medicine, Chicago, USA
    Surg Neurol Int 2:52. 2011
    ..Early systems have demonstrated their effectiveness and discriminative ability. Newer systems enable the development of comprehensive curricula and full procedural simulations...
  12. doi request reprint Comparison of the anterior capsulotomy edge created by manual capsulorhexis and 2 femtosecond laser platforms: Scanning electron microscopy study
    Khaled Al Harthi
    From the King Khaled Eye Specialist Hospital Al Harthi, Al Shahwan, Al Towerki, Behrens, Edward, Riyadh, Kingdom of Saudi Arabia the Department of Mechanical and Industrial Engineering Banerjee, University of Illinois at Chicago, Chicago, Illinois, and the Wilmer Eye Institute Behrens, Edward, Johns Hopkins University, Baltimore, Maryland, USA
    J Cataract Refract Surg 40:2106-12. 2014
    ..To compare the scanning electron microscopy (SEM) features of the anterior capsule edge created by continuous curvilinear capsulorhexis (CCC) and femtosecond laser-assisted capsulotomy using angular second moment and contrast...