Vincent L Pisacane

Summary

Affiliation: United States Naval Academy
Country: USA

Publications

  1. ncbi request reprint Thermoregulatory models of space shuttle and space station activities
    Vincent L Pisacane
    United States Naval Academy, Annapolis, MD, USA
    Aviat Space Environ Med 78:A48-55. 2007
  2. doi request reprint End-to-end system test for solid-state microdosemeters
    V L Pisacane
    United States Naval Academy, Aerospace Engineering Department Mail Stop 11B, 590 Holloway Road, Annapolis, MD 21402 5042, USA
    Radiat Prot Dosimetry 140:309-18. 2010
  3. doi request reprint Microdosemeter instrument (MIDN) for assessing risk in space
    V L Pisacane
    Aerospace Engineering Department Mail Stop 11B, United States Naval Academy, 590 Holloway Road, Annapolis, MD 21402 5042, USA
    Radiat Prot Dosimetry 143:398-401. 2011
  4. doi request reprint Microdosimetric comparison of scanned and conventional proton beams used in radiation therapy
    John F Dicello
    Department of Radiation Medicine, Loma Linda University Medical Center, 25 Westminster Bridge Way, Timonium, MD, USA
    Radiat Prot Dosimetry 143:513-8. 2011

Detail Information

Publications4

  1. ncbi request reprint Thermoregulatory models of space shuttle and space station activities
    Vincent L Pisacane
    United States Naval Academy, Annapolis, MD, USA
    Aviat Space Environ Med 78:A48-55. 2007
    ....
  2. doi request reprint End-to-end system test for solid-state microdosemeters
    V L Pisacane
    United States Naval Academy, Aerospace Engineering Department Mail Stop 11B, 590 Holloway Road, Annapolis, MD 21402 5042, USA
    Radiat Prot Dosimetry 140:309-18. 2010
    ..This technique may be utilised to calibrate both a solid-state microdosemeter and, with modification, a TEPC with the higher average ionisation energy of a gas...
  3. doi request reprint Microdosemeter instrument (MIDN) for assessing risk in space
    V L Pisacane
    Aerospace Engineering Department Mail Stop 11B, United States Naval Academy, 590 Holloway Road, Annapolis, MD 21402 5042, USA
    Radiat Prot Dosimetry 143:398-401. 2011
    ..An early prototype in 2007 was successfully launched, the only solid-state microdosemeter to have flown in space...
  4. doi request reprint Microdosimetric comparison of scanned and conventional proton beams used in radiation therapy
    John F Dicello
    Department of Radiation Medicine, Loma Linda University Medical Center, 25 Westminster Bridge Way, Timonium, MD, USA
    Radiat Prot Dosimetry 143:513-8. 2011
    ..Dosimetric measurements and microdosimetric distributions for a scanned beam are presented and compared with beams produced with the conventional methods presently used in proton therapy...