  1. ncbi request reprint Linearity and uniformity response as an indicator of performance for Agfa ADC-MD10 computed radiography plates
    John R Zullo
    Radiation Physics, University of Texas M D Anderson Cancer Center, Houston, Texas 77030, USA
    Med Dosim 29:118-21. 2004
  2. ncbi request reprint Implication of CT table sag on geometrical accuracy during virtual simulation
    John R Zullo
    Radiation Physics, University of Texas M D Anderson Cancer Center, Houston, TX 77030, USA
    Med Dosim 32:233-6. 2007
  3. ncbi request reprint An overview of the comprehensive proton therapy machine quality assurance procedures implemented at The University of Texas M. D. Anderson Cancer Center Proton Therapy Center-Houston
    Bijan Arjomandy
    Department of Radiation Physics, The University of Texas M D Anderson Cancer Center, 1840 Old Spanish Trail, Houston, Texas 77025, USA
    Med Phys 36:2269-82. 2009
  4. doi request reprint LiF TLD-100 as a dosimeter in high energy proton beam therapy--can it yield accurate results?
    John R Zullo
    The University of Texas M D Anderson Cancer Center, Houston, TX, USA
    Med Dosim 35:63-6. 2010
  5. doi request reprint Measurement of neutron dose equivalent and its dependence on beam configuration for a passive scattering proton delivery system
    Xin Wang
    Department of Radiation Physics, The University of Texas M D Anderson Cancer Center, Houston, TX 77030, USA
    Int J Radiat Oncol Biol Phys 76:1563-70. 2010

Detail Information

Publications5

  1. ncbi request reprint Linearity and uniformity response as an indicator of performance for Agfa ADC-MD10 computed radiography plates
    John R Zullo
    Radiation Physics, University of Texas M D Anderson Cancer Center, Houston, Texas 77030, USA
    Med Dosim 29:118-21. 2004
    ..Additional research is currently underway to evaluate various other methods of assessing CR plate performance...
  2. ncbi request reprint Implication of CT table sag on geometrical accuracy during virtual simulation
    John R Zullo
    Radiation Physics, University of Texas M D Anderson Cancer Center, Houston, TX 77030, USA
    Med Dosim 32:233-6. 2007
    ..In addition, the amount of sag should be measured under a clinically representative weight load upon CT-simulator commissioning...
  3. ncbi request reprint An overview of the comprehensive proton therapy machine quality assurance procedures implemented at The University of Texas M. D. Anderson Cancer Center Proton Therapy Center-Houston
    Bijan Arjomandy
    Department of Radiation Physics, The University of Texas M D Anderson Cancer Center, 1840 Old Spanish Trail, Houston, Texas 77025, USA
    Med Phys 36:2269-82. 2009
    ..This article describes these procedures and can be used by others as a guideline for developing QA procedures based on particle accelerator specific parameters and local regulations pertinent to any new facility...
  4. doi request reprint LiF TLD-100 as a dosimeter in high energy proton beam therapy--can it yield accurate results?
    John R Zullo
    The University of Texas M D Anderson Cancer Center, Houston, TX, USA
    Med Dosim 35:63-6. 2010
    ..Thus, the rapid change in stopping power ratios at the end of the range should not affect such measurements, and TLD-100 may be used with confidence as an in vivo dosimeter for proton beam therapy...
  5. doi request reprint Measurement of neutron dose equivalent and its dependence on beam configuration for a passive scattering proton delivery system
    Xin Wang
    Department of Radiation Physics, The University of Texas M D Anderson Cancer Center, Houston, TX 77030, USA
    Int J Radiat Oncol Biol Phys 76:1563-70. 2010
    ....