Gregory Boverman

Summary

Affiliation: Rensselaer Polytechnic Institute
Country: USA

Publications

  1. ncbi request reprint Spatio-temporal imaging of the hemoglobin in the compressed breast with diffuse optical tomography
    Gregory Boverman
    Biomedical Engineering Department, Rensselaer Polytechnic Institute, Jonsson Engineering Center, Troy, NY 12180, USA
    Phys Med Biol 52:3619-41. 2007
  2. ncbi request reprint The complete electrode model for imaging and electrode contact compensation in electrical impedance tomography
    Gregory Boverman
    Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
    Conf Proc IEEE Eng Med Biol Soc 2007:3462-5. 2007
  3. pmc Estimation and statistical bounds for three-dimensional polar shapes in diffuse optical tomography
    Gregory Boverman
    Biomedical Engineering Department, Rensselaer Polytechnic Institute, 7046 Jonsson Engineering Center, Troy, NY 12180, USA
    IEEE Trans Med Imaging 27:752-65. 2008
  4. pmc Regional admittivity spectra with tomosynthesis images for breast cancer detection: preliminary patient study
    Tzu Jen Kao
    Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
    IEEE Trans Med Imaging 27:1762-8. 2008
  5. pmc A two-layered forward model of tissue for electrical impedance tomography
    Rujuta Kulkarni
    Department of Electrical, Computer and Systems Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
    Physiol Meas 30:S19-34. 2009
  6. ncbi request reprint Regional admittivity spectra with tomosynthesis images for breast cancer detection
    Tzu Jen Kao
    Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
    Conf Proc IEEE Eng Med Biol Soc 2007:4142-5. 2007
  7. pmc An analytical layered forward model for breasts in electrical impedance tomography
    Rujuta Kulkarni
    Department of Electrical, Computer, and Systems Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
    Physiol Meas 29:S27-40. 2008
  8. ncbi request reprint Layered model for breasts in electrical impedance tomography
    Rujuta Kulkarni
    Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
    Conf Proc IEEE Eng Med Biol Soc 2007:4150-3. 2007
  9. pmc The complete electrode model for EIT in a mammography geometry
    Bong Seok Kim
    Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
    Physiol Meas 28:S57-69. 2007
  10. pmc Robust linearized image reconstruction for multifrequency EIT of the breast
    Gregory Boverman
    Information Sciences Institute, University of Southern California, 3811 N Fairfax Drive, Arlington, VA 22203, USA
    IEEE Trans Med Imaging 27:1439-48. 2008

Detail Information

Publications11

  1. ncbi request reprint Spatio-temporal imaging of the hemoglobin in the compressed breast with diffuse optical tomography
    Gregory Boverman
    Biomedical Engineering Department, Rensselaer Polytechnic Institute, Jonsson Engineering Center, Troy, NY 12180, USA
    Phys Med Biol 52:3619-41. 2007
    ..We are able to quantify the global return of blood to the breast following compression, and, in addition, localized changes are observed which correspond to the glandular region of the breast...
  2. ncbi request reprint The complete electrode model for imaging and electrode contact compensation in electrical impedance tomography
    Gregory Boverman
    Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
    Conf Proc IEEE Eng Med Biol Soc 2007:3462-5. 2007
    ..Results show that, using this procedure, artifacts due to electrodes making poor contact can be greatly reduced...
  3. pmc Estimation and statistical bounds for three-dimensional polar shapes in diffuse optical tomography
    Gregory Boverman
    Biomedical Engineering Department, Rensselaer Polytechnic Institute, 7046 Jonsson Engineering Center, Troy, NY 12180, USA
    IEEE Trans Med Imaging 27:752-65. 2008
    ..82 cm(3) with errors of less than 10% in object volume and absorption contrast. We also investigate the robustness of our shape-based reconstruction approach to a violation of the assumption that the medium is purely piecewise constant...
  4. pmc Regional admittivity spectra with tomosynthesis images for breast cancer detection: preliminary patient study
    Tzu Jen Kao
    Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
    IEEE Trans Med Imaging 27:1762-8. 2008
    ..Localization of these lesions is confirmed by simultaneous, in register digital breast tomosynthesis (DBT) mammography or 3-D mammograms...
  5. pmc A two-layered forward model of tissue for electrical impedance tomography
    Rujuta Kulkarni
    Department of Electrical, Computer and Systems Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
    Physiol Meas 30:S19-34. 2009
    ....
  6. ncbi request reprint Regional admittivity spectra with tomosynthesis images for breast cancer detection
    Tzu Jen Kao
    Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
    Conf Proc IEEE Eng Med Biol Soc 2007:4142-5. 2007
    ..These findings are confirmed by simultaneous, co-registered 3-D mammograms or tomosynthesis images and are verified with biopsy reports...
  7. pmc An analytical layered forward model for breasts in electrical impedance tomography
    Rujuta Kulkarni
    Department of Electrical, Computer, and Systems Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
    Physiol Meas 29:S27-40. 2008
    ..Lastly, we demonstrate the improvement that the layered forward model produces over the homogeneous model when working with clinical data...
  8. ncbi request reprint Layered model for breasts in electrical impedance tomography
    Rujuta Kulkarni
    Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
    Conf Proc IEEE Eng Med Biol Soc 2007:4150-3. 2007
    ..We also demonstrate the improvement in reconstruction of a target embedded in a layered body when the homogeneous forward solution is replaced by the layered forward solution...
  9. pmc The complete electrode model for EIT in a mammography geometry
    Bong Seok Kim
    Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
    Physiol Meas 28:S57-69. 2007
    ..The experimental results show an improvement in both forward modeling accuracy and in the quality of the resulting reconstructed images using the complete electrode model, as compared to the ave-gap model...
  10. pmc Robust linearized image reconstruction for multifrequency EIT of the breast
    Gregory Boverman
    Information Sciences Institute, University of Southern California, 3811 N Fairfax Drive, Arlington, VA 22203, USA
    IEEE Trans Med Imaging 27:1439-48. 2008
    ..Initial clinical results are presented, showing the potential of our algorithms to detect and localize breast tumors...
  11. ncbi request reprint Quantitative spectroscopic diffuse optical tomography of the breast guided by imperfect a priori structural information
    Gregory Boverman
    Department of Electrical and Computer Engineering, Northeastern University, 302 Stearns Hall, Boston, MA 02115, USA
    Phys Med Biol 50:3941-56. 2005
    ..In addition, we examine the consequences which errors in the breast segmentation have on estimating both the background and inhomogeneity chromophore concentrations...