  1. pmc A hybrid PDMS-Parylene subdural multi-electrode array
    Manuel Ochoa
    School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47907, USA
    Biomed Microdevices 15:437-43. 2013
  2. doi request reprint Polymeric microdevices for transdermal and subcutaneous drug delivery
    Manuel Ochoa
    School of Electrical and Computer Engineering, Birck Nanotechnology Center, Purdue University, West Lafayette, IN 47907, USA
    Adv Drug Deliv Rev 64:1603-16. 2012
  3. ncbi request reprint A fermentation-powered thermopneumatic pump for biomedical applications
    Manuel Ochoa
    School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47907, USA
    Lab Chip 12:4044-8. 2012
  4. doi request reprint A skin-contact-actuated micropump for transdermal drug delivery
    Charilaos Mousoulis
    School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47906, USA
    IEEE Trans Biomed Eng 58:1492-8. 2011
  5. pmc Analysis of novel methods to determine the accuracy of the OmniPod insulin pump: a key component of the artificial pancreas system
    Manuel Ochoa
    Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907, USA
    J Diabetes Sci Technol 5:1519-20. 2011

Collaborators

  • Kevin J Otto
  • Charilaos Mousoulis
  • Babak Ziaie
  • Demetrios Papageorgiou

Detail Information

Publications5

  1. pmc A hybrid PDMS-Parylene subdural multi-electrode array
    Manuel Ochoa
    School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47907, USA
    Biomed Microdevices 15:437-43. 2013
    ..Acoustically evoked neural activity was successfully recorded from rat auditory cortex, confirming in vivo functionality...
  2. doi request reprint Polymeric microdevices for transdermal and subcutaneous drug delivery
    Manuel Ochoa
    School of Electrical and Computer Engineering, Birck Nanotechnology Center, Purdue University, West Lafayette, IN 47907, USA
    Adv Drug Deliv Rev 64:1603-16. 2012
    ....
  3. ncbi request reprint A fermentation-powered thermopneumatic pump for biomedical applications
    Manuel Ochoa
    School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47907, USA
    Lab Chip 12:4044-8. 2012
    ..A polymeric prototype (dimensions 15 mm × 15 mm × 10 mm) with a slow flow rate of <0.23 μL min(-1) and maximum backpressure of 5.86 kPa capable of continuously pumping for over two hours is presented and characterized...
  4. doi request reprint A skin-contact-actuated micropump for transdermal drug delivery
    Charilaos Mousoulis
    School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47906, USA
    IEEE Trans Biomed Eng 58:1492-8. 2011
    ..A prototype device with overall dimensions of 14 mm × 14 mm × 8 mm is fabricated and characterized. For a perfluoro compound working fluid (3M FC-3284), a flow rate of 28.8 μ L/min and a maximum back pressure of 28.9 kPa is measured...
  5. pmc Analysis of novel methods to determine the accuracy of the OmniPod insulin pump: a key component of the artificial pancreas system
    Manuel Ochoa
    Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana 47907, USA
    J Diabetes Sci Technol 5:1519-20. 2011
    ..Both methods produce accurate measurements for doses >0.2 U, and the latter method is especially appropriate for doses <0.2 U, with accuracies down to 0.9%...