P B Kingsley

Summary

Affiliation: North Shore University Hospital
Country: USA

Publications

  1. ncbi request reprint Correction of errors caused by imperfect inversion pulses in MR imaging measurement of T1 relaxation times
    P B Kingsley
    Department of Radiology, North Shore University Hospital, Manhasset, NY 11030, USA
    Magn Reson Imaging 16:1049-55. 1998
  2. ncbi request reprint Corrections for off-resonance effects and incomplete saturation in conventional (two-site) saturation-transfer kinetic measurements
    P B Kingsley
    Department of Radiology, North Shore University Hospital, Manhasset, New York 11030, USA
    Magn Reson Med 43:810-9. 2000
  3. ncbi request reprint Correcting for incomplete saturation and off-resonance effects in multiple-site saturation-transfer kinetic measurements
    P B Kingsley
    Department of Radiology, North Shore University Hospital, 300 Community Drive, Manhasset, New York, 11030 USA
    J Magn Reson 146:100-9. 2000
  4. ncbi request reprint Effect of increased repetition time TR on precision of inversion-recovery T(1) measurements
    P B Kingsley
    Department of Radiology, North Shore University Hospital, 300 Community Drive, Manhasset, NY 11030, USA
    Magn Reson Imaging 19:279-82. 2001

Collaborators

Detail Information

Publications4

  1. ncbi request reprint Correction of errors caused by imperfect inversion pulses in MR imaging measurement of T1 relaxation times
    P B Kingsley
    Department of Radiology, North Shore University Hospital, Manhasset, NY 11030, USA
    Magn Reson Imaging 16:1049-55. 1998
    ..Phantom accuracy does not ensure accuracy in vivo, because phantoms may have a more homogeneous B1 field and a longer T2 than do biological samples...
  2. ncbi request reprint Corrections for off-resonance effects and incomplete saturation in conventional (two-site) saturation-transfer kinetic measurements
    P B Kingsley
    Department of Radiology, North Shore University Hospital, Manhasset, New York 11030, USA
    Magn Reson Med 43:810-9. 2000
    ..More accurate formulas are available if signal intensities and relaxation rates can be measured while the exchange process is stopped. Magn Reson Med 43:810-819, 2000...
  3. ncbi request reprint Correcting for incomplete saturation and off-resonance effects in multiple-site saturation-transfer kinetic measurements
    P B Kingsley
    Department of Radiology, North Shore University Hospital, 300 Community Drive, Manhasset, New York, 11030 USA
    J Magn Reson 146:100-9. 2000
    ..Exact formulas are available for three exchanging sites with incomplete saturation if there are no off-resonance effects. Off-resonance corrections are imperfect even with complete saturation...
  4. ncbi request reprint Effect of increased repetition time TR on precision of inversion-recovery T(1) measurements
    P B Kingsley
    Department of Radiology, North Shore University Hospital, 300 Community Drive, Manhasset, NY 11030, USA
    Magn Reson Imaging 19:279-82. 2001
    ....