  1. doi request reprint The NIST radioactivity measurement assurance program for the radiopharmaceutical industry
    Jeffrey T Cessna
    Physical Measurement Laboratory, National Institute of Standards and Technology, 100 Bureau Dr, Gaithersburg, MD 20899, USA
    Appl Radiat Isot 70:2227-31. 2012
  2. ncbi request reprint Standardization of radium-223 by liquid scintillation counting
    J T Cessna
    Ionizing Radiation Division, Physics Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899 8462, USA
    Appl Radiat Isot 68:1523-8. 2010
  3. ncbi request reprint Experimental determination of calibration settings for plastic syringes containing solutions of 90Y using commercial radionuclide calibrators
    B E Zimmerman
    Ionizing Radiation Division, National Institute of Standards and Technology, Department of Physics Laboratory, 100 Bureau Drive, Gaithersburg, MD 20899 8462, USA
    Appl Radiat Isot 60:511-7. 2004
  4. ncbi request reprint The standardization of 62Cu and experimental determinations of dose calibrator settings for generator-produced 62CuPTSM
    B E Zimmerman
    Physics Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
    Appl Radiat Isot 51:515-26. 1999
  5. doi request reprint Results of an international comparison for the activity measurement of 177Lu
    B E Zimmerman
    Physical Measurement Laboratory, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD 20899, USA
    Appl Radiat Isot 70:1825-30. 2012
  6. ncbi request reprint Establishment of transfer standard for holmium-166-DOTMP
    J T Cessna
    Ionizing Radiation Division, National Institute of Standards and Technology, 100 Bureau Drive Stop, 8462 Gaithersburg, MD 20899 8462, USA
    Appl Radiat Isot 60:505-10. 2004
  7. ncbi request reprint Construction and implementation of the NIST triple-to-double coincidence ratio (TDCR) spectrometer
    B E Zimmerman
    Ionizing Radiation Division, Physics Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899 8462, USA
    Appl Radiat Isot 60:433-8. 2004
  8. ncbi request reprint Radioassays and experimental evaluation of dose calibrator settings for 18F
    B E Zimmerman
    Physics Laboratory, National Institute of Standards and Technology, Gaithersburg, MD, USA
    Appl Radiat Isot 54:113-22. 2001
  9. ncbi request reprint Development of a calibration methodology for large-volume, solid ⁶⁸Ge phantoms for traceable measurements in positron emission tomography
    B E Zimmerman
    Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899 8462, USA Electronic address
    Appl Radiat Isot 87:5-9. 2014
  10. ncbi request reprint Experimental investigation of dose calibrator response for 125I brachytherapy solutions contained in 5 mL plastic syringes and 2 mL conical glass v-vials as a function of filling mass
    B E Zimmerman
    Physics Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 8462, USA
    Med Phys 29:1547-55. 2002

Detail Information

Publications10

  1. doi request reprint The NIST radioactivity measurement assurance program for the radiopharmaceutical industry
    Jeffrey T Cessna
    Physical Measurement Laboratory, National Institute of Standards and Technology, 100 Bureau Dr, Gaithersburg, MD 20899, USA
    Appl Radiat Isot 70:2227-31. 2012
    ..The percentage of participants results within 10% of NIST ranges from 88% to 98%...
  2. ncbi request reprint Standardization of radium-223 by liquid scintillation counting
    J T Cessna
    Ionizing Radiation Division, Physics Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899 8462, USA
    Appl Radiat Isot 68:1523-8. 2010
    ..55% was achieved. Results were in excellent agreement with confirmatory measurements performed by 2pialpha proportional counting. However, results are not in agreement with methods based on gamma ray measurements...
  3. ncbi request reprint Experimental determination of calibration settings for plastic syringes containing solutions of 90Y using commercial radionuclide calibrators
    B E Zimmerman
    Ionizing Radiation Division, National Institute of Standards and Technology, Department of Physics Laboratory, 100 Bureau Drive, Gaithersburg, MD 20899 8462, USA
    Appl Radiat Isot 60:511-7. 2004
    ..A direct comparison was also made between the actual 90Y Zevalin drug and the "standard" solution, with no differences in determined calibration settings observed within the uncertainties on the activity calibration...
  4. ncbi request reprint The standardization of 62Cu and experimental determinations of dose calibrator settings for generator-produced 62CuPTSM
    B E Zimmerman
    Physics Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
    Appl Radiat Isot 51:515-26. 1999
    ..7% for the syringe and 7.7% for the ampoule, and underscore the need for experimental verification of the dose calibrator settings for each radionuclide and each geometry used in the clinic...
  5. doi request reprint Results of an international comparison for the activity measurement of 177Lu
    B E Zimmerman
    Physical Measurement Laboratory, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD 20899, USA
    Appl Radiat Isot 70:1825-30. 2012
    ..288(4)MBq/g using all eleven results. Degrees of equivalence and their uncertainties were calculated for each laboratory based on the CRV. Most of the values reported by the participating laboratories were within 0.6% of the CRV...
  6. ncbi request reprint Establishment of transfer standard for holmium-166-DOTMP
    J T Cessna
    Ionizing Radiation Division, National Institute of Standards and Technology, 100 Bureau Drive Stop, 8462 Gaithersburg, MD 20899 8462, USA
    Appl Radiat Isot 60:505-10. 2004
    ..7+/-1.3, for the Capintec and AtomLab models, respectively. The calibration factors recommended for an NIST 5-ml ampoule are (686+/-5) x 10 and 70.9+/-0.4 for the Capintec and AtomLab models, respectively...
  7. ncbi request reprint Construction and implementation of the NIST triple-to-double coincidence ratio (TDCR) spectrometer
    B E Zimmerman
    Ionizing Radiation Division, Physics Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899 8462, USA
    Appl Radiat Isot 60:433-8. 2004
    ..TDCR results for a 204Tl solution were in excellent agreement (maximum difference of 0.2% with any other method, with combined standard uncertainty of 0.45% on TDCR result) with results obtained using three other methods...
  8. ncbi request reprint Radioassays and experimental evaluation of dose calibrator settings for 18F
    B E Zimmerman
    Physics Laboratory, National Institute of Standards and Technology, Gaithersburg, MD, USA
    Appl Radiat Isot 54:113-22. 2001
    ....
  9. ncbi request reprint Development of a calibration methodology for large-volume, solid ⁶⁸Ge phantoms for traceable measurements in positron emission tomography
    B E Zimmerman
    Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899 8462, USA Electronic address
    Appl Radiat Isot 87:5-9. 2014
    ..1%. Imaging data from the phantoms using a calibrated PET-CT scanner gave values consistent with the calibrated activity concentrations within experimental uncertainties. ..
  10. ncbi request reprint Experimental investigation of dose calibrator response for 125I brachytherapy solutions contained in 5 mL plastic syringes and 2 mL conical glass v-vials as a function of filling mass
    B E Zimmerman
    Physics Laboratory, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 8462, USA
    Med Phys 29:1547-55. 2002
    ....