J W Graves

Summary

Affiliation: Mayo Clinic
Country: USA

Publications

  1. ncbi request reprint The Accoson Greenlight 300, the first non-automated mercury-free blood pressure measurement device to pass the International Protocol for blood pressure measuring devices in adults
    John W Graves
    Department of Internal Medicine, Mayo Clinic and Mayo Foundation, Rochester 55905, USA
    Blood Press Monit 9:13-7. 2004
  2. ncbi request reprint Prevalence of blood pressure cuff sizes in a referral practice of 430 consecutive adult hypertensives
    J W Graves
    Division of Hypertension, Mayo Clinic and Mayo Foundation, Rochester, Minnesota 55905, USA
    Blood Press Monit 6:17-20. 2001
  3. doi request reprint Diagnosis and management of chronic kidney disease
    John W Graves
    Division of Nephrology and Hypertension, Mayo Clinic, 200 First St SW, Rochester, MN 55905, USA
    Mayo Clin Proc 83:1064-9. 2008
  4. ncbi request reprint What is adequate hypertension control? Having your dinner and dessert too
    John W Graves
    Division of Nephrology and Hypertension, Mayo Clinic College of Medicine, Rochester, MN 55905, USA
    Cleve Clin J Med 74:748-54. 2007
  5. ncbi request reprint The impact of observer and patient factors on the occurrence of digit preference for zero in blood pressure measurement in a hypertension specialty clinic: evidence for the need of continued observation
    John W Graves
    Division of Nephrology and Hypertension, Mayo Clinic College of Medicine and Mayo Foundation, 200 First Street SW, Rochester, MN 55905, USA
    Am J Hypertens 19:567-72. 2006
  6. ncbi request reprint The trained observer better predicts daytime ABPM diastolic blood pressure in hypertensive patients than does an automated (Omron) device
    John W Graves
    Division of Nephrology and Hypertension, Mayo Clinic College of Medicine, Rochester, Minnesota 55905, USA
    Blood Press Monit 11:53-8. 2006
  7. ncbi request reprint Limited (6-h) ambulatory blood pressure monitoring is a valid replacement for the office blood pressure by trained nurse clinician in the diagnosis of hypertension
    John W Graves
    Division of Nephrology and Hypertension, Department of Biostatistics, Mayo Clinic School of Medicine, Rochester, Minnesota 55905, USA
    Blood Press Monit 10:169-74. 2005
  8. ncbi request reprint A survey of validated automated home blood pressure monitors available for the Internet shopper
    John W Graves
    Division of Nephrology and Hypertension, Mayo Clinic School of Medicine and Mayo Foundation, Rochester, Minnesota 55905, USA
    Blood Press Monit 10:103-7. 2005
  9. doi request reprint Discarding the first of three nurse-auscultatory or oscillometric blood pressure measurements does not improve the association of office blood pressure with ABPM
    John W Graves
    Division of Nephrology and Hypertension, Mayo Clinic College of Medicine, Rochester, Minnesota 55905, USA
    Blood Press Monit 15:146-51. 2010
  10. ncbi request reprint When a "quality measure" may not be what it seems: the national committee for quality assurance report and hypertension control
    John W Graves
    Division of Nephrology and Hypertension, Mayo Clinic School of Medicine, 200 First Street SW, Rochester, MN 55905, USA
    J Clin Hypertens (Greenwich) 6:706-7. 2004

Collaborators

Detail Information

Publications23

  1. ncbi request reprint The Accoson Greenlight 300, the first non-automated mercury-free blood pressure measurement device to pass the International Protocol for blood pressure measuring devices in adults
    John W Graves
    Department of Internal Medicine, Mayo Clinic and Mayo Foundation, Rochester 55905, USA
    Blood Press Monit 9:13-7. 2004
    ..The Accoson Greenlight 300 device is the first non-automated mercury-free device for auscultatory blood pressure measurement to pass the International Protocol for validation of blood pressure measuring devices in adults...
  2. ncbi request reprint Prevalence of blood pressure cuff sizes in a referral practice of 430 consecutive adult hypertensives
    J W Graves
    Division of Hypertension, Mayo Clinic and Mayo Foundation, Rochester, Minnesota 55905, USA
    Blood Press Monit 6:17-20. 2001
    ..Vendors of blood pressure measurement devices should be aware of the changing demographics and the need for the large adult arm cuff to be routinely available...
  3. doi request reprint Diagnosis and management of chronic kidney disease
    John W Graves
    Division of Nephrology and Hypertension, Mayo Clinic, 200 First St SW, Rochester, MN 55905, USA
    Mayo Clin Proc 83:1064-9. 2008
    ..The nonspecialist should also be able to recognize the 9 therapies that are helpful in preservation of renal function in all patients with CKD...
  4. ncbi request reprint What is adequate hypertension control? Having your dinner and dessert too
    John W Graves
    Division of Nephrology and Hypertension, Mayo Clinic College of Medicine, Rochester, MN 55905, USA
    Cleve Clin J Med 74:748-54. 2007
    ..Controlling the blood pressure per se should be our primary concern ("dinner"), while choosing agents that may have added benefit in specific situations is secondary ("dessert")...
  5. ncbi request reprint The impact of observer and patient factors on the occurrence of digit preference for zero in blood pressure measurement in a hypertension specialty clinic: evidence for the need of continued observation
    John W Graves
    Division of Nephrology and Hypertension, Mayo Clinic College of Medicine and Mayo Foundation, 200 First Street SW, Rochester, MN 55905, USA
    Am J Hypertens 19:567-72. 2006
    ..This study analyzes the occurrence of zero preference in 52,827 blood pressure (BP) measurements in 8513 patients by 11 hypertension nurse specialists in the Hypertension Division at Mayo Clinic, Rochester, Minnesota...
  6. ncbi request reprint The trained observer better predicts daytime ABPM diastolic blood pressure in hypertensive patients than does an automated (Omron) device
    John W Graves
    Division of Nephrology and Hypertension, Mayo Clinic College of Medicine, Rochester, Minnesota 55905, USA
    Blood Press Monit 11:53-8. 2006
    ..This study compares blood pressures obtained by trained observers and with an oscillometric device (Omron 705CP) to 24-h ambulatory blood pressure monitoring...
  7. ncbi request reprint Limited (6-h) ambulatory blood pressure monitoring is a valid replacement for the office blood pressure by trained nurse clinician in the diagnosis of hypertension
    John W Graves
    Division of Nephrology and Hypertension, Department of Biostatistics, Mayo Clinic School of Medicine, Rochester, Minnesota 55905, USA
    Blood Press Monit 10:169-74. 2005
    ..To assess the ability of limited ambulatory blood pressure monitoring as a valid replacement for office blood pressure measurement done to American Heart Association criteria in diagnosing hypertension...
  8. ncbi request reprint A survey of validated automated home blood pressure monitors available for the Internet shopper
    John W Graves
    Division of Nephrology and Hypertension, Mayo Clinic School of Medicine and Mayo Foundation, Rochester, Minnesota 55905, USA
    Blood Press Monit 10:103-7. 2005
    ..Internet commerce increases dramatically each year. This study looked to identify the availability of validity of AHBPM and the correct cuff size to go with the AHBPM...
  9. doi request reprint Discarding the first of three nurse-auscultatory or oscillometric blood pressure measurements does not improve the association of office blood pressure with ABPM
    John W Graves
    Division of Nephrology and Hypertension, Mayo Clinic College of Medicine, Rochester, Minnesota 55905, USA
    Blood Press Monit 15:146-51. 2010
    ..We compare two methods of office BP measurement to determine whether discarding the first BP affects their association with ambulatory blood pressure monitoring (ABPM) readings...
  10. ncbi request reprint When a "quality measure" may not be what it seems: the national committee for quality assurance report and hypertension control
    John W Graves
    Division of Nephrology and Hypertension, Mayo Clinic School of Medicine, 200 First Street SW, Rochester, MN 55905, USA
    J Clin Hypertens (Greenwich) 6:706-7. 2004
  11. ncbi request reprint Does evidence-based medicine suggest that physicians should not be measuring blood pressure in the hypertensive patient?
    John W Graves
    Division of Hypertension, Mayo Clinic and Mayo Foundation, Rochester, Minnesota 55905, USA
    Am J Hypertens 17:354-60. 2004
    ....
  12. ncbi request reprint The changing distribution of arm circumferences in NHANES III and NHANES 2000 and its impact on the utility of the 'standard adult' blood pressure cuff
    John W Graves
    Division of Hypertension, Mayo Clinic and Mayo Foundation, Rochester, Minnesota 55905, USA
    Blood Press Monit 8:223-7. 2003
    ..Accurate blood pressure measurement is dependent on using a blood pressure cuff that is appropriate to the patient's arm circumference...
  13. ncbi request reprint Clinical decision-making in hypertension using an automated (BpTRU) measurement device
    J W Graves
    Mayo Clinic and Mayo Foundation, Rochester, MN 55905, USA
    J Hum Hypertens 17:823-7. 2003
    ..8280, 95% confidence interval, 0.721-0.9350). The oscillometric blood pressure measurement with the BpTRU is recommended as a replacement for poorly performed auscultatory blood pressure measurement in clinical practice...
  14. ncbi request reprint Martorell's hypertensive leg ulcer: case report and concise review of the literature
    J W Graves
    Division of Hypertension, Mayo Clinic and Mayo Foundation, 200 First Street SW, Rochester, MN 55905, USA
    J Hum Hypertens 15:279-83. 2001
    ..Hypertensive ischaemic leg ulcers will be more commonly recognised with a renewed appreciation of the existence of this clinical entity...
  15. pmc Novel use of Kaplan-Meier methods to explain age and gender differences in hypertension control rates
    Kent R Bailey
    Division of Biostatistics, Department of Health Sciences Research, Mayo Clinic College of Medicine, 200 First St SW, Rochester, MN 55905, USA
    Hypertension 51:841-7. 2008
    ....
  16. ncbi request reprint 65-year-old woman with painful leg ulcers
    Tywaun K Tillman
    Mayo Graduate School of Medicine, Mayo Clinic, Rochester, Minn 55905, USA
    Mayo Clin Proc 77:965-8. 2002
  17. ncbi request reprint The occurrence of the alerting response is independent of the method of blood pressure measurement in hypertensive patients
    Brandon R Grossardt
    Division of Biostatistics, Mayo Clinic College of Medicine, Rochester, MN 55905, USA
    Blood Press Monit 11:321-7. 2006
    ....
  18. ncbi request reprint Recommendations for blood pressure measurement in humans: an AHA scientific statement from the Council on High Blood Pressure Research Professional and Public Education Subcommittee
    Thomas G Pickering
    Columbia University College of Physicians and Surgeons, Behavioral Cardiovascular Health and Hypertension Program, 622 West 168th Street, PH9 946, New York, NY 10032, USA
    J Clin Hypertens (Greenwich) 7:102-9. 2005
  19. ncbi request reprint Reliability and validity of blood pressure measurement in the Secondary Prevention of Small Subcortical Strokes study
    Pablo E Pergola
    Department of Medicine, Division of Nephrology, University of Texas Health Science Center at San Antonio, San Antonio, TX 78229, USA
    Blood Press Monit 12:1-8. 2007
    ..Reliable and unbiased blood pressure measurement is critical to successful completion of the trial...
  20. ncbi request reprint Utility of ambulatory blood pressure monitoring in children and adolescents
    John W Graves
    Pediatr Nephrol 21:1640-52. 2006
    ....
  21. ncbi request reprint Distribution of 24-h ambulatory blood pressure in children: normalized reference values and role of body dimensions
    John W Graves
    J Hypertens 20:1939-40. 2002
  22. ncbi request reprint Hyponatremia in older women
    Ihab Hajjar
    Division of Geriatrics, University of South Carolina Palmetto Health Alliance, Columbia, SC, USA
    J Clin Hypertens (Greenwich) 6:37-9. 2004
  23. ncbi request reprint Blood pressure measurement in public places
    John W Graves
    Am Fam Physician 71:851-2. 2005