Research Topics
| Luiz BertelliSummaryAffiliation: Los Alamos National Laboratory Country: USA Publications
| Collaborators |
Detail Information
Publications
Internal dose assessment data management system for a large population of Pu workersL Bertelli
Los Alamos National Laboratory, MS G761, RP 2, Los Alamos, NM 87545, USA
Radiat Prot Dosimetry 127:347-9. 2007..The software also provides summary status and reports of the pending DAs, which are useful for managing the cases in process...
Three plutonium chelation cases at Los Alamos National LaboratoryLuiz Bertelli
RP 2, Health Physics Measurements, Radiation Protection, Mailstop G761, Los Alamos National Laboratory, Los Alamos, NM 87545, USA
Health Phys 99:532-8. 2010..An efficacy factor of about 50 was observed for a chelation treatment, which was administered at about 1.5 y after the incident, though the corresponding averted dose was very small (LA-UR 09-02934)...
Technical basis for using nose swab bioassay data for early internal dose assessmentRaymond A Guilmette
Los Alamos National Laboratory, MS G471, RP 2, Los Alamos, NM 87545, USA
Radiat Prot Dosimetry 127:356-60. 2007..However, this value is specific to the methods and models used at LANL, and should not be applied directly without considering possible differences in measurement and calculation methods...
Software for empirical building of biokinetic models for normal and decorporation-affected dataGuthrie Miller
Los Alamos National Laboratory, Albuquerque, NM 87108, USA
Health Phys 103:484-94. 2012..The radiation dose to the animal is also calculated using S quantities specific for the animal, although the tissue weighting factors used to calculate the effective dose are those for the human...
The NCRP wound model: development and applicationRaymond A Guilmette
Los Alamos National Laboratory, MS G761, RP 2, Los Alamos, NM 87545, USA
Radiat Prot Dosimetry 127:103-7. 2007..The latter application is needed for bioassay interpretation...
A study of early Los Alamos internal exposures to plutoniumG Miller
Los Alamos National Laboratory, MS M992, Los Alamos, NM 87545, USA
Radiat Prot Dosimetry 130:503-9. 2008..The urine bioassay data from this time period were not of high quality, and the more accurate intake prior tempers the effect of spurious high samples, which were probably caused by sample contamination...
Poisson mixture model for measurements using countingGuthrie Miller
Los Alamos National Laboratory, Los Alamos, NM, USA
Radiat Prot Dosimetry 138:363-75. 2010..The main purpose of this paper is to derive formulas for exact likelihood calculations in the case of various kinds of backgrounds...
Uncertainties in internal doses calculated for Mayak workers--a study of 63 casesG Miller
Los Alamos National Laboratory, Los Alamos, NM, USA
Radiat Prot Dosimetry 131:316-30. 2008..The main conclusion of the study is that these methods are now ready to be applied to the entire Mayak worker population...
IMPDOS (improved dosimetry and risk assessment for plutonium-induced diseases): internal dosimetry software tools developed for the Mayak worker studyG Miller
Los Alamos National Laboratory, Los Alamos, NM 87545, USA
Radiat Prot Dosimetry 131:308-15. 2008....
An empirical multivariate log-normal distribution representing uncertainty of biokinetic parameters for 137CsG Miller
Los Alamos National Laboratory, Los Alamos, NM, USA
Radiat Prot Dosimetry 131:198-211. 2008..The importance sampling method gives much smaller sampling uncertainty. No sampling method-dependent differences are perceptible for the uniform distribution methods...
Internal dosimetry verification and validation databaseG Miller
Los Alamos National Laboratory, Los Alamos, NM 87545, USA
Radiat Prot Dosimetry 127:361-9. 2007..A 'correct' result has been defined in two ways: (1) that the credible limits of the calculated dose include the correct dose and (2) that the calculated dose is within a factor of 2 of the correct dose...
Bayesian hypothesis testing-use in interpretation of measurementsG Miller
Los Alamos National Laboratory, MS E546, Los Alamos, NM 87545, USA
Health Phys 94:248-54. 2008..Real numerical examples are given and discussed, including the distribution of the non-null hypothesis probability over 4,000 internal dosimetry cases. Currently used comparable methods based on classical statistics are discussed...
Worldwide bioassay data resources for plutonium/americium internal dosimetry studiesG Miller
Los Alamos National Laboratory, HSR 12, Los Alamos, NM, USA
Radiat Prot Dosimetry 125:531-7. 2007..A case is made for a uniform standard for database format, and the XML standard is discussed...
Uranium dose assessment: a Bayesian approach to the problem of dietary backgroundTom Little
Los Alamos National Laboratory, MS G761, Los Alamos, NM 87545, USA
Radiat Prot Dosimetry 127:333-8. 2007..These methods, coupled with an algorithm for identifying each individual's baseline level of uranium from environmental sources, yield improved reliability in the identification of occupational intakes...
Comparison of dose estimation from occupational exposure to 239Pu using different modelling approachesS A Romanov
Southern Urals Biophysics Institute, Ozyorsk, Chelyabinsk Region, Russia
Radiat Prot Dosimetry 127:486-90. 2007..Thus, a careful validation of Pu lung dosimetry model is needed in Mayak worker dosimetry systems...
