Research Topics
| James TroppSummaryAffiliation: GE Healthcare Country: USA Publications
| Collaborators
|
Detail Information
Publications
Image brightening in samples of high dielectric constantJames Tropp
General Electric Medical Systems, 47697 Westinghouse Drive, Fremont, CA 94539, USA
J Magn Reson 167:12-24. 2004..An extended reciprocity formula for NMR reception, valid for an arbitrary electromagnetic Green's function, is also given in Appendix B...
Hyperpolarized 13C lactate, pyruvate, and alanine: noninvasive biomarkers for prostate cancer detection and gradingMark J Albers
Department of Bioengineering, University of California San Francisco, San Francisco, California 94158 2330, USA
Cancer Res 68:8607-15. 2008....
Multi-channel metabolic imaging, with SENSE reconstruction, of hyperpolarized [1-(13)C] pyruvate in a live rat at 3.0 tesla on a clinical MR scannerJames Tropp
GE Healthcare Technologies, Global Applied Sciences Lab, Fremont, CA, United States
J Magn Reson 208:171-7. 2011..The signal to noise ratio in was in some instances unexpectedly high in the parallel images; variability of the polarization among different trials, plus partial volume effects, are noted as a possible cause of this...
Radiation damping and reciprocity in nuclear magnetic resonance: the replacement of the filling factorJames Tropp
GE Healthcare Technologies, Global Applied Sciences Lab, Fremont, CA, USA
J Magn Reson 206:161-7. 2010..The predicted intrinsic linewidth, based upon three separate measurements of the efficiency, is 52.3 Hz, or 80% of the measured value...
Quantification of in vivo metabolic kinetics of hyperpolarized pyruvate in rat kidneys using dynamic 13C MRSITao Xu
Department of Electrical Engineering, Stanford University, Stanford, CA, USA
NMR Biomed 24:997-1005. 2011....
In vivo hyperpolarized 13C MR spectroscopic imaging with 1H decouplingAlbert P Chen
GE Healthcare, 11 Brunel Court, Suite 5116, Toronto, Ont, Canada M5V3Y3
J Magn Reson 197:100-6. 2009..Narrower linewidth for the [1-(13)C] lactate resonance was observed in hyperpolarized (13)C MRSI data in vivo with (1)H decoupling...
Three-frequency RF coil designed for optimized imaging of hyperpolarized, 13C-labeled compoundsIleana Hancu
GE Global Research Center, Niskayuna, New York, 12309, USA
Magn Reson Med 60:928-33. 2008..Images at the three resonant frequencies of this coil are presented from an exam involving hyperpolarized (13)C compounds in vivo...
Metabolic imaging in the anesthetized rat brain using hyperpolarized [1-13C] pyruvate and [1-13C] ethyl pyruvateRalph E Hurd
Global Applied Science Laboratory, GE Healthcare, Menlo Park, California 94025, USA
Magn Reson Med 63:1137-43. 2010..Hyperpolarized [1-(13)C]-ethyl pyruvate and [1-(13)C]-pyruvate metabolic imaging in normal brain is demonstrated and quantified in this feasibility and range-finding study...
Cerebral dynamics and metabolism of hyperpolarized [1-(13)C]pyruvate using time-resolved MR spectroscopic imagingRalph E Hurd
Global Applied Science Laboratory, GE Healthcare, Menlo Park, California 94025, USA
J Cereb Blood Flow Metab 30:1734-41. 2010..A model for brain [1-(13)C]lactate, based on blood-brain transport kinetics, CBV, and the observed pyruvate dynamics is described...
T(2) relaxation times of (13)C metabolites in a rat hepatocellular carcinoma model measured in vivo using (13)C-MRS of hyperpolarized [1-(13)C]pyruvateYi Fen Yen
Global Applied Science Laboratory, GE Healthcare, CA, USA
NMR Biomed 23:414-23. 2010..The study results show that the signal level and relaxivity of [1-(13)C]alanine may be promising biomarkers for HCC tumors. Its diagnostic values in HCC staging and treatment monitoring are yet to be explored...
Hyperpolarized C-13 spectroscopic imaging of the TRAMP mouse at 3T-initial experienceAlbert P Chen
Department of Radiology, University of California San Francisco, San Francisco, California, USA
Magn Reson Med 58:1099-106. 2007..135 cm(3) nominal spatial resolution. Elevated (13)C lactate (lac) was observed in both primary and metastatic tumors, demonstrating the feasibility of studying cellular bioenergetics in vivo with DNP hyperpolarized (13)C MRSI...
Assessment of the specific absorption rate and calibration of decoupling parameters for proton decoupled carbon-13 MR spectroscopy at 3.0 TMoyoko Saito
Biomedical Imaging Group, Photonics Research Institute, National Institute of Advanced Industrial Science and Technology, 1 8 31 Midorigaoka, Ikeda, Osaka 563 8577, Japan
Eur J Radiol 55:289-93. 2005..Then, the decoupling conditions of a glucose solution phantom were systematically optimized with combinations of decoupling bandwidth and power. The reliability of this procedure was discussed in conjunction with IEC guidelines...