Cine magnetic resonance microscopy of the rat heart using cardiorespiratory-synchronous projection reconstructionAnja C S Brau
Center for In Vivo Microscopy, Duke University Medical Center, Durham, NC 27710, USA
J Magn Reson Imaging 20:31-8. 2004..To tailor a cardiac magnetic resonance (MR) microscopy technique for the rat that combines improvements in pulse sequence design and physiologic control to acquire high-resolution images of cardiac structure and function...
Generalized self-navigated motion detection technique: Preliminary investigation in abdominal imagingAnja C S Brau
GE Healthcare, Applied Science Lab West, Menlo Park, California 94025, USA
Magn Reson Med 55:263-70. 2006..These preliminary results suggest that the self-navigated method is a promising technique for reducing motion artifacts in clinical abdominal and cardiac applications...
Multiecho reconstruction for simultaneous water-fat decomposition and T2* estimationHuanzhou Yu
Global Applied Science Lab, GE Healthcare, Menlo Park, California, USA
J Magn Reson Imaging 26:1153-61. 2007..The method removes interference of water-fat separation with iron-induced T2* effects and therefore has potential for the simultaneous characterization of hepatic steatosis (fatty infiltration) and iron overload...
Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methodsAnja C S Brau
Global Applied Science Lab, GE Healthcare, Menlo Park, CA 94025, USA
Magn Reson Med 59:382-95. 2008..This analysis may help guide the selection of PI methods for a given imaging task to achieve high reconstruction accuracy at minimal computational expense...
Effects of refocusing flip angle modulation and view ordering in 3D fast spin echoReed F Busse
GE Healthcare, MR Applied Science Lab, Madison, Wisconsin 53717, USA
Magn Reson Med 60:640-9. 2008....
Fiber-optic stethoscope: a cardiac monitoring and gating system for magnetic resonance microscopyAnja C S Brau
Center for In Vivo Microscopy, Duke University Medical Center, Durham, North Carolina 27710, USA
Magn Reson Med 47:314-21. 2002..The optical system is shown to provide a robust cardiac monitoring and gating signal in rats and mice during routine cardiac MR microscopy...
Measurement of regional lung function in rats using hyperpolarized 3helium dynamic MRIBen T Chen
Center for In Vivo Microscopy, Duke University Medical Center, Durham, North Carolina 27710, USA
Magn Reson Med 49:78-88. 2003..This work provides a novel approach to simultaneously assess dynamic regional function and morphology...
Single acquisition water-fat separation: feasibility study for dynamic imagingHuanzhou Yu
Global Applied Science Laboratory, GE Healthcare, Menlo Park, CA, USA
Magn Reson Med 55:413-22. 2006..In this situation, the calibration scans required by both methods can be integrated into a shared calibration scan. Promising results were obtained in breast, abdominal, and cardiac imaging applications...