Optimization of combined electron and photon beams for breast cancerW Xiong
Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
Phys Med Biol 49:1973-89. 2004..It is concluded that combined photon and electron beam therapy may be advantageous for treating breast cancer compared to conventional treatment techniques using tangential wedged photon beams followed by a boost electron field...
Effect of patient variation on standard- and hypo-fractionated radiotherapy of prostate cancerW Xiong
Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
Phys Med Biol 50:1483-92. 2005..On the other hand, for lower alpha/beta ratios, the beta term also plays a more important role in cell-killing and therefore the patient variation parameter sigmabeta must be considered when designing a new dose fractionation scheme...
Dosimetric verification of IMRT treatment planning using Monte Carlo simulations for prostate cancerJ Yang
Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
Phys Med Biol 50:869-78. 2005..These results suggest that heterogeneity correction should be used in dose calculation for prostate cancer with non-coplanar beam arrangements...
A practical Monte Carlo MU verification tool for IMRT quality assuranceJ Fan
Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
Phys Med Biol 51:2503-15. 2006..The results between the point detector and MCSIM agreed to within 2%. A factor of 20 speedup can be achieved with the point detector method compared with direct Monte Carlo simulations...
Modelling of electron contamination in clinical photon beams for Monte Carlo dose calculationJ Yang
Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 191 11, USA
Phys Med Biol 49:2657-73. 2004..The Monte Carlo calculated dose distributions were compared with measured data. Our results showed good agreement (less than 2% or 2 mm) for 6, 10 and 18 MV photon beams...
Effect of statistical uncertainties on Monte Carlo treatment planningC M Ma
Radiation Oncology Department, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
Phys Med Biol 50:891-907. 2005..We provide practical guidelines for the clinical implementation of Monte Carlo treatment planning and show realistic examples of Monte Carlo based IMRT and MERT plans...
Clinical implementation of intensity-modulated tangential beam irradiation for breast cancerJ S Li
Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111, USA
Med Phys 31:1023-31. 2004..The IMRT technique has been proven practical for breast treatment clinically. The results showed that tangential IMRT improved the dose homogeneity in the breast and reduced the dose to the lung and heart...
Characterization of megavoltage electron beams delivered through a photon multi-leaf collimator (pMLC)F C P du Plessis
Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
Phys Med Biol 51:2113-29. 2006..Bremsstrahlung measurements taken at 60 cm SSD for a 9 x 9 cm2 field as shaped by the pMLC compared within 1% to bremsstrahlung measurements taken at 100 cm SSD for a 10 x 10 cm2 electron applicator field at 100 cm SSD...
Intensity modulated radiation therapy using laser-accelerated protons: a Monte Carlo dosimetric studyE Fourkal
Radiation Oncology Department, Fox Chase Cancer Center, 7701 Borehole Avenue, Philadelphia 19111, USA
Phys Med Biol 48:3977-4000. 2003..It is shown that for a two-beam arrangement (parallel-opposed) it is possible to achieve both superior target coverage with 5% dose inhomogeneity within the target and excellent sparing of surrounding tissue...
Tip-enhanced near-field Raman spectroscopy with a scanning tunneling microscope and side-illumination opticsK J Yi
Department of Electrical Engineering, University of Nebraska Lincoln, Lincoln, Nebraska 68588 0511, USA
Rev Sci Instrum 79:073706. 2008..Furthermore, the developed instrument features fast and reliable optical alignment, versatile sample adaptability, and effective suppression of far-field signals...