Lili Chen

Summary

Affiliation: Fox Chase Cancer Center
Country: USA

Publications

  1. ncbi Dosimetric evaluation of MRI-based treatment planning for prostate cancer
    L Chen
    Radiation Oncology Department, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
    Phys Med Biol 49:5157-70. 2004
  2. ncbi MR-guided focused ultrasound: enhancement of intratumoral uptake of [³H]-docetaxel in vivo
    Lili Chen
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
    Phys Med Biol 55:7399-410. 2010
  3. ncbi Magnetic resonance-based treatment planning for prostate intensity-modulated radiotherapy: creation of digitally reconstructed radiographs
    Lili Chen
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
    Int J Radiat Oncol Biol Phys 68:903-11. 2007
  4. ncbi Rectal dose variation during the course of image-guided radiation therapy of prostate cancer
    Lili Chen
    Radiation Oncology Department, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
    Radiother Oncol 95:198-202. 2010
  5. ncbi Commissioning and quality assurance of a commercial stereotactic treatment-planning system for extracranial IMRT
    Lu Wang
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111, USA
    J Appl Clin Med Phys 7:21-34. 2006
  6. ncbi Monte Carlo based IMRT dose verification using MLC log files and R/V outputs
    Wei Luo
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111, USA
    Med Phys 33:2557-64. 2006
  7. ncbi MRI-based treatment planning for radiotherapy: dosimetric verification for prostate IMRT
    Lili Chen
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, USA
    Int J Radiat Oncol Biol Phys 60:636-47. 2004
  8. ncbi Benefit of three-dimensional image-guided stereotactic localization in the hypofractionated treatment of lung cancer
    Lu Wang
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
    Int J Radiat Oncol Biol Phys 66:738-47. 2006
  9. ncbi Dosimetric advantage and clinical implication of a micro-multileaf collimator in the treatment of prostate with intensity-modulated radiotherapy
    Lu Wang
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
    Med Dosim 30:97-103. 2005
  10. ncbi Quantitative study of focused ultrasound enhanced doxorubicin delivery to prostate tumor in vivo with MRI guidance
    Xiaoming Chen
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
    Med Phys 39:2780-6. 2012

Detail Information

Publications16

  1. ncbi Dosimetric evaluation of MRI-based treatment planning for prostate cancer
    L Chen
    Radiation Oncology Department, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
    Phys Med Biol 49:5157-70. 2004
    ..The difference in the target dose between CT- and MRI-based plans using homogeneous geometry was within 2.5%. Our results suggest that MRI-based treatment planning is suitable for radiotherapy of prostate cancer...
  2. ncbi MR-guided focused ultrasound: enhancement of intratumoral uptake of [³H]-docetaxel in vivo
    Lili Chen
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
    Phys Med Biol 55:7399-410. 2010
    ..Our data showed increased (³H-docetaxel concentration in the tumor in the MRgFUS-treated group (1079 ± 132 cmp/75 mg) versus those without MRgFUS treatment (524 ± 201 cmp/75 mg) with P = 0.037...
  3. ncbi Magnetic resonance-based treatment planning for prostate intensity-modulated radiotherapy: creation of digitally reconstructed radiographs
    Lili Chen
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
    Int J Radiat Oncol Biol Phys 68:903-11. 2007
    ....
  4. ncbi Rectal dose variation during the course of image-guided radiation therapy of prostate cancer
    Lili Chen
    Radiation Oncology Department, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
    Radiother Oncol 95:198-202. 2010
    ..To investigate the change in rectal dose during the treatment course for intensity-modulated radiotherapy (IMRT) of prostate cancer with image-guidance...
  5. ncbi Commissioning and quality assurance of a commercial stereotactic treatment-planning system for extracranial IMRT
    Lu Wang
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111, USA
    J Appl Clin Med Phys 7:21-34. 2006
    ..However, the plans calculated by both methods met our clinical criteria. We conclude that the accuracy of the XKnifetrade mark RT2 treatment-planning system is adequate for the clinical implementation of stereotactic IMRT...
  6. ncbi Monte Carlo based IMRT dose verification using MLC log files and R/V outputs
    Wei Luo
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111, USA
    Med Phys 33:2557-64. 2006
    ..2 mm can result in a target dose error of about 1.0%...
  7. ncbi MRI-based treatment planning for radiotherapy: dosimetric verification for prostate IMRT
    Lili Chen
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, USA
    Int J Radiat Oncol Biol Phys 60:636-47. 2004
    ....
  8. ncbi Benefit of three-dimensional image-guided stereotactic localization in the hypofractionated treatment of lung cancer
    Lu Wang
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
    Int J Radiat Oncol Biol Phys 66:738-47. 2006
    ..The aim of this study was to investigate the benefit of image-guided stereotactic localization in the hypofractionated treatment for medically inoperable non-small-cell lung cancer...
  9. ncbi Dosimetric advantage and clinical implication of a micro-multileaf collimator in the treatment of prostate with intensity-modulated radiotherapy
    Lu Wang
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
    Med Dosim 30:97-103. 2005
    ..When used for conventional fractionation scheme, mMLC for IMRT of the prostate may reduce the toxicity to the critical organs...
  10. ncbi Quantitative study of focused ultrasound enhanced doxorubicin delivery to prostate tumor in vivo with MRI guidance
    Xiaoming Chen
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA 19111, USA
    Med Phys 39:2780-6. 2012
    ..The purpose of this study was to investigate the potential of MR-guided pulsed focused ultrasound (pFUS) for the enhancement of drug uptake in prostate tumors in vivo using doxorubicin (Dox)...
  11. ncbi MR-guided pulsed high intensity focused ultrasound enhancement of docetaxel combined with radiotherapy for prostate cancer treatment
    Zhaomei Mu
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, USA
    Phys Med Biol 57:535-45. 2012
    ....
  12. ncbi Effect of collimator and couch angle change on breast IMRT dose distributions
    Jie Yang
    Department of Radiation Oncology, Penn State Cancer Institute, Hershey, PA 17033, USA
    J Appl Clin Med Phys 10:3058. 2009
    ..Our results show that a 4-degree change in the collimator angle or the couch angle did not affect the dose distribution significantly and it is acceptable in the clinic for patient treatment...
  13. ncbi Uncertainties in IMRT dosimetry
    Jin sheng Li
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111, USA
    Med Phys 37:2491-500. 2010
    ..These characteristics include the accelerator source distribution and multileaf collimator (MLC) geometry...
  14. ncbi Stereotactic IMRT for prostate cancer: setup accuracy of a new stereotactic body localization system
    Lu Wang
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111, USA
    J Appl Clin Med Phys 5:18-28. 2004
    ..A rigid frame system serves as a reliable alignment reference in terms of repositioning patients into the planning position, while skin-based reference showed larger deviations in repositioning patients...
  15. ncbi Target repositional accuracy and PTV margin verification using three-dimensional cone-beam computed tomography (CBCT) in stereotactic body radiotherapy (SBRT) of lung cancers
    Lu Wang
    Fox Chase Cancer Center, Philadelphia, PA 19111, USA
    J Appl Clin Med Phys 13:3708. 2012
    ..This demonstrated that the PTV margin that is designed on the MIP image-based ITV was adequate for lung SBRT...
  16. ncbi Effect of gold marker seeds on magnetic resonance spectroscopy of the prostate
    Murshed Hossain
    Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, USA
    Int J Radiat Oncol Biol Phys 83:451-8. 2012
    ..The purpose of this study was to quantify the effects of gold seeds on the quality of MRSI data acquired in phantom experiments...