Research Topics
| Jenny K HoangSummaryAffiliation: Duke University Medical Center Country: USA Publications
| Collaborators
|
Detail Information
Publications
Can mammographic findings help discriminate between atypical ductal hyperplasia and ductal carcinoma in situ after needle core biopsy?Jenny K Hoang
St Vincent s Breastscreen, St Vincent s Hospital, University of Melbourne, Melbourne, Australia
Breast 17:282-8. 2008..In conclusion, detailed assessment of calcification distribution and form gave helpful predictors for malignancy. Lesions with fine rounded calcification were always benign...
MDCT angiography after open thoracic aortic surgery: pearls and pitfallsJenny K Hoang
Department of Radiology, Division of Cardiothoracic Imaging, Duke University Medical Center, Box 3808, Erwin Rd, Durham, NC 27710, USA
AJR Am J Roentgenol 192:W20-7. 2009..CONCLUSION: An understanding of surgical thoracic aortic procedures will allow appropriate differentiation of normal from abnormal CTA findings on postoperative imaging...
MDCT angiography of thoracic aorta endovascular stent-grafts: pearls and pitfallsJenny K Hoang
Department of Radiology, Division of Cardiothoracic Imaging, Duke University Medical Center, Durham, NC 27710, USA
AJR Am J Roentgenol 192:515-24. 2009..CONCLUSION: Luminal and extraluminal changes to the thoracic aorta occur after endovascular stent-grafting. The radiologist can facilitate appropriate management by detecting and differentiating expected CTA findings from complications...
Multiplanar CT and MRI of collections in the retropharyngeal space: is it an abscess?Jenny K Hoang
Department of Radiology, Division of Neuroradiology, Duke University Medical Center, Box 3808, Erwin Rd, Durham, NC 27710, USA
AJR Am J Roentgenol 196:W426-32. 2011..In this pictorial essay, we describe the anatomy of the retropharyngeal space and offer a four-step approach to evaluating retropharyngeal collections on multiplanar imaging...
Organ-based dose current modulation and thyroid shields: techniques of radiation dose reduction for neck CTJenny K Hoang
Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA
AJR Am J Roentgenol 198:1132-8. 2012....
Radiation dose exposure for lumbar spine epidural steroid injections: a comparison of conventional fluoroscopy data and CT fluoroscopy techniquesJenny K Hoang
Department of Radiology, Duke University Medical Center, Box 3808, Erwin Rd, Durham, NC 27710, USA
AJR Am J Roentgenol 197:778-82. 2011..The purpose of this article is to compare the radiation dose of conventional fluoroscopy-guided lumbar epidural steroid injections (ESIs) and CT fluoroscopy (CTF)-guided lumbar ESI using both clinical data and anthropomorphic phantoms...
Variation in tube voltage for adult neck MDCT: effect on radiation dose and image qualityJenny K Hoang
Department of Radiology, Duke University Medical Center, Box 3808, Erwin Rd, Durham, NC 27710, USA
AJR Am J Roentgenol 198:621-7. 2012..The purpose of this study was to assess the effect of peak kilovoltage on radiation dose and image quality in adult neck MDCT...
Analysis of pretreatment FDG-PET SUV parameters in head-and-neck cancer: tumor SUVmean has superior prognostic valueKristin A Higgins
Department of Radiation Oncology, Duke University Medical Center, Durham, NC 27710, USA
Int J Radiat Oncol Biol Phys 82:548-53. 2012..To evaluate the prognostic significance of different descriptive parameters in head-and-neck cancer patients undergoing pretreatment [F-18] fluoro-D-glucose-positron emission tomography (FDG-PET) imaging...
Correlation of cross-sectional diameter with image quality and radiation exposure in MDCT examinations of the neckJenny K Hoang
Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA
AJR Am J Roentgenol 197:W904-9. 2011..The purpose of this study was to identify an optimal cross-sectional neck diameter that correlates with image quality and radiation exposure in MDCT examinations of the neck performed with automatic tube current modulation...
Evaluation of cervical lymph nodes in head and neck cancer with CT and MRI: tips, traps, and a systematic approachJenny K Hoang
Department of Radiology, Duke University Medical Center, Box 3808, Erwin Rd, Durham, NC 27710, USA
AJR Am J Roentgenol 200:W17-25. 2013..CONCLUSION: The presence and extent of nodal metastases in head and neck cancer has a great impact on treatment and prognosis. Pretreatment CT and MRI of the neck are commonly performed to evaluate for nodal metastases...
CT mucosal window settings: a novel approach to evaluating early T-stage head and neck carcinomaJenny K Hoang
Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA
AJR Am J Roentgenol 195:1002-6. 2010....
Multiplanar sinus CT: a systematic approach to imaging before functional endoscopic sinus surgeryJenny K Hoang
Department of Radiology, Division of Neuroradiology, Duke University Medical Center, Durham NC, 27710, USA
AJR Am J Roentgenol 194:W527-36. 2010..Each imaging plane is valuable for displaying anatomic variants, which can predispose a patient to recurrent disease and affect the surgical approach, and critical variants, which can make surgery hazardous...
CT fluoroscopy-assisted cervical transforaminal steroid injection: tips, traps, and use of contrast materialJenny K Hoang
Department of Radiology, Division of Neuroradiology, Duke University Medical Center, Durham, NC 27710, USA
AJR Am J Roentgenol 195:888-94. 2010..Use of contrast material for CT fluoroscopic guidance facilitates appropriate needle positioning and reduces the risk of complications...
Radiation dose for routine clinical adult brain CT: Variability on different scanners at one institutionTracy A Jaffe
Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA
AJR Am J Roentgenol 195:433-8. 2010..The purpose of this study was to determine, using an anthropomorphic phantom, whether patients are subject to variable radiation doses based on scanner assignment for routine CT of the brain...
Optimization of tube current in coronary multidetector computed tomography angiography: assessment of a standardized method to individualize current selection based on body habitusJenny K Hoang
Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA
J Comput Assist Tomogr 33:498-504. 2009....
Ascending thoracic aorta: postoperative imaging evaluationJulia A Prescott-Focht
Department of Radiology, Sanford USD Medical Center, Sioux Falls, SD, USA
Radiographics 33:73-85. 2013..Radiologists must be familiar with these procedures and their imaging features to identify normal postoperative appearances and complications...
FDG-PET assessment of the effect of head and neck radiotherapy on parotid gland glucose metabolismMichael C Roach
School of Medicine, Duke University Medical Center, Duke University, Durham, NC 27710, USA
Int J Radiat Oncol Biol Phys 82:321-6. 2012..The goal of this retrospective study was to identify the radiation dose-response relationship of parotid gland glucose metabolism in patients with head and neck squamous cell carcinoma (HNSCC)...
What to do with incidental thyroid nodules on imaging? An approach for the radiologistJenny K Hoang
Division of Neuroradiology, Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA
Semin Ultrasound CT MR 33:150-7. 2012..This article describes the problem of the incidental thyroid nodule, reviews the imaging findings of malignancy, and discusses an approach to reporting the incidental thyroid nodule...
Early changes in tumor size in patients treated for advanced stage nonsmall cell lung cancer do not correlate with survivalKatherine R Birchard
Department of Radiology, University of North Carolina Hospital, Chapel Hill, North Carolina, USA
Cancer 115:581-6. 2009....
US Features of thyroid malignancy: pearls and pitfallsJenny K Hoang
Department of Medical Imaging, St Vincent s Hospital Melbourne, University of Melbourne, 41 Victoria Parade, Fitzroy 3065, Victoria, Australia
Radiographics 27:847-60; discussion 861-5. 2007....
