I H Lieberman

Summary

Affiliation: Cleveland Clinic Foundation
Country: USA

Publications

  1. ncbi request reprint Histologic evaluation of human vertebral bodies after vertebral augmentation with polymethyl methacrylate
    Daisuke Togawa
    Department of Orthopaedic Surgery, The Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA
    Spine (Phila Pa 1976) 28:1521-7. 2003
  2. ncbi request reprint Vertebroplasty and kyphoplasty: filler materials
    Isador H Lieberman
    Cleveland Clinic Spine Institute, The Cleveland Clinic Foundation, 9500 Euclid Avenue, OH 44195, USA
    Spine J 5:305S-316S. 2005
  3. ncbi request reprint Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: Part I--Technical development and a test case result
    Isador H Lieberman
    Cleveland Clinic Spine Institute, Minimally Invasive Surgery Center, Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA
    Neurosurgery 59:641-50; discussion 641-50. 2006
  4. ncbi request reprint Three-dimensional computed tomographic volume rendering techniques in endoscopic thoracoplasty
    I H Lieberman
    Department of Orthopedic Surgery and Radiology, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH 44195, USA
    Spine J 1:390-4. 2001
  5. ncbi request reprint Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures
    I H Lieberman
    Department of Orthopaedics, Cleveland Clinic Foundation, Cleveland, Ohio, USA
    Spine (Phila Pa 1976) 26:1631-8. 2001
  6. ncbi request reprint Vertebral augmentation and the limits of interpreting complications reported in the food and drug administration manufacturer and user facility device experience database
    Isador H Lieberman
    Department of Orthopaedic Surgery, The Cleveland Clinic Foundation, Cleveland, OH 44195, USA
    J Vasc Interv Radiol 15:1193-6. 2004
  7. ncbi request reprint Transperitoneal laparoscopic exposure for lumbar interbody fusion
    I H Lieberman
    Cleveland Clinic Foundation, Ohio, USA
    Spine (Phila Pa 1976) 25:509-14; discussion 515. 2000
  8. ncbi request reprint Functional outcomes of kyphoplasty for the treatment of osteoporotic and osteolytic vertebral compression fractures
    A J Khanna
    Cleveland Clinic Spine Institute and Minimally Invasive Surgery Center, Cleveland Clinic Foundation, Cleveland, OH, USA
    Osteoporos Int 17:817-26. 2006
  9. ncbi request reprint Kyphoplasty in the treatment of osteolytic vertebral compression fractures as a result of multiple myeloma
    S Dudeney
    Department of Orthopaedics and Minimally Invasive Surgery Center, Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA
    J Clin Oncol 20:2382-7. 2002
  10. ncbi request reprint Prone position endoscopic transthoracic release with simultaneous posterior instrumentation for spinal deformity: a description of the technique
    I H Lieberman
    Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA
    Spine (Phila Pa 1976) 25:2251-7. 2000

Collaborators

Detail Information

Publications37

  1. ncbi request reprint Histologic evaluation of human vertebral bodies after vertebral augmentation with polymethyl methacrylate
    Daisuke Togawa
    Department of Orthopaedic Surgery, The Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA
    Spine (Phila Pa 1976) 28:1521-7. 2003
    ..Histologic documentation of vertebral bodies retrieved from human patients...
  2. ncbi request reprint Vertebroplasty and kyphoplasty: filler materials
    Isador H Lieberman
    Cleveland Clinic Spine Institute, The Cleveland Clinic Foundation, 9500 Euclid Avenue, OH 44195, USA
    Spine J 5:305S-316S. 2005
    ..In this review paper, we will focus on the issues and characteristics of these filler materials as they pertain to vertebral augmentation procedures...
  3. ncbi request reprint Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: Part I--Technical development and a test case result
    Isador H Lieberman
    Cleveland Clinic Spine Institute, Minimally Invasive Surgery Center, Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA
    Neurosurgery 59:641-50; discussion 641-50. 2006
    ..To introduce a new miniature robot (SpineAssist; MAZOR Surgical Technologies, Caesarea, Israel) that has been developed and tested as a surgical assistant for accurate percutaneous placement of pedicle screws and translaminar facet screws...
  4. ncbi request reprint Three-dimensional computed tomographic volume rendering techniques in endoscopic thoracoplasty
    I H Lieberman
    Department of Orthopedic Surgery and Radiology, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH 44195, USA
    Spine J 1:390-4. 2001
    ....
  5. ncbi request reprint Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures
    I H Lieberman
    Department of Orthopaedics, Cleveland Clinic Foundation, Cleveland, Ohio, USA
    Spine (Phila Pa 1976) 26:1631-8. 2001
    ..An Institutional Review Board-approved Phase I efficacy study of inflatable bone tamp usage in the treatment of symptomatic osteoporotic compression fractures...
  6. ncbi request reprint Vertebral augmentation and the limits of interpreting complications reported in the food and drug administration manufacturer and user facility device experience database
    Isador H Lieberman
    Department of Orthopaedic Surgery, The Cleveland Clinic Foundation, Cleveland, OH 44195, USA
    J Vasc Interv Radiol 15:1193-6. 2004
  7. ncbi request reprint Transperitoneal laparoscopic exposure for lumbar interbody fusion
    I H Lieberman
    Cleveland Clinic Foundation, Ohio, USA
    Spine (Phila Pa 1976) 25:509-14; discussion 515. 2000
    ..A prospective clinical trial of the transperitoneal laparoscopic approach to the lumbar spine in a consecutive series of patients undergoing anterior lumbar interbody fusion...
  8. ncbi request reprint Functional outcomes of kyphoplasty for the treatment of osteoporotic and osteolytic vertebral compression fractures
    A J Khanna
    Cleveland Clinic Spine Institute and Minimally Invasive Surgery Center, Cleveland Clinic Foundation, Cleveland, OH, USA
    Osteoporos Int 17:817-26. 2006
    ..Our secondary purpose was to compare such functional outcomes in patients with osteoporosis versus multiple myeloma...
  9. ncbi request reprint Kyphoplasty in the treatment of osteolytic vertebral compression fractures as a result of multiple myeloma
    S Dudeney
    Department of Orthopaedics and Minimally Invasive Surgery Center, Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA
    J Clin Oncol 20:2382-7. 2002
    ..The purpose of the IBT is to restore the vertebral body back toward its original height, while creating a cavity that can be filled with highly viscous bone cement...
  10. ncbi request reprint Prone position endoscopic transthoracic release with simultaneous posterior instrumentation for spinal deformity: a description of the technique
    I H Lieberman
    Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA
    Spine (Phila Pa 1976) 25:2251-7. 2000
    ..This simultaneous technique can be extended for use in correction of a variety of thoracic spinal pathologies...
  11. ncbi request reprint Re: Verlaan JJ, Van Helden WH, Oner FC, et al. Balloon vertebroplasty with calcium phosphate cement for direct restoration of traumatic thoraco-lumbar vertebral fractures. Spine 2002;27:543-548
    Isador H Lieberman
    Spine (Phila Pa 1976) 27:2300-1; author reply 2300-1. 2002
  12. ncbi request reprint Anterior vertebral body screw pullout testing. A comparison of Zeilke, Kaneda, Universal Spine System, and Universal Spine System with pullout-resistant nut
    I H Lieberman
    Division of Orthopaedics, Cleveland Clinic Foundation, Ohio, USA
    Spine (Phila Pa 1976) 23:908-10. 1998
    ..The addition of a pullout-resistant nut may be applicable to multilevel implant constructs to prevent screw pullout at the top and bottom...
  13. ncbi request reprint Endoscopic approaches to metastatic thoracic disease
    R F McLain
    Section of Spine Surgery, Department of Orthopaedic Surgery, The Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA
    Spine (Phila Pa 1976) 25:1855-8. 2000
    ..The two authors weigh the relative advantages and disadvantages of these approaches for the selected patient with metastatic thoracic disease...
  14. ncbi request reprint Biomechanical changes after the augmentation of experimental osteoporotic vertebral compression fractures in the cadaveric thoracic spine
    Mark M Kayanja
    Department of Orthopaedics, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH 44195, USA
    Spine J 5:55-63. 2005
    ..However, if alignment is improved or restored, there will be less risk of adjacent failure...
  15. doi request reprint Radiation exposure to the surgeon and the patient during kyphoplasty
    Thomas E Mroz
    Spine Institute, Cleveland Clinic Foundation, Cleveland, OH, USA
    J Spinal Disord Tech 21:96-100. 2008
    ..Prospective study of patients who underwent single or multilevel kyphoplasty for vertebral fractures...
  16. doi request reprint The use of allograft bone in spine surgery: is it safe?
    Thomas E Mroz
    Neuroscience Institute, Center for Spine Health, Cleveland Clinic, Cleveland, OH 44195, USA
    Spine J 9:303-8. 2009
    ..An analysis of allograft recall and its safety in spinal surgery has not been reported previously...
  17. ncbi request reprint The mechanics of polymethylmethacrylate augmentation
    Mark Kayanja
    Department of Orthopaedic Surgery A41, Cleveland Clinic Foundation, Cleveland OH 44195, USA
    Clin Orthop Relat Res 443:124-30. 2006
    ....
  18. ncbi request reprint Radiographic and histologic findings of vertebral augmentation using polymethylmethacrylate in the primate spine: percutaneous vertebroplasty versus kyphoplasty
    Daisuke Togawa
    Cleveland Clinic Spine Institute, Cleveland, OH 44195, USA
    Spine (Phila Pa 1976) 31:E4-10. 2006
    ..Animal study...
  19. ncbi request reprint Kyphoplasty for vertebral compression fractures: 1-year clinical outcomes from a prospective study
    Jean Valery C E Coumans
    Department of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02118, USA
    J Neurosurg 99:44-50. 2003
    ..Recently, kyphoplasty was developed in an effort to circumvent this problem. Although its immediate results have been reported, it is unclear whether the benefits endure...
  20. ncbi request reprint Minimally invasive treatments of osteoporotic vertebral compression fractures: vertebroplasty and kyphoplasty
    Frank M Phillips
    University of Chicago Spine Center, Chicago, Illinois, USA
    Instr Course Lect 52:559-67. 2003
    ..Kyphoplasty allows for low-pressure cement injection and affords the opportunity to correct spinal deformity. Further study is required to define the precise indications, timing, and relative merits of these techniques...
  21. pmc Occipito-cervical fusion using posterior titanium plates
    I H Lieberman
    Department of Orthopaedics, The Cleveland Clinic Foundation, OH 44195, USA
    Eur Spine J 7:308-12. 1998
    ..There were no instances of plate breakage. We conclude that titanium plate fixation of the occipito-cervical junction is versatile and stable. The plates maintain axial correction and allow for future MR imaging...
  22. ncbi request reprint Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: part 2--Evaluation of system accuracy
    Daisuke Togawa
    Cleveland Clinic Spine Institute, Minimally Invasive Surgery Center, The Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA
    Neurosurgery 60:ONS129-39; discussion ONS139. 2007
    ..To evaluate the accuracy of a novel bone-mounted miniature robotic system for percutaneous placement of pedicle and translaminar facet screws...
  23. ncbi request reprint Musculoskeletal allograft risks and recalls in the United States
    Thomas E Mroz
    Neuroscience Institute, Center for Spine Health, The Cleveland Clinic, OH 44195, USA
    J Am Acad Orthop Surg 16:559-65. 2008
    ..Infectious disease transmission following allograft implantation may occur if potential donors are not adequately evaluated or screened serologically during the prerecovery phase and if the implant is not sterilized before implantation...
  24. ncbi request reprint Histological evaluation of biopsies obtained from vertebral compression fractures: unsuspected myeloma and osteomalacia
    Daisuke Togawa
    Cleveland Clinic Spine Institute, Department of Orthopaedic Surgery, The Cleveland Clinic Foundation, Cleveland, OH 44195, USA
    Spine (Phila Pa 1976) 30:781-6. 2005
    ..A histological evaluation of biopsies obtained from presumed osteoporotic vertebral compression fractures (VCF) to confirm possible osteomalacia after tetracycline labeling...
  25. doi request reprint Vertebral augmentation in osteoporotic and osteolytic fractures
    Krzysztof Siemionow
    Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio, USA
    Curr Opin Support Palliat Care 3:219-25. 2009
    ..To discuss recent advances in percutaneous minimally invasive vertebral augmentation techniques used in the treatment of osteolytic and osteoporotic compression fractures...
  26. ncbi request reprint Vertebroplasty and kyphoplasty affect vertebral motion segment stiffness and stress distributions: a microstructural finite-element study
    Tony S Keller
    Department of Mechanical Engineering, University of Vermont, Burlington 05405 0156, USA
    Spine (Phila Pa 1976) 30:1258-65. 2005
    ..The mechanical behavior of a thoracic motion segment following cement augmentation was studied using the finite-element method...
  27. ncbi request reprint Vertebroplasty and kyphoplasty for the management of osteoporotic vertebral compression fractures
    Dhruv B Pateder
    Steadman Hawkins Clinic, Vail, CO 81657, USA
    Orthop Clin North Am 38:409-18; abstract vii. 2007
    ..The authors discuss the procedural steps, advantages and disadvantages, and results of each technique, recognizing that prospective, randomized controlled studies are necessary to objectively compare the two techniques...
  28. ncbi request reprint Lumbar intervertebral body fusion cages: histological evaluation of clinically failed cages retrieved from humans
    Daisuke Togawa
    Department of Orthopaedic Surgery, The Cleveland Clinic Foundation, Cleveland, OH 44195, USA
    J Bone Joint Surg Am 86:70-9. 2004
    ..The purpose of this study was to describe the contents of retrieved, clinically failed, interbody cages from human patients, with special reference to the influence of graft type on the viability of bone in the cages...
  29. ncbi request reprint In vitro stability of FRA spacers with integrated crossed screws for anterior lumbar interbody fusion
    Ranjith R Kuzhupilly
    Department of Spine Surgery, Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA
    Spine (Phila Pa 1976) 27:923-8. 2002
    ..Mechanical testing of human lumbar functional spine units was carried out after instrumenting the disc space with femoral ring allografts (FRAs) with and without integrated crossed anterior screws applied into the adjacent bodies...
  30. ncbi request reprint Vertebral augmentation in osteoporosis and bone metastasis
    Krzysztof Siemionow
    Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, Ohio 44195, USA
    Curr Opin Support Palliat Care 1:323-7. 2007
    ..The purpose of this review is to discuss recent advances in percutaneous minimally invasive vertebral augmentation techniques used in the treatment of compression fractures...
  31. ncbi request reprint Distribution of anterior cortical shear strain after a thoracic wedge compression fracture
    Mark M Kayanja
    Spine Research Laboratory, Department of Orthopaedics, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH 44195, USA
    Spine J 4:76-87. 2004
    ..The strain distribution along the anterior cortex, the major load-bearing pathway in flexion, may be predictive of impending VCF. Regions of high strain distribution are likely to experience secondary fracture...
  32. ncbi request reprint Cement emboli in vertebroplasty and kyphoplasty
    Daisuke Togawa
    AJR Am J Roentgenol 185:277; author reply 277. 2005
  33. ncbi request reprint Histology of tissues within retrieved human titanium mesh cages
    Daisuke Togawa
    Department of Anatomic Pathology, Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA
    Spine (Phila Pa 1976) 28:246-53; discussion 254. 2003
    ..Histologic documentation of contents within retrieved, failed human titanium mesh cages...
  34. ncbi request reprint A retrospective view of seven specifically selected cases of patients with osteoporotic compression fractures and concomitant radiculopathy
    Isador H Lieberman
    Section of Spinal Surgery, Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Ohio, USA
    J Spinal Disord Tech 15:468. 2002
  35. ncbi request reprint A molecular gram stain using broad range PCR and pyrosequencing technology: a potentially useful tool for diagnosing orthopaedic infections
    Naomi Kobayashi
    Department of Anatomic Pathology, The Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA
    Diagn Mol Pathol 14:83-9. 2005
    ..This study demonstrates that high sensitivity and specificity of a molecular gram stain may be achieved using broad-range real-time PCR and pyrosequencing...
  36. ncbi request reprint Kyphoplasty: vertebral augmentation for compression fractures
    Daniel Shedid
    Centre Hospitalier de l Universite de Montreal, Notre Dame Hospital Division of Neurosurgery, 1560 Sherbrooke East, Montreal, Quebec H4L 2M1, Canada
    Clin Geriatr Med 22:535-44. 2006
    ..This technique may prevent propagation of further fractures by reducing the col-lapsed vertebral bodies toward its native height, normalizing the sagittal spinal alignment and the force transmission along the spine...
  37. ncbi request reprint Disc bulge bubble: spine economics 101
    Isador H Lieberman
    Spine J 4:609-13. 2004