Gusphyl Justin

Summary

Affiliation: Clemson University
Country: USA

Publications

  1. doi request reprint Biomimetic hydrogels for biosensor implant biocompatibility: electrochemical characterization using micro-disc electrode arrays (MDEAs)
    Gusphyl Justin
    Center for Bioelectronics, Biosensors and Biochips C3B, Clemson University Advanced Materials Center, 100 Technology Drive, Anderson, SC 29625, USA
    Biomed Microdevices 11:103-15. 2009
  2. doi request reprint Towards an implantable biochip for glucose and lactate monitoring using microdisc electrode arrays (MDEAs)
    Abdur Rub Abdur Rahman
    Center for Bioelectronics, Biosensors and Biochips C3B, Clemson University, 100 Technology Drive, Anderson, SC 29625, USA
    Biomed Microdevices 11:75-85. 2009
  3. doi request reprint Characterization of electroconductive blends of poly(HEMA-co-PEGMA-co-HMMA-co-SPMA) and poly(Py-co-PyBA)
    Gusphyl Justin
    Center for Bioelectronics, Biosensors and Biochips, Clemson University Advanced Materials Center, 100 Technology Drive, Anderson, South Carolina 29625, USA
    Biomacromolecules 10:2539-49. 2009

Detail Information

Publications3

  1. doi request reprint Biomimetic hydrogels for biosensor implant biocompatibility: electrochemical characterization using micro-disc electrode arrays (MDEAs)
    Gusphyl Justin
    Center for Bioelectronics, Biosensors and Biochips C3B, Clemson University Advanced Materials Center, 100 Technology Drive, Anderson, SC 29625, USA
    Biomed Microdevices 11:103-15. 2009
    ..1 to 7.2 and a 20% drop between pH 6.1 and 8.8...
  2. doi request reprint Towards an implantable biochip for glucose and lactate monitoring using microdisc electrode arrays (MDEAs)
    Abdur Rub Abdur Rahman
    Center for Bioelectronics, Biosensors and Biochips C3B, Clemson University, 100 Technology Drive, Anderson, SC 29625, USA
    Biomed Microdevices 11:75-85. 2009
    ..A generalized electronics platform based on the Texas Instruments TI NC01101 chip has been developed that may be readily applied to many types of biotransducers with minor modifications...
  3. doi request reprint Characterization of electroconductive blends of poly(HEMA-co-PEGMA-co-HMMA-co-SPMA) and poly(Py-co-PyBA)
    Gusphyl Justin
    Center for Bioelectronics, Biosensors and Biochips, Clemson University Advanced Materials Center, 100 Technology Drive, Anderson, South Carolina 29625, USA
    Biomacromolecules 10:2539-49. 2009
    ..Signal enhancement was achieved by modifying the surface of an MDEA biotransducer with the ECH, with a 10-fold increase in the voltammetric current response associated with the ferrocene monocarboxylic acid (FcCO(2)H) redox reaction...