Jeffrey S Reynolds

Summary

Affiliation: Centers for Disease Control and Prevention
Country: USA

Publications

  1. ncbi request reprint Nonlinear model for offline correction of pulmonary waveform generators
    Jeffrey S Reynolds
    Engineering and Controls Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV 26505, USA
    IEEE Trans Biomed Eng 49:1567-73. 2002
  2. doi request reprint Noninvasive pulmonary function screening in spontaneously breathing rodents: an engineering systems perspective
    Jeffrey S Reynolds
    Pathology and Physiology Research Branch, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1095 Willowdale Road, Morgantown, WV 26505, USA
    Pharmacol Ther 131:359-68. 2011
  3. doi request reprint Pulmonary effects after acute inhalation of oil dispersant (COREXIT EC9500A) in rats
    Jenny R Roberts
    Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, West Virginia 26505, USA
    J Toxicol Environ Health A 74:1381-96. 2011
  4. ncbi request reprint Model predictions of the recruitment of lung units and the lung surface area-volume relationship during inflation
    David G Frazer
    Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV 26505, USA
    Ann Biomed Eng 32:756-63. 2004
  5. doi request reprint Unrestrained acoustic plethysmograph for measuring specific airway resistance in mice
    Jeffrey S Reynolds
    Pathology and Physiology Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, 1095 Willowdale Rd, ms L2101, Morgantown, WV 26505, USA
    J Appl Physiol 105:711-7. 2008
  6. pmc Effects of titanium dioxide nanoparticle exposure on neuroimmune responses in rat airways
    Mario Scuri
    Department of Pediatrics, West Virginia University School of Medicine, Morgantown, West Virginia 26506, USA
    J Toxicol Environ Health A 73:1353-69. 2010
  7. doi request reprint Dispersion and exposure to a cough-generated aerosol in a simulated medical examination room
    William G Lindsley
    National Institute for Occupational Safety and Health, Health Effects Laboratory Division, 1095 Willowdale Road, Morgantown, WV 26505 2845, USA
    J Occup Environ Hyg 9:681-90. 2012
  8. doi request reprint Determining when enhanced pause (Penh) is sensitive to changes in specific airway resistance
    David G Frazer
    Pathology and Physiology Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, West Virginia 26505, USA
    J Toxicol Environ Health A 74:287-95. 2011
  9. pmc Inhalation of ortho-phthalaldehyde vapor causes respiratory sensitization in mice
    Victor J Johnson
    Toxicology and Molecular Biology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505 2888, USA
    J Allergy (Cairo) 2011:751052. 2011
  10. ncbi request reprint Unrestrained acoustic plethysmograph for measuring tidal volume in mice
    Jeffrey S Reynolds
    Pathology and Physiology Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV 26505, USA
    Ann Biomed Eng 34:1494-9. 2006

Collaborators

Detail Information

Publications11

  1. ncbi request reprint Nonlinear model for offline correction of pulmonary waveform generators
    Jeffrey S Reynolds
    Engineering and Controls Technology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV 26505, USA
    IEEE Trans Biomed Eng 49:1567-73. 2002
    ..0%. When loaded with the Micro DiaryCard meter, the uncorrected pump outputs included six waveforms with MSE higher than 0.001 L2/s2. Pump corrections for these six waveforms resulted in a mean decrease in MSE of 58.4%...
  2. doi request reprint Noninvasive pulmonary function screening in spontaneously breathing rodents: an engineering systems perspective
    Jeffrey S Reynolds
    Pathology and Physiology Research Branch, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, 1095 Willowdale Road, Morgantown, WV 26505, USA
    Pharmacol Ther 131:359-68. 2011
    ..This model is used as a basis to demonstrate the relationship between pulmonary parameters derived from circuit analysis...
  3. doi request reprint Pulmonary effects after acute inhalation of oil dispersant (COREXIT EC9500A) in rats
    Jenny R Roberts
    Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, West Virginia 26505, USA
    J Toxicol Environ Health A 74:1381-96. 2011
    ..COREXIT inhibited neurogenic contractile responses of strips to electrical field stimulation. Our findings suggest that COREXIT inhalation did not initiate lung inflammation, but may transiently increase the difficulty of breathing...
  4. ncbi request reprint Model predictions of the recruitment of lung units and the lung surface area-volume relationship during inflation
    David G Frazer
    Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV 26505, USA
    Ann Biomed Eng 32:756-63. 2004
    ..86 and 1. This result supports the theory that, for inflation from EEPs below 4 cmH2O, lung expansion occurs in part by the recruitment of lung units and not solely by the expansion of open units...
  5. doi request reprint Unrestrained acoustic plethysmograph for measuring specific airway resistance in mice
    Jeffrey S Reynolds
    Pathology and Physiology Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, 1095 Willowdale Rd, ms L2101, Morgantown, WV 26505, USA
    J Appl Physiol 105:711-7. 2008
    ..s. A dose-dependent increase in sRaw was shown, with an approximate tripling of sRaw at the highest dose. These results demonstrate the ability of the system to estimate sRaw based on plethysmograph airflow and acoustic amplitude...
  6. pmc Effects of titanium dioxide nanoparticle exposure on neuroimmune responses in rat airways
    Mario Scuri
    Department of Pediatrics, West Virginia University School of Medicine, Morgantown, West Virginia 26506, USA
    J Toxicol Environ Health A 73:1353-69. 2010
    ..These results suggest the presence of a critical window of vulnerability in earlier stages of lung development, which may lead to a higher risk of developing asthma...
  7. doi request reprint Dispersion and exposure to a cough-generated aerosol in a simulated medical examination room
    William G Lindsley
    National Institute for Occupational Safety and Health, Health Effects Laboratory Division, 1095 Willowdale Road, Morgantown, WV 26505 2845, USA
    J Occup Environ Hyg 9:681-90. 2012
    ....
  8. doi request reprint Determining when enhanced pause (Penh) is sensitive to changes in specific airway resistance
    David G Frazer
    Pathology and Physiology Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, West Virginia 26505, USA
    J Toxicol Environ Health A 74:287-95. 2011
    ..That relationship is used to describe the conditions under which whole-body plethysmograph Penh measurements can be used to detect changes in sRaw...
  9. pmc Inhalation of ortho-phthalaldehyde vapor causes respiratory sensitization in mice
    Victor J Johnson
    Toxicology and Molecular Biology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505 2888, USA
    J Allergy (Cairo) 2011:751052. 2011
    ..Mice exposed to the higher concentrations of OPA-produced OPA-specific IgG(1) antibodies indicating systemic sensitization. These findings provide evidence that OPA has the potential to cause respiratory sensitization in mice...
  10. ncbi request reprint Unrestrained acoustic plethysmograph for measuring tidal volume in mice
    Jeffrey S Reynolds
    Pathology and Physiology Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, WV 26505, USA
    Ann Biomed Eng 34:1494-9. 2006
    ..The RMS error between measured and delivered volume was 4.43 microL. A volume step test, performed to assess the response time of the system, showed that the plethysmograph responded in less than one millisecond...
  11. ncbi request reprint Metal working fluids: sub-chronic effects on pulmonary functions in B6C3F1 mice given vitamin E deficient and sufficient diets
    Anna A Shvedova
    Pathology and Physiology Research Branch, Engineering Control and Technology Branch, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505, USA
    Toxicology 177:285-97. 2002
    ..This is the first report that describes the increase of oxidative stress in the lungs after MWF exposure...