Patrick J McCormickSummaryAffiliation: Bausch and Lomb Country: USA Publications Validation of the Scan RDI for routine microbiological analysis of process waterStephen P Costanzo Bausch and Lomb, 1400 N Goodman St, PO Box 30450, Rochester, NY 14603 0450, USA PDA J Pharm Sci Technol 56:206-19 Qualification of a rapid readout biological indicator with moist heat sterilizationPatrick McCormick Bausch and Lomb, Microbiological and Sterilization Sciences, Rochester, NY 14603 0450, USA PDA J Pharm Sci Technol 57:25-31 A designed experiment for evaluation of the OPA method for cleaning studies of medical devicesPatrick J McCormick Bausch and Lomb, Inc, USA Biomed Instrum Technol 41:324-31 Comparative antimicrobial activity of no-rub multipurpose lens care solutions in the presence of organic soilDeborah McGrath ol>Bausch and Lomb Incorporated, Rochester, NY, USA Eye Contact Lens 29:245-9 | Collaborators
|
Detail Information
Publications
Validation of the Scan RDI for routine microbiological analysis of process waterStephen P Costanzo
Bausch and Lomb, 1400 N Goodman St, PO Box 30450, Rochester, NY 14603 0450, USA
PDA J Pharm Sci Technol 56:206-19
Bausch and Lomb, 1400 N Goodman St, PO Box 30450, Rochester, NY 14603 0450, USA
PDA J Pharm Sci Technol 56:206-19
..The results of the study indicate that the Scan RDI can be validated for routine use in a pharmaceutical environment and provide results equivalent to current methods, but in a much shorter time frame...
Qualification of a rapid readout biological indicator with moist heat sterilizationPatrick McCormick
Bausch and Lomb, Microbiological and Sterilization Sciences, Rochester, NY 14603 0450, USA
PDA J Pharm Sci Technol 57:25-31
Bausch and Lomb, Microbiological and Sterilization Sciences, Rochester, NY 14603 0450, USA
PDA J Pharm Sci Technol 57:25-31
..33, "Evaluation, Validation and Implementation of New Microbiological Testing Methods"...
A designed experiment for evaluation of the OPA method for cleaning studies of medical devicesPatrick J McCormick
Bausch and Lomb, Inc, USA
Biomed Instrum Technol 41:324-31
Bausch and Lomb, Inc, USA
Biomed Instrum Technol 41:324-31
..The components of the microkeratome contaminated with the test soil were successfully cleaned in an automated washer-disinfector using a neutral pH detergent and the procedure as described...
Comparative antimicrobial activity of no-rub multipurpose lens care solutions in the presence of organic soilDeborah McGrath
Bausch and Lomb Incorporated, Rochester, NY, USA
Eye Contact Lens 29:245-9
Bausch and Lomb Incorporated, Rochester, NY, USA
Eye Contact Lens 29:245-9
..The overall reduction in antimicrobial activity depends on the solution and organism...
ol>