Adrian Bradu

Summary

Affiliation: University of Kent
Country: UK

Publications

  1. doi request reprint Fourier domain optical coherence tomography system with balance detection
    Adrian Bradu
    Applied Optics Group, School of Physical Sciences, University of Kent, Canterbury, CT2 7NH, UK
    Opt Express 20:17522-38. 2012
  2. doi request reprint Attenuation of mirror image and enhancement of the signal-to-noise ratio in a Talbot bands optical coherence tomography system
    Adrian Bradu
    University of Kent, School of Physical Sciences, Applied Optics Group, Gilles Lane, Canterbury, Kent CT2 7NH United Kingdom
    J Biomed Opt 16:076010. 2011
  3. doi request reprint Dual optical coherence tomography/fluorescence microscopy for monitoring of Drosophila melanogaster larval heart
    Adrian Bradu
    Applied Optics Group, School of Physical Sciences, University of Kent, CT2 7NH Canterbury, UK
    J Biophotonics 2:380-8. 2009
  4. doi request reprint Extra long imaging range swept source optical coherence tomography using re-circulation loops
    Adrian Bradu
    Applied Optics Group, School of Physical Sciences, University of Kent, Canterbury, Kent, CT2 7NH, UK
    Opt Express 18:25361-70. 2010
  5. doi request reprint Multiple-depth en face optical coherence tomography using active recirculation loops
    Liviu Neagu
    Applied Optics Group, School of Physical Sciences, University of Kent, CT2 7NH Canterbury, UK
    Opt Lett 35:2296-8. 2010
  6. doi request reprint Gabor fusion technique in a Talbot bands optical coherence tomography system
    Petr Bouchal
    Applied Optics Group, School of Physical Sciences, University of Kent, Canterbury, Kent CT2 7NH, United Kingdom
    Opt Express 20:5368-83. 2012
  7. pmc Arrhythmia caused by a Drosophila tropomyosin mutation is revealed using a novel optical coherence tomography instrument
    Lisha Ma
    Cell and Developmental Biology Group, School of Biosciences, University of Kent, Canterbury, Kent, United Kingdom
    PLoS ONE 5:e14348. 2010
  8. pmc Dual instrument for in vivo and ex vivo OCT imaging in an ENT department
    Ramona Cernat
    Applied Optics Group, School of Physical Sciences, University of Kent, CT2 7NH Canterbury, UK
    Biomed Opt Express 3:3346-56. 2012
  9. doi request reprint Polarization maintaining multiple-depth en face optical coherence tomography system using active re-circulation loops in the non-stationary state
    John A Rogers
    Applied Optics Group, School of Physical Sciences, University of Kent, CT2 7NH Canterbury, UK
    Opt Express 20:29196-209. 2012
  10. pmc Frequency multiplexed long range swept source optical coherence tomography
    Mantas Zurauskas
    Applied Optics Group, School of Physical Sciences, University of Kent, CT2 7NH Canterbury, UK
    Biomed Opt Express 4:778-88. 2013

Collaborators

Detail Information

Publications11

  1. doi request reprint Fourier domain optical coherence tomography system with balance detection
    Adrian Bradu
    Applied Optics Group, School of Physical Sciences, University of Kent, Canterbury, CT2 7NH, UK
    Opt Express 20:17522-38. 2012
    ..However, simple deduction of an average spectrum in single camera configurations delivers less noise than the balance detection...
  2. doi request reprint Attenuation of mirror image and enhancement of the signal-to-noise ratio in a Talbot bands optical coherence tomography system
    Adrian Bradu
    University of Kent, School of Physical Sciences, Applied Optics Group, Gilles Lane, Canterbury, Kent CT2 7NH United Kingdom
    J Biomed Opt 16:076010. 2011
    ..We demonstrate the efficiency of such a configuration at large depths by imaging a thick phantom and human skin in vivo for different values of the lateral distance between the two beams...
  3. doi request reprint Dual optical coherence tomography/fluorescence microscopy for monitoring of Drosophila melanogaster larval heart
    Adrian Bradu
    Applied Optics Group, School of Physical Sciences, University of Kent, CT2 7NH Canterbury, UK
    J Biophotonics 2:380-8. 2009
    ..With this dual-imaging system, the heart can be easily located and visualized within the specimen and the change of the heart shape in a cardiac cycle can be monitored...
  4. doi request reprint Extra long imaging range swept source optical coherence tomography using re-circulation loops
    Adrian Bradu
    Applied Optics Group, School of Physical Sciences, University of Kent, Canterbury, Kent, CT2 7NH, UK
    Opt Express 18:25361-70. 2010
    ..In this way, the axial imaging range in SS-OCT can be pushed well beyond the limit imposed by the coherence length of the laser, to exceed in principle many centimeters...
  5. doi request reprint Multiple-depth en face optical coherence tomography using active recirculation loops
    Liviu Neagu
    Applied Optics Group, School of Physical Sciences, University of Kent, CT2 7NH Canterbury, UK
    Opt Lett 35:2296-8. 2010
    ..This configuration is employed to demonstrate simultaneous en face optical coherence tomography imaging at five different depths in a Drosophila melanogaster fly...
  6. doi request reprint Gabor fusion technique in a Talbot bands optical coherence tomography system
    Petr Bouchal
    Applied Optics Group, School of Physical Sciences, University of Kent, Canterbury, Kent CT2 7NH, United Kingdom
    Opt Express 20:5368-83. 2012
    ..Future cameras with larger pixel size may take full advantage of the TB/GF procedure proposed here...
  7. pmc Arrhythmia caused by a Drosophila tropomyosin mutation is revealed using a novel optical coherence tomography instrument
    Lisha Ma
    Cell and Developmental Biology Group, School of Biosciences, University of Kent, Canterbury, Kent, United Kingdom
    PLoS ONE 5:e14348. 2010
    ..Such a system needs a genetically manipulable model organism that allows in vivo measurement of cardiac phenotypes and a detecting instrument capable of recording multiple phenotype parameters...
  8. pmc Dual instrument for in vivo and ex vivo OCT imaging in an ENT department
    Ramona Cernat
    Applied Optics Group, School of Physical Sciences, University of Kent, CT2 7NH Canterbury, UK
    Biomed Opt Express 3:3346-56. 2012
    ....
  9. doi request reprint Polarization maintaining multiple-depth en face optical coherence tomography system using active re-circulation loops in the non-stationary state
    John A Rogers
    Applied Optics Group, School of Physical Sciences, University of Kent, CT2 7NH Canterbury, UK
    Opt Express 20:29196-209. 2012
    ..The effect of these improvements resulted in a decay less than 20 dB from the 1st channel to the 10th channel...
  10. pmc Frequency multiplexed long range swept source optical coherence tomography
    Mantas Zurauskas
    Applied Optics Group, School of Physical Sciences, University of Kent, CT2 7NH Canterbury, UK
    Biomed Opt Express 4:778-88. 2013
    ..Then the configuration is employed to demonstrate long range B-scan imaging by combining two simultaneous B-scans from a mouse head sample...
  11. ncbi request reprint Evaluation of effective noise bandwidth for broadband optical coherence tomography operation
    Ramona Cernat
    Applied Optics Group, University of Kent, Canterbury, CT2 7NH, UK
    J Opt Soc Am A Opt Image Sci Vis 26:723-31. 2009
    ..We show that under certain operating parameters, the additional excess photon noise is twice that predicted for a coupler with a flat spectral response...