  1. doi request reprint The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip
    D J Langton
    Joint Replacement Unit, University Hospital of North Tees, Hardwick, Stockton on Tees TS19 8PE, UK
    J Bone Joint Surg Br 90:1143-51. 2008
  2. doi request reprint Blood metal ion concentrations after hip resurfacing arthroplasty: a comparative study of articular surface replacement and Birmingham Hip Resurfacing arthroplasties
    D J Langton
    Joint Replacement Unit, University Hospital of North Tees, Hardwick, Stockton on Tees, UK
    J Bone Joint Surg Br 91:1287-95. 2009
  3. doi request reprint Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A consequence of excess wear
    D J Langton
    North Tees and Hartlepool NHS Trust, Stockton on Tees and Centre for Rehabilitation, Newcastle University, Newcastle upon Tyne, England
    J Bone Joint Surg Br 92:38-46. 2010
  4. doi request reprint Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear
    D J Langton
    Northern Deanery, Goldcrest Way, Newcastle upon Tyne, NE15 8NY, UK
    J Bone Joint Surg Br 93:164-71. 2011
  5. doi request reprint Reducing metal ion release following hip resurfacing arthroplasty
    David J Langton
    Joint Replacement Unit, University Hospital of North Tees, Hardwick, Stockton on Tees, UK
    Orthop Clin North Am 42:169-80, viii. 2011
  6. doi request reprint Accelerating failure rate of the ASR total hip replacement
    D J Langton
    Northern Deanery, Goldcrest Way, Newcastle upon Tyne NE15 8NY, UK
    J Bone Joint Surg Br 93:1011-6. 2011
  7. doi request reprint Ten-year clinical, radiological and metal ion analysis of the Birmingham Hip Resurfacing: from a single, non-designer surgeon
    J P Holland
    Freeman Hospital, Freeman Road, High Heaton, Newcastle upon Tyne, Tyne and Wear NE7 7DN, UK
    J Bone Joint Surg Br 94:471-6. 2012
  8. doi request reprint Articular surface replacement of the hip: a prospective single-surgeon series
    S S Jameson
    University Hospital of North Tees, Hardwick, Stockton on Tees, England
    J Bone Joint Surg Br 92:28-37. 2010
  9. pmc Taper junction failure in large-diameter metal-on-metal bearings
    D J Langton
    University Hospital of North Tees, Hardwick Road, Stockton TS19 8PE, UK
    Bone Joint Res 1:56-63. 2012

Collaborators

Detail Information

Publications9

  1. doi request reprint The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip
    D J Langton
    Joint Replacement Unit, University Hospital of North Tees, Hardwick, Stockton on Tees TS19 8PE, UK
    J Bone Joint Surg Br 90:1143-51. 2008
    ..Accurate positioning of the acetabular component intra-operatively is essential in order to reduce the concentration of metal ions in the blood after hip resurfacing arthroplasty with the Articular Surface Replacement implant...
  2. doi request reprint Blood metal ion concentrations after hip resurfacing arthroplasty: a comparative study of articular surface replacement and Birmingham Hip Resurfacing arthroplasties
    D J Langton
    Joint Replacement Unit, University Hospital of North Tees, Hardwick, Stockton on Tees, UK
    J Bone Joint Surg Br 91:1287-95. 2009
    ..001). This indicates that reduced diametral clearance may equate to a reduction in metal ion concentrations in larger joints with satisfactory orientation of the acetabular component...
  3. doi request reprint Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A consequence of excess wear
    D J Langton
    North Tees and Hartlepool NHS Trust, Stockton on Tees and Centre for Rehabilitation, Newcastle University, Newcastle upon Tyne, England
    J Bone Joint Surg Br 92:38-46. 2010
    ..Surgeons must consider implant design, expected component size and acetabular component positioning in order to reduce early failures when performing large-bearing metal-on-metal hip resurfacing and replacement...
  4. doi request reprint Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear
    D J Langton
    Northern Deanery, Goldcrest Way, Newcastle upon Tyne, NE15 8NY, UK
    J Bone Joint Surg Br 93:164-71. 2011
    ..However, the extent of tissue destruction at revision surgery did not appear to be dose-related to the volumetric wear...
  5. doi request reprint Reducing metal ion release following hip resurfacing arthroplasty
    David J Langton
    Joint Replacement Unit, University Hospital of North Tees, Hardwick, Stockton on Tees, UK
    Orthop Clin North Am 42:169-80, viii. 2011
    ....
  6. doi request reprint Accelerating failure rate of the ASR total hip replacement
    D J Langton
    Northern Deanery, Goldcrest Way, Newcastle upon Tyne NE15 8NY, UK
    J Bone Joint Surg Br 93:1011-6. 2011
    ..Our results suggest that wear at the modular junction is an important factor in the development of adverse tissue reactions after implantation of a large-diameter MoM THR...
  7. doi request reprint Ten-year clinical, radiological and metal ion analysis of the Birmingham Hip Resurfacing: from a single, non-designer surgeon
    J P Holland
    Freeman Hospital, Freeman Road, High Heaton, Newcastle upon Tyne, Tyne and Wear NE7 7DN, UK
    J Bone Joint Surg Br 94:471-6. 2012
    ..The overall results were consistent with data produced from other centres in that the clinical outcome of large male patients was extremely encouraging, whereas the survival of the smaller joints was less satisfactory...
  8. doi request reprint Articular surface replacement of the hip: a prospective single-surgeon series
    S S Jameson
    University Hospital of North Tees, Hardwick, Stockton on Tees, England
    J Bone Joint Surg Br 92:28-37. 2010
    ..These changes may contribute to the higher failure rate than in other series, compared with other designs. Given our poor results with the small components we are no longer implanting the smaller size...
  9. pmc Taper junction failure in large-diameter metal-on-metal bearings
    D J Langton
    University Hospital of North Tees, Hardwick Road, Stockton TS19 8PE, UK
    Bone Joint Res 1:56-63. 2012
    ..We report on the results of the analysis of the first consecutive 126 failed mated total hip prostheses from a single manufacturer...