O P P Temmerman

Summary

Affiliation: VU University Medical Center
Country: The Netherlands

Publications

  1. ncbi A comparison of radiographic and scintigraphic techniques to assess aseptic loosening of the acetabular component in a total hip replacement
    Olivier P P Temmerman
    Department of Nuclear Medicine, VU University Medical Centre, De Boelelaan 1117, 1007 MB Amsterdam, The Netherlands
    J Bone Joint Surg Am 86:2456-63. 2004
  2. ncbi The value of contrast and subtraction arthrography in the assessment of aseptic loosening of total hip prostheses: a meta-analysis
    Olivier P P Temmerman
    Department of Nuclear Medicine and PET Research, VU University Medical Centre, Boelelaan 1117, 1007 MB Amsterdam, The Netherlands
    Eur J Radiol 56:113-9. 2005
  3. ncbi Accuracy of diagnostic imaging techniques in the diagnosis of aseptic loosening of the femoral component of a hip prosthesis: a meta-analysis
    O P P Temmerman
    Department of Clinical Epidemiology and Biostatistics, VU University Medical Centre, Boelalaan 1117, 1007 MB Amsterdam, The Netherlands
    J Bone Joint Surg Br 87:781-5. 2005
  4. ncbi Diagnostic accuracy and interobserver variability of plain radiography, subtraction arthrography, nuclear arthrography, and bone scintigraphy in the assessment of aseptic femoral component loosening
    Olivier P P Temmerman
    Department of Nuclear Medicine, VU University Medical Centre, Boelelaan 1117, 1007, Amsterdam, The Netherlands
    Arch Orthop Trauma Surg 126:316-23. 2006
  5. pmc Bone metabolism after total hip revision surgery with impacted grafting: evaluation using H2 15O and [18F]fluoride PET; a pilot study
    Olivier P P Temmerman
    Department of Nuclear Medicine and PET Research, VU University Medical Centre, Amsterdam, The Netherlands
    Mol Imaging Biol 10:288-93. 2008
  6. ncbi The use of plain radiography, subtraction arthrography, nuclear arthrography, and bone scintigraphy in the diagnosis of a loose acetabular component of a total hip prosthesis: a systematic review
    Olivier P P Temmerman
    Department of Nuclear Medicine, VU University Medical Center, Amsterdam, The Netherlands
    J Arthroplasty 22:818-27. 2007

Detail Information

Publications6

  1. ncbi A comparison of radiographic and scintigraphic techniques to assess aseptic loosening of the acetabular component in a total hip replacement
    Olivier P P Temmerman
    Department of Nuclear Medicine, VU University Medical Centre, De Boelelaan 1117, 1007 MB Amsterdam, The Netherlands
    J Bone Joint Surg Am 86:2456-63. 2004
    ..In this retrospective study, we evaluated the sensitivity, specificity, and interobserver reliability of these imaging modalities in patients suspected of having aseptic loosening of the acetabular component...
  2. ncbi The value of contrast and subtraction arthrography in the assessment of aseptic loosening of total hip prostheses: a meta-analysis
    Olivier P P Temmerman
    Department of Nuclear Medicine and PET Research, VU University Medical Centre, Boelelaan 1117, 1007 MB Amsterdam, The Netherlands
    Eur J Radiol 56:113-9. 2005
    ..To summarize and compare the diagnostic accuracy of contrast and subtraction arthrography in the assessment of aseptic loosening of total hip arthroplasties...
  3. ncbi Accuracy of diagnostic imaging techniques in the diagnosis of aseptic loosening of the femoral component of a hip prosthesis: a meta-analysis
    O P P Temmerman
    Department of Clinical Epidemiology and Biostatistics, VU University Medical Centre, Boelalaan 1117, 1007 MB Amsterdam, The Netherlands
    J Bone Joint Surg Br 87:781-5. 2005
    ....
  4. ncbi Diagnostic accuracy and interobserver variability of plain radiography, subtraction arthrography, nuclear arthrography, and bone scintigraphy in the assessment of aseptic femoral component loosening
    Olivier P P Temmerman
    Department of Nuclear Medicine, VU University Medical Centre, Boelelaan 1117, 1007, Amsterdam, The Netherlands
    Arch Orthop Trauma Surg 126:316-23. 2006
    ..Controversy exists about the relative utility of these techniques...
  5. pmc Bone metabolism after total hip revision surgery with impacted grafting: evaluation using H2 15O and [18F]fluoride PET; a pilot study
    Olivier P P Temmerman
    Department of Nuclear Medicine and PET Research, VU University Medical Centre, Amsterdam, The Netherlands
    Mol Imaging Biol 10:288-93. 2008
    ..To evaluate bone blood flow and bone formation in patients after total hip revision surgery with impacted bone grafting using H2 15O and [18F]fluoride positron emission tomography (PET)...
  6. ncbi The use of plain radiography, subtraction arthrography, nuclear arthrography, and bone scintigraphy in the diagnosis of a loose acetabular component of a total hip prosthesis: a systematic review
    Olivier P P Temmerman
    Department of Nuclear Medicine, VU University Medical Center, Amsterdam, The Netherlands
    J Arthroplasty 22:818-27. 2007
    ..Therefore, subtraction arthrography is recommended for use as an additional diagnostic technique when plain radiography is found to be inconclusive...