Research Topics
| Jelle BarentszSummaryAffiliation: Radboud University Nijmegen Medical Centre Country: The Netherlands Publications
| Collaborators
|
Detail Information
Publications
ESUR prostate MR guidelines 2012Jelle O Barentsz
Department of Radiology, Radboud University Nijmegen Medical Center, Nijmegen, The Netherlands
Eur Radiol 22:746-57. 2012..Clinical indications, and minimal and optimal imaging acquisition protocols are provided. A structured reporting system (PI-RADS) is described...
Commonly used imaging techniques for diagnosis and stagingJelle Barentsz
Department of Radiology, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands
J Clin Oncol 24:3234-44. 2006..Given that each technique has its inherent strengths and weaknesses, the combination of the methods will result in improved diagnosis, staging, and treatment prediction and monitoring...
Use of ultrasmall superparamagnetic iron oxide in lymph node MR imaging in prostate cancer patientsJelle O Barentsz
Department of Radiology, Radboud University Nijmegen Medical Center, The Netherlands
Eur J Radiol 63:369-72. 2007..However, thorough knowledge of sequence parameters and planes, lymph node anatomy, appearance of normal and abnormal nodes, is essential when using this technique. This will be elaborated in this review...
MRI with a lymph-node-specific contrast agent as an alternative to CT scan and lymph-node dissection in patients with prostate cancer: a prospective multicohort studyRoel A M Heesakkers
Department of Radiology, Radboud University Medical Centre, Nijmegen, Netherlands
Lancet Oncol 9:850-6. 2008..In this prospective, multicentre cohort study, we aimed to compare the diagnostic accuracy of MRL with up-to-date multidetector CT (MDCT), and test the hypothesis that a negative MRL finding obviates the need for a PLND...
Prostate cancer: detection of lymph node metastases outside the routine surgical area with ferumoxtran-10-enhanced MR imagingRoel A M Heesakkers
Department of Radiology, University Medical Center Nijmegen, Geert Grooteplein zuid 10, NL 650 HB Nijmegen, The Netherlands
Radiology 251:408-14. 2009..To prospectively evaluate the feasibility of magnetic resonance (MR) imaging with ferumoxtran-10 in patients with prostate cancer to depict lymph node metastases outside the routine pelvic lymph node dissection (PLND) area...
Prospective assessment of prostate cancer aggressiveness using 3-T diffusion-weighted magnetic resonance imaging-guided biopsies versus a systematic 10-core transrectal ultrasound prostate biopsy cohortThomas Hambrock
Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
Eur Urol 61:177-84. 2012..Diffusion-weighted magnetic resonance imaging (MRI) has been shown to be a biomarker of tumour aggressiveness...
Three-dimensional proton MR spectroscopy of human prostate at 3 T without endorectal coil: feasibilityTom W J Scheenen
Department of Radiology, Radboud University Nijmegen Medical Centre, Geert Grooteplein 10, 6525 GA, Nijmegen, The Netherlands
Radiology 245:507-16. 2007....
Automated analysis of contrast enhancement in breast MRI lesions using mean shift clustering for ROI selectionMark J Stoutjesdijk
Radboud University Medical Centre, Department of Radiology, Nijmegen, The Netherlands
J Magn Reson Imaging 26:606-14. 2007..To evaluate a new method for automated determination of a region of interest (ROI) for the analysis of contrast enhancement in breast MRI...
Contrast-enhanced versus systematic transrectal ultrasound-guided prostate cancer detection: an overview of techniques and a systematic reviewStijn W T P J Heijmink
Department of Radiology, Radboud University Nijmegen Medical Centre, Geert Grooteplein zuid 10, NL 6500 HB Nijmegen, The Netherlands
Eur J Radiol 63:310-6. 2007..Future randomized clinical trials, preferably in a non-academic multi-institutional set-up, will have to be performed to confirm the value of contrast-enhanced-targeted TRUS-guided biopsy in regular clinical practice...
Standardized threshold approach using three-dimensional proton magnetic resonance spectroscopic imaging in prostate cancer localization of the entire prostateJurgen J Futterer
Department of Radiology, Radboud University Nijmegen Medical Center, The Netherlands
Invest Radiol 42:116-22. 2007..We sought to determine the localization accuracy using 3-dimensional (3D) proton magnetic resonance spectroscopic imaging (MRSI) of the entire prostate with a standardized thresholds approach in prostate cancer patients...
Prostate cancer localization with dynamic contrast-enhanced MR imaging and proton MR spectroscopic imagingJurgen J Futterer
Department of Radiology, Radboud University Nijmegen Medical Center, Geert Grooteplein zuid 10, NL 6500 HB, Nijmegen, The Netherlands
Radiology 241:449-58. 2006....
Prostate cancer: comparison of local staging accuracy of pelvic phased-array coil alone versus integrated endorectal-pelvic phased-array coils. Local staging accuracy of prostate cancer using endorectal coil MR imagingJurgen J Futterer
Department of Radiology, University Medical Center Nijmegen, Nijmegen, The Netherlands
Eur Radiol 17:1055-65. 2007..Overstaging is reduced significantly with equal sensitivity when an endorectal-pelvic phased-array coil is used...
Prostate and lymph node proton magnetic resonance (MR) spectroscopic imaging with external array coils at 3 T to detect recurrent prostate cancer after radiation therapyStijn W T P J Heijmink
Department of Radiology, Radboud University Nijmegen Medical Center, Nijmegen, The Netherlands
Invest Radiol 42:420-7. 2007..1 mmol/kg water. Subsequent histopathological analysis of systematic transrectal ultrasound-guided prostate biopsy and computed tomography-guided biopsy of the lymph node confirmed the presence of prostate cancer in both...
Prostate cancer: body-array versus endorectal coil MR imaging at 3 T--comparison of image quality, localization, and staging performanceStijn W T P J Heijmink
Department of Radiology, Radboud University Nijmegen Medical Centre, Geert Grooteplein zuid 10, NL 6500 HB, Nijmegen, The Netherlands
Radiology 244:184-95. 2007....
Preoperative 3T MR imaging of rectal cancer: local staging accuracy using a two-dimensional and three-dimensional T2-weighted turbo spin echo sequenceJurgen J Futterer
Department of Radiology, Radboud University Nijmegen Medical Center, The Netherlands
Eur J Radiol 65:66-71. 2008..The purpose of our study was to evaluate the image quality and diagnostic performance of two-dimensional (D) turbo spin echo (TSE) and 3D T2-weighted TSE MR imaging in local staging of rectal cancer at 3T...
Computerized analysis of prostate lesions in the peripheral zone using dynamic contrast enhanced MRIPieter C Vos
Department of Radiology, Radboud University Nijmegen Medical Centre, Geert Grooteplein 18, 6525 GA Nijmegen, The Netherlands
Med Phys 35:888-99. 2008..83 (0.75-0.92). This suggests that it is feasible to develop a computer aided diagnosis system capable of characterizing prostate cancer in the peripheral zone based on DCE-MRI...
Thirty-two-channel coil 3T magnetic resonance-guided biopsies of prostate tumor suspicious regions identified on multimodality 3T magnetic resonance imaging: technique and feasibilityThomas Hambrock
Department of Radiology, University Medical Centre Nijmegen, Nijmegen, Netherlands
Invest Radiol 43:686-94. 2008..Furthermore, to evaluate the practicability of MR-guided biopsy on a 3T MR scanner using a 32-channel coil and a MR-compatible biopsy device...
Perineal descent and patients' symptoms of anorectal dysfunction, pelvic organ prolapse, and urinary incontinenceSuzan R Broekhuis
791 Department of Obstetrics and Gynecology, Radboud University Nijmegen Medical Centre, PO Box 9101, 6500 HB Nijmegen, The Netherlands
Int Urogynecol J 21:721-9. 2010..The aim of this dynamic magnetic resonance (MR) imaging study was to assess the relation between the position and mobility of the perineum and patients' symptoms of pelvic floor dysfunction...
Feasibility of 3T dynamic contrast-enhanced magnetic resonance-guided biopsy in localizing local recurrence of prostate cancer after external beam radiation therapyDerya Yakar
Department of Radiology, Nijmegen Medical Centre, Radboud University, Nijmegen, The Netherlands
Invest Radiol 45:121-5. 2010....
[Multiparametric MRI for prostate cancer screening]Caroline M A Hoeks
Universitair Medisch Centrum St Radboud, Afd Radiologie, Nijmegen, The Netherlands
Ned Tijdschr Geneeskd 153:B487. 2009..Using multiparametric MRI as a follow-up test during screening would provide more accurate biopsies, prevent unnecessary prostate biopsies and improve the characterization of prostate cancer...
In vivo imaging of the aneurysm wall with MRI and a macrophage-specific contrast agentMaarten Truijers
Department of Surgery and Vascular Surgery, Radboud University, Nijmegen Medical Center, Gelderland, 6500HB Nijmegen, The Netherlands
AJR Am J Roentgenol 193:W437-41. 2009..We studied uptake of the macrophage-specific contrast agent ultrasmall paramagnetic iron oxide (USPIO) in the walls of aneurysms and normal-sized aortas...
Symptoms of pelvic floor dysfunction are poorly correlated with findings on clinical examination and dynamic MR imaging of the pelvic floorSuzan R Broekhuis
791 Department of Obstetrics and Gynecology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
Int Urogynecol J Pelvic Floor Dysfunct 20:1169-74. 2009..The aim of the study was to determine whether patients' symptoms agree with findings on clinical examination and dynamic MR imaging of the pelvic floor...
Magnetic resonance-guided biopsy of the prostate: feasibility, technique, and clinical applicationsDerya Yakar
Department of Radiology, Radboud University, Nijmegen Medical Centre, Geert Grooteplein Zuid, Nijmegen, The Netherlands
Top Magn Reson Imaging 19:291-5. 2008..To describe the technique of magnetic resonance (MR)-guided biopsy as performed in our institution and highlight trends from current literature...
Value of 3-T magnetic resonance imaging in local staging of prostate cancerJurgen J Futterer
Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
Top Magn Reson Imaging 19:285-9. 2008..Furthermore, the current diagnostic performance of prostate MR imaging in staging prostate cancer at high field strength is discussed...
A systematic review of clinical studies on dynamic magnetic resonance imaging of pelvic organ prolapse: the use of reference lines and anatomical landmarksSuzan R Broekhuis
Department of Obstetrics and Gynecology 791, Radboud University Nijmegen Medical Centre, Geert Grooteplein zuid 10, 6500 HB, Nijmegen, The Netherlands
Int Urogynecol J Pelvic Floor Dysfunct 20:721-9. 2009..The aim of our study was to provide a systematic literature review of clinical studies on pelvic organ prolapse staging with use of dynamic magnetic resonance (MR) imaging...
Changes in prostate shape and volume and their implications for radiotherapy after introduction of endorectal balloon as determined by MRI at 3TStijn W T P J Heijmink
Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
Int J Radiat Oncol Biol Phys 73:1446-53. 2009..To determine the changes in prostate shape and volume after the introduction of an endorectal coil (ERC) by means of magnetic resonance imaging (MRI) at 3T...
Dynamic magnetic resonance imaging: reliability of anatomical landmarks and reference lines used to assess pelvic organ prolapseSuzan R Broekhuis
Department of Obstetrics and Gynecology, Radboud University Nijmegen Medical Centre, P O Box 9101, 6500 HB, Nijmegen, The Netherlands
Int Urogynecol J Pelvic Floor Dysfunct 20:141-8. 2009..20-0.96). The intra- and interobserver reliability of quantitative prolapse staging on dynamic MR imaging were good to excellent. The pubococcygeal line appears the most reliable to use...
Prostate cancer: local staging at 3-T endorectal MR imaging--early experienceJurgen J Futterer
Department of Radiology, University Medical Center Nijmegen, Geert Grooteplein zuid 10, NL 6500 HB, Nijmegen, The Netherlands
Radiology 238:184-91. 2006..To prospectively investigate the local staging accuracy of 3-T endorectal magnetic resonance (MR) imaging for prostate cancer by using whole-mount-section histopathologic analysis as the standard of reference...
Initial experience of 3 tesla endorectal coil magnetic resonance imaging and 1H-spectroscopic imaging of the prostateJurgen J Futterer
Department of Radiology, University Medical Center Nijmegen, Nijmegen The Netherlands
Invest Radiol 39:671-80. 2004..We sought to explore the feasibility of magnetic resonance imaging (MRI) of the prostate at 3T, with the knowledge of potential drawbacks of MRI at high field strengths...
Urinary bladder cancer: preoperative nodal staging with ferumoxtran-10-enhanced MR imagingWillem M L L G Deserno
Department of Radiology, University Medical Center Sint Radboud, PO Box 9101, 6500 HB Nijmegen, The Netherlands
Radiology 233:449-56. 2004..To prospectively evaluate ferumoxtran-10-enhanced magnetic resonance (MR) imaging for nodal staging in patients with urinary bladder cancer...
Combined quantitative dynamic contrast-enhanced MR imaging and (1)H MR spectroscopic imaging of human prostate cancerFerdinand A van Dorsten
Department of Radiology, University Medical Center St. Radboud, Geert Grooteplein 10, Nijmegen, The Netherlands
J Magn Reson Imaging 20:279-87. 2004..J. Magn. Reson. Imaging 2004;20:279-287. Copyright 2004 Wiley-Liss, Inc...
Cost-analysis of staging methods for lymph nodes in patients with prostate cancer: MRI with a lymph node-specific contrast agent compared to pelvic lymph node dissection or CTAnke M Hövels
Department of Medical Technology Assessment, University Medical Centre Nijmegen, P O Box 9101, 6500 HB Nijmegen, The Netherlands
Eur Radiol 14:1707-12. 2004..Average costs of MRL staging in our institution are less than for CT and PLND in staging lymph nodes of patients with prostate cancer and who are intermediate or high risk for nodal metastases...
Fast acquisition-weighted three-dimensional proton MR spectroscopic imaging of the human prostateTom W J Scheenen
Department of Radiology, University Medical Center Nijmegen, Nijmegen, The Netherlands
Magn Reson Med 52:80-8. 2004..At 1.5 T, the MR-visible prostate metabolites citrate, creatine, and choline can now be mapped over the entire human prostate with uncontaminated spherical voxels, with a volume down to 0.37 cm3, in measurement times of 7-15 min...
The role of MRI in invasive lobular carcinomaCarla Boetes
Department of Radiology, University Medical Center Nijmegen, Nijmegen, The Netherlands
Breast Cancer Res Treat 86:31-7. 2004..To determine the value of MR imaging in the detection and measurement of tumor size in patients with invasive lobular carcinoma (ILC) compared to mammography and ultrasound...
PET/CT: panacea, redundancy, or something in between?Wouter V Vogel
Department of Nuclear Medicine, University Medical Center Nijmegen, Nijmegen, The Netherlands
J Nucl Med 45:15S-24S. 2004..The continuous development of better software for image fusion and respiratory and cardiac gating is also needed, not only for PET and CT imaging but also for fusion of PET with MRI and CT with MRI...
Discrimination of prostate cancer from normal peripheral zone and central gland tissue by using dynamic contrast-enhanced MR imagingMarc R Engelbrecht
Department of Radiology, University Medical Center Nijmegen, PO Box 9101, NL 6500 HB Nijmegen, The Netherlands
Radiology 229:248-54. 2003....
Method for quantitation of dynamic MRI contrast agent uptake in colorectal liver metastasesHanneke W M van Laarhoven
Department of Medical Oncology, University Medical Center Nijmegen, Nijmegen, The Netherlands
J Magn Reson Imaging 18:315-20. 2003....
Variability in the description of morphologic and contrast enhancement characteristics of breast lesions on magnetic resonance imagingMark J Stoutjesdijk
Radboud University Nijmegen Medical Centre, Department of Radiology, The Netherlands
Invest Radiol 40:355-62. 2005..The objective of this study was to evaluate the interobserver variability in reporting descriptive kinetic and morphologic enhancement features at breast magnetic resonance imaging...
Magnetic resonance-guided biopsies and localizations of the breast: initial experiences using an open breast coil and compatible intervention deviceJeroen Veltman
Department of Radiology, University Medical Center Nijmegen, The Netherlands
Invest Radiol 40:379-84. 2005..The objective of this study was to evaluate the performance of a new commercially available open breast coil and compatible intervention device (Machnet) for magnetic resonance image (MRI)-guided breast interventions...
Optimal timing for in vivo 1H-MR spectroscopic imaging of the human prostate at 3TTom W J Scheenen
Department of Radiology, University Medical Center Nijmegen, 6525 GA Nijmegen, The Netherlands
Magn Reson Med 53:1268-74. 2005..This is illustrated by means of a 3D spectroscopic imaging experiment in a complete prostate in vivo...
Prostate cancer evaluated with ferumoxtran-10-enhanced T2*-weighted MR Imaging at 1.5 and 3.0 T: early experienceRoel A M Heesakkers
Department of Radiology and Medical Technology Assessment, University Medical Center Nijmegen, Geert Grooteplein zuid 10, NL 6500 HB, Nijmegen, The Netherlands
Radiology 239:481-7. 2006..0 T) and to compare image quality between 1.5- and 3.0-T MR imaging in terms of lymph node detection in patients with prostate cancer...
IMRT boost dose planning on dominant intraprostatic lesions: gold marker-based three-dimensional fusion of CT with dynamic contrast-enhanced and 1H-spectroscopic MRIEmile N J T van Lin
Department of Radiation Oncology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
Int J Radiat Oncol Biol Phys 65:291-303. 2006....
A comparison of the diagnostic performance of systematic versus ultrasound-guided biopsies of prostate cancerStijn W T P J Heijmink
Department of Radiology, Radboud University Nijmegen Medical Centre, The Netherlands
Eur Radiol 16:927-38. 2006..Performing colour or contrast-enhanced Doppler biopsy or adding these techniques to systematic biopsies improves diagnostic performance, particularly by increasing sensitivity...
Staging prostate cancer with dynamic contrast-enhanced endorectal MR imaging prior to radical prostatectomy: experienced versus less experienced readersJurgen J Futterer
Department of Radiology, University Medical Center Nijmegen, The Netherlands
Radiology 237:541-9. 2005....
Prostate cancer: precision of integrating functional MR imaging with radiation therapy treatment by using fiducial gold markersHenkjan J Huisman
Department of Radiology, Radboud University Nijmegen Medical Center, Geert Grooteplein zuid 10, NL 6500 HB, Nijmegen, Netherlands
Radiology 236:311-7. 2005..01) than that of the landmark method (2.0 mm). Furthermore, a method is described by which multimodal MR imaging data are reduced into a single interpreted volume that, after registration, can be incorporated into treatment planning...
Vascular endothelial growth factor-A determines detectability of experimental melanoma brain metastasis in GD-DTPA-enhanced MRIWilliam Leenders
Department of Pathology, University Medical Centre St Radboud, Nijmegen, The Netherlands
Int J Cancer 105:437-43. 2003....
Local staging of prostate cancer using magnetic resonance imaging: a meta-analysisMarc R Engelbrecht
Department of Radiology, University Hospital Nijmegen, P O Box 9101, 6500 HB, Nijmegen, The Netherlands
Eur Radiol 12:2294-302. 2002..Our results suggest that turbo spin echo, endorectal coil, and multiple imaging planes improve staging performance. Studies with small sample sizes may result in higher staging performance...
Magnetic resonance tracking of dendritic cells in melanoma patients for monitoring of cellular therapyI Jolanda M de Vries
Department of Tumor Immunology, Radboud University Nijmegen Medical Center and Nijmegen Center for Molecular Life Sciences, Geert Grooteplein 28, 6500 HB Nijmegen, The Netherlands
Nat Biotechnol 23:1407-13. 2005..MRI cell tracking using iron oxides appears clinically safe and well suited to monitor cellular therapy in humans...
Discriminating cancer from noncancer tissue in the prostate by 3-dimensional proton magnetic resonance spectroscopic imaging: a prospective multicenter validation studyTom W J Scheenen
Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen, Netherlands
Invest Radiol 46:25-33. 2011....
Computerized three-dimensional localization of prostate cancer using contrast-enhanced power Doppler and clustering analysisHilco van Moerkerk
Department of Urology, Radboud University Medical Center Nijmegen, Nijmegen, The Netherlands
Eur Urol 50:762-8; discussion 768-9. 2006..03. CONCLUSION: Semiautomatic localization based on clustering analysis of blood flow aids in localization of prostate tumors. A clustering map is an easy-to-interpret extension to standard power Doppler images...
Cardiac-synchronized gadolinium-enhanced MR angiography: preliminary experience for the evaluation of the thoracic aortaJames W Goldfarb
Department of Cardiothoracic Surgery, University Hospital Nijmegen, Nijmegen 6564BM, Netherlands
Magn Reson Imaging 24:241-8. 2006..Synchronized imaging showed significantly better aortic valve leaflet and proximal coronary artery depiction. Synchronization reduced motion artifacts, allowing better visualization of the aortic root and proximal coronary arteries...
MR lymphangiography for detection of minimal nodal disease in patients with prostate cancerMukesh G Harisinghani
Department of Abdominal Imaging, Massachusetts General Hospital, Boston 02114, USA
Acad Radiol 9:S312-3. 2002
Gadobenate dimeglumine-enhanced MR angiography of the abdominal aorta and renal arteriesThomas J Kroencke
Department of Radiology, , , , Schumannstr. 20/21, 10098 Berlin, Germany
AJR Am J Roentgenol 179:1573-82. 2002..CONCLUSION: Gadobenate dimeglumine is an effective and safe agent for contrast-enhanced MR angiography of the abdominal aorta and renal arteries. A dose of 0.1 mmol/kg of body weight appears to be the most suitable...
Gadobenate dimeglumine-enhanced magnetic resonance angiography of the pelvic arteriesJohan Wikstrom
Department of Diagnostic Radiology, Uppsala University Hospital, Uppsala, Sweden
Invest Radiol 38:504-15. 2003..To evaluate 4 doses of gadobenate dimeglumine (Gd-BOPTA) for contrast-enhanced magnetic resonance angiography (CE-MRA) of the pelvic arteries and to compare CE-MRA with unenhanced time-of-flight MRA (2D-TOF-MRA)...
The value of single-shot black-blood MR imaging for mapping of the coronary arteries: a comparison of four different orientations during breath-holding and free breathingAgnes E Holland
Department of Radiology, University Hospital Nijmegen, The, Nijmegen, Netherlands
Magn Reson Imaging 20:261-9. 2002..The LAO orientation provides the most consistent visualization of the origins and major coronary artery segments...
Initial clinical experience with oral manganese (CMC-001) for liver MR imagingHenrik S Thomsen
Department of Diagnostic Radiology 54E2, Copenhagen University Hospital at Herlev, Herlev Ringvej 75, DK 2730 Herlev, Denmark
Eur Radiol 17:273-8. 2007..In patients without biliary tract obstruction, the biliary system is easily visualized. Oral manganese seems to be useful in hepatobiliary MRI. Further research is strongly warranted...
