Carel W E van Eijk

Summary

Affiliation: Delft University of Technology
Country: The Netherlands

Publications

  1. ncbi request reprint Inorganic scintillators in medical imaging
    Carel W E van Eijk
    Delft University of Technology, Iri, Radiation Technology, The Netherlands
    Phys Med Biol 47:R85-106. 2002
  2. ncbi request reprint Neutron detection and neutron dosimetry
    C W E van Eijk
    Delft University of Technology, Interfaculty Reactor Institute, Radiation Technology Group, Mekelweg 15, 2629 JB Delft, The Netherlands
    Radiat Prot Dosimetry 110:5-13. 2004
  3. doi request reprint Radiation detector developments in medical applications: inorganic scintillators in positron emission tomography
    Carel W E van Eijk
    Radiation Detection and Matter, R3, Faculty of Applied Sciences, Delft University of Technology, Mekelweg 15, 2629 JB Delft, The Netherlands
    Radiat Prot Dosimetry 129:13-21. 2008
  4. doi request reprint Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction
    Marnix C Maas
    Delft University of Technology, Mekelweg 15, 2629 JB Delft, The Netherlands
    Phys Med Biol 54:1893-908. 2009
  5. ncbi request reprint Model of the point spread function of monolithic scintillator PET detectors for perpendicular incidence
    Marnix C Maas
    Delft University of Technology, Mekelweg 15, 2629 JB Delft, The Netherlands
    Med Phys 37:1904-13. 2010

Collaborators

  • Dennis R Schaart
  • Marnix C Maas
  • Cedric LemaĆ®tre
  • Freek J Beekman
  • Peter Bruyndonckx
  • D J van der Laan
  • D J Jan van der Laan

Detail Information

Publications5

  1. ncbi request reprint Inorganic scintillators in medical imaging
    Carel W E van Eijk
    Delft University of Technology, Iri, Radiation Technology, The Netherlands
    Phys Med Biol 47:R85-106. 2002
    ..A review of medical diagnostic imaging methods utilizing x-rays or gamma rays and the application and development of inorganic scintillators is presented...
  2. ncbi request reprint Neutron detection and neutron dosimetry
    C W E van Eijk
    Delft University of Technology, Interfaculty Reactor Institute, Radiation Technology Group, Mekelweg 15, 2629 JB Delft, The Netherlands
    Radiat Prot Dosimetry 110:5-13. 2004
    ..Furthermore some recent developments in the field of fast-neutron dosimetry will be discussed...
  3. doi request reprint Radiation detector developments in medical applications: inorganic scintillators in positron emission tomography
    Carel W E van Eijk
    Radiation Detection and Matter, R3, Faculty of Applied Sciences, Delft University of Technology, Mekelweg 15, 2629 JB Delft, The Netherlands
    Radiat Prot Dosimetry 129:13-21. 2008
    ..The new scintillators show great promise for new developments in medical applications, in particular, for PET systems...
  4. doi request reprint Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction
    Marnix C Maas
    Delft University of Technology, Mekelweg 15, 2629 JB Delft, The Netherlands
    Phys Med Biol 54:1893-908. 2009
    ..8 ns FWHM. The good spatial, energy and timing resolutions, together with the excellent DOI correction and high detection efficiency of our detectors, are expected to facilitate high and uniform PET system resolution...
  5. ncbi request reprint Model of the point spread function of monolithic scintillator PET detectors for perpendicular incidence
    Marnix C Maas
    Delft University of Technology, Mekelweg 15, 2629 JB Delft, The Netherlands
    Med Phys 37:1904-13. 2010
    ..Here we develop, validate, and demonstrate a simple model of the detector point spread function (PSF) of such monolithic scintillator detectors...