L Lindborg

Summary

Affiliation: Swedish Radiation Protection Authority
Country: Sweden

Publications

  1. ncbi request reprint The response of the sievert instrument in neutron beams up to 180 MeV
    J E Kyllonen
    Swedish Radiation Protection Institute, S 171 16 Stockholm, Sweden
    Radiat Prot Dosimetry 94:227-32. 2001
  2. ncbi request reprint Cosmic radiation measurements on-board aircraft with the variance method
    J E Kyllonen
    Swedish Radiation Protection Institute, S 171 16 Stockholm, Sweden
    Radiat Prot Dosimetry 93:197-205. 2001
  3. ncbi request reprint Response investigations of a TEPC in high energy proton and neutron beams using the variance method
    J E Kyllonen
    Swedish Radiation Protection Authority, SE 171 16 Stockholm, Sweden
    Radiat Prot Dosimetry 99:373-4. 2002
  4. ncbi request reprint Photon and neutron dose discrimination using low pressure proportional counters with graphite and A150 walls
    J Kyllonen
    Swedish Radiation Protection Authority, SE 171 16 Stockholm, Sweden
    Radiat Prot Dosimetry 125:314-7. 2007
  5. ncbi request reprint Nanodosimetric measurements and calculations in a neutron therapy beam
    J E Grindborg
    Swedish Radiation Protection Authority, Stockholm, Sweden
    Radiat Prot Dosimetry 126:463-6. 2007
  6. ncbi request reprint Determinations of H(10) and its dose components onboard aircraft
    L Lindborg
    SSI Swedish Radiation Protection Authority, SE 17116 Stockholm, Sweden
    Radiat Prot Dosimetry 126:577-80. 2007
  7. ncbi request reprint Nanodosimetry in a clinical neutron therapy beam using the variance-covariance method and Monte Carlo simulations
    J E Lillhök
    Swedish Radiation Protection Authority, Stockholm, Sweden
    Phys Med Biol 52:4953-66. 2007
  8. ncbi request reprint Achievements in workplace neutron dosimetry in the last decade: lessons learned from the EVIDOS project
    R J Tanner
    Radiation Protection Division, Health Protection Agency, Chilton, Didcot OX11 0RQ, UK
    Radiat Prot Dosimetry 126:471-6. 2007
  9. ncbi request reprint Neutron area survey instrument measurements in the EVIDOS project
    R J Tanner
    Radiation Protection Division, Health Protection Agency, Chilton, Didcot OX11 0RQ, UK
    Radiat Prot Dosimetry 125:300-3. 2007
  10. ncbi request reprint Characterisation of mixed neutron photon workplace fields at nuclear facilities by spectrometry (energy and direction) within the EVIDOS project
    M Luszik-Bhadra
    Physikalisch Technische Bundesanstalt, Bundesallee 100, D 38116 Braunschweig, Germany
    Radiat Prot Dosimetry 124:219-29. 2007

Detail Information

Publications20

  1. ncbi request reprint The response of the sievert instrument in neutron beams up to 180 MeV
    J E Kyllonen
    Swedish Radiation Protection Institute, S 171 16 Stockholm, Sweden
    Radiat Prot Dosimetry 94:227-32. 2001
    ..Build-up measurements show that wall thickness is not crucial for H* determinations at 60 and 180 MeV...
  2. ncbi request reprint Cosmic radiation measurements on-board aircraft with the variance method
    J E Kyllonen
    Swedish Radiation Protection Institute, S 171 16 Stockholm, Sweden
    Radiat Prot Dosimetry 93:197-205. 2001
    ..No covariance is observed on any flight indicating it is sufficient to base dose determinations on variance measurements with only one detector. The uncertainties involved are also discussed in some detail...
  3. ncbi request reprint Response investigations of a TEPC in high energy proton and neutron beams using the variance method
    J E Kyllonen
    Swedish Radiation Protection Authority, SE 171 16 Stockholm, Sweden
    Radiat Prot Dosimetry 99:373-4. 2002
    ..Svedberg Laboratory in Uppsala are presented. The result indicate that a TEPC might underestimate the high-energy contribution to H*(10) in cosmic radiation applications such as measurements onboard aircraft...
  4. ncbi request reprint Photon and neutron dose discrimination using low pressure proportional counters with graphite and A150 walls
    J Kyllonen
    Swedish Radiation Protection Authority, SE 171 16 Stockholm, Sweden
    Radiat Prot Dosimetry 125:314-7. 2007
    ..The experimental data were obtained in measurement campaigns organised within the EVIDOS-project...
  5. ncbi request reprint Nanodosimetric measurements and calculations in a neutron therapy beam
    J E Grindborg
    Swedish Radiation Protection Authority, Stockholm, Sweden
    Radiat Prot Dosimetry 126:463-6. 2007
    ..The latter being larger than earlier reported result. Below 50 nm, the experimental values increase while the calculated decrease...
  6. ncbi request reprint Determinations of H(10) and its dose components onboard aircraft
    L Lindborg
    SSI Swedish Radiation Protection Authority, SE 17116 Stockholm, Sweden
    Radiat Prot Dosimetry 126:577-80. 2007
    ..The measured high-LET component and the calculated neutron component are not quite identical, but should be similar. The agreement was always within 20%. The high-LET component contributed with about 57% at N57 E8 and 48% at N42 E12...
  7. ncbi request reprint Nanodosimetry in a clinical neutron therapy beam using the variance-covariance method and Monte Carlo simulations
    J E Lillhök
    Swedish Radiation Protection Authority, Stockholm, Sweden
    Phys Med Biol 52:4953-66. 2007
    ..In line with previously reported results, the dose-mean lineal energy determined at 10 nm was shown to be related to clinical RBE values in the neutron beam and in a simulated 175 MeV proton beam as well...
  8. ncbi request reprint Achievements in workplace neutron dosimetry in the last decade: lessons learned from the EVIDOS project
    R J Tanner
    Radiation Protection Division, Health Protection Agency, Chilton, Didcot OX11 0RQ, UK
    Radiat Prot Dosimetry 126:471-6. 2007
    ....
  9. ncbi request reprint Neutron area survey instrument measurements in the EVIDOS project
    R J Tanner
    Radiation Protection Division, Health Protection Agency, Chilton, Didcot OX11 0RQ, UK
    Radiat Prot Dosimetry 125:300-3. 2007
    ..Additionally, since the response of these instruments is in some cases very well characterised, their systematic deviations from the reference quantities provide an important verification of the determination of those quantities...
  10. ncbi request reprint Characterisation of mixed neutron photon workplace fields at nuclear facilities by spectrometry (energy and direction) within the EVIDOS project
    M Luszik-Bhadra
    Physikalisch Technische Bundesanstalt, Bundesallee 100, D 38116 Braunschweig, Germany
    Radiat Prot Dosimetry 124:219-29. 2007
    ..The implication of the results for the determination of reference values for radiation protection quantities (ambient dose equivalent, personal dose equivalent and effective dose) and the related uncertainties are discussed...
  11. ncbi request reprint Evaluation of individual dosimetry in mixed neutron and photon radiation fields (EVIDOS). Part I: Scope and methods of the project
    F D'ERRICO
    Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione, Universita di Pisa, I 56126 Pisa, Italy
    Radiat Prot Dosimetry 125:275-80. 2007
    ..The results were collected in a large, searchable database and are intended to be used in the harmonisation of dosimetric procedures for mixed radiation fields and for the approval of dosimetry services in Europe...
  12. ncbi request reprint Summary of personal neutron dosemeter results obtained within the EVIDOS project
    M Luszik-Bhadra
    Physikalisch Technische Bundesanstalt, D 38116 Braunschweig, Germany
    Radiat Prot Dosimetry 125:293-9. 2007
    ..Under- and over-readings by more than a factor of two for the same dosemeter in different workplace fields indicate that in most cases the use of field-specific correction factors is required...
  13. ncbi request reprint Direction distributions of neutrons and reference values of the personal dose equivalent in workplace fields
    M Luszik-Bhadra
    Physikalisch Technische Bundesanstalt, D 38116 Braunschweig, Germany
    Radiat Prot Dosimetry 125:364-8. 2007
    ..e., at Krümmel (boiling water reactor and transport cask), at Mol (Venus research reactor and fuel facility Belgonucléaire) and at Ringhals (pressurised reactor and transport cask) are presented...
  14. ncbi request reprint Evaluation of individual dosimetry in mixed neutron and photon radiation fields (EVIDOS). Part II: Conclusions and recommendations
    H Schuhmacher
    Physikalisch Technische Bundesanstalt, D 38116 Braunschweig, Germany
    Radiat Prot Dosimetry 125:281-4. 2007
    ..Conclusions and recommendations are given concerning characterisation of radiation fields, methods to derive radiation protection quantities and dosemeter results...
  15. ncbi request reprint Evaluation of individual monitoring in mixed neutron/photon fields: mid-term results from the EVIDOS project
    F Vanhavere
    Studiecentrum voor Kernenergie Centre d étude de l énergie nucléaire, B 2400 Mol, Belgium
    Radiat Prot Dosimetry 120:263-7. 2006
    ..This paper will give an overview and some new results from the third campaign that was held in Mol (Belgium), around the research reactor VENUS and in the MOX producing plant of Belgonucléaire...
  16. ncbi request reprint Electronic neutron personal dosemeters: their performance in mixed radiation fields in nuclear power plants
    M Luszik-Bhadra
    Physikalisch Technische Bundesanstalt, D 38116 Braunschweig, Germany
    Radiat Prot Dosimetry 120:378-82. 2006
    ....
  17. ncbi request reprint Individual neutron monitoring in workplaces with mixed neutron/photon radiation
    T Bolognese-Milsztajn
    Institut de Radioprotection et de Surete Nucleaire, F 92265 Fontenay aux Roses, France
    Radiat Prot Dosimetry 110:753-8. 2004
    ....
  18. ncbi request reprint Exposure of aircraft crew to cosmic radiation: on-board intercomparison of various dosemeters
    J F Bottollier-Depois
    Institute for Radiological Protection and Nuclear Safety, IRSN, France
    Radiat Prot Dosimetry 110:411-5. 2004
    ..The agreement of values obtained for the total dose obtained by measurements and by calculations is very satisfying...
  19. ncbi request reprint Recent studies on the exposure of aircrew to cosmic and solar radiation
    D O'Sullivan
    Dublin Institute for Advanced Studies, Ireland
    Radiat Prot Dosimetry 100:495-8. 2002
    ..world data for a whole solar cycle will be more complete than ever before. Results indicate that for most routes investigated during solar minimum, aircrew are unlikely to receive doses in excess of 6 mSv.y(-1)...
  20. ncbi request reprint Application of workplace correction factors to dosemeter results for the assessment of personal doses at nuclear facilities
    L Lindborg
    Karolinska Institutet, Department of Medical Radiation Physics, SE 171 76 Stockholm, Sweden
    Radiat Prot Dosimetry 124:213-8. 2007
    ..5-1.5. Those conclusions are derived from results reported within the EC supported EVIDOS contract...