Intraocular lens to correct corneal comaJuan Tabernero
Laboratorio de Optica, Departamento de Fisica, Universidad de Murcia, Campus de Espinardo, Murcia, Spain
Opt Lett 32:406-8. 2007..This lens is designed to mimic the situation naturally occurring in the normal healthy eye. The new proposed IOL provides an improved optical quality for all lens powers...
Night myopia studied with an adaptive optics visual analyzerPablo Artal
Laboratorio de Optica, Universidad de Murcia, Murcia, Spain
PLoS ONE 7:e40239. 2012..However, despite its general acceptance, its magnitude and causes are still controversial. A series of experiments were performed to understand night myopia in greater detail...
Corneal optical aberrations and retinal image quality in patients in whom monofocal intraocular lenses were implantedAntonio Guirao
Laboratorio de Optica, Departamento de Fisica, Universidad de Murcia, Campus de Espinardo Edificio C, 30071 Murcia, Spain
Arch Ophthalmol 120:1143-51. 2002....
Adaptive optics for vision: the eye's adaptation to point spread functionPablo Artal
Laboratorio de Optica, Departamento de Fisica, Universidad de Murcia, Campus de Espinardo Edificio C, 30071 Murcia, Spain
J Refract Surg 19:S585-7. 2003..We used adaptive optics techniques to control the eye's aberrations in order to evaluate this hypothesis...
Visual effect of the combined correction of spherical and longitudinal chromatic aberrationsPablo Artal
Laboratorio de Optica, Centro de Investigación en Óptica y Nanofísica CiOyN, Universidad de Murcia, Campus de Espinardo, Murcia, Spain
Opt Express 18:1637-48. 2010..This suggests that an aspheric achromatic IOL may provide some visual benefit when compared to standard IOLs...
Are optical aberrations during accommodation a significant problem for refractive surgery?Pablo Artal
Departamento de Física Universidad de Murcia, Spain
J Refract Surg 18:S563-6. 2002..Those results were used in computer simulations to predict the benefit of a perfect customized correction...
Neural compensation for the eye's optical aberrationsPablo Artal
Laboratorio de Optica, Departamento de Fisica, Universidad de Murcia, Campus de Espinardo, Murcia, Spain
J Vis 4:281-7. 2004....
Optics of human eye: 400 years of exploration from Galileo's timePablo Artal
Laboratorio de Optica, Centro de Investigación en Optica y Nanofísica, Universidad de Murcia, Campus de Espinardo, 30071 Murcia, Spain
Appl Opt 49:D123-30. 2010..In the past decade, the use of wavefront sensing technology allowed us to complete our understating of eye optics as a robust aplanatic system...
An objective scatter index based on double-pass retinal images of a point source to classify cataractsPablo Artal
Laboratorio de Optica, Universidad de Murcia, Murcia, Spain
PLoS ONE 6:e16823. 2011..To propose a new objective scatter index (OSI) based in the analysis of double-pass images of a point source to rank and classify cataract patients. This classification scheme is compared with a current subjective system...
Contribution of the cornea and internal surfaces to the change of ocular aberrations with agePablo Artal
Laboratorio de Optica, Departamento de Fisica, Universidad de Murcia, Spain
J Opt Soc Am A Opt Image Sci Vis 19:137-43. 2002..These results suggest that the degradation of the ocular optics with age can be explained largely by the loss of the balance between the aberrations of the corneal and the internal surfaces...
The human eye is an example of robust optical designPablo Artal
Departamento de Fisica, Universidad de Murcia, Campus de Espinardo, Murcia, Spain
J Vis 6:1-7. 2006..These results may suggest the presence of an auto-compensation mechanism that renders the eye's optics robust despite large variation in the ocular shape and geometry...
Compensation of corneal aberrations by the internal optics in the human eyeP Artal
Laboratorio de Optica, Universidad de Murcia, Campus de Espinardo Edificio C, 30071 Murcia, Spain
J Vis 1:1-8. 2001..For example, it shows the limitation of corneal topography as a guide for new refractive procedures and provides a strong endorsement of the value of ocular wave-front sensing for those applications...
Binocular adaptive optics visual simulatorEnrique J Fernandez
Laboratorio de Optica, Centro de Investigación en Óptica y Nanofísica CiOyN, Universidad de Murcia, Campus de Espinardo, 30071 Murcia, Spain
Opt Lett 34:2628-30. 2009..The technique and the instrument might contribute to the better understanding of binocular vision and to the search for optimized ophthalmic corrections...
Optical aberrations of the human cornea as a function of ageA Guirao
Laboratorio de Optica, Universidad de Murcia, Spain
J Opt Soc Am A Opt Image Sci Vis 17:1697-702. 2000....
Wavefront optimized nonlinear microscopy of ex vivo human retinasEmilio J Gualda
Universidad de Murcia, Laboratorio de Optica, Campus de Espinardo CiOyN, Murcia, 30100 Spain
J Biomed Opt 15:026007. 2010..In particular, this may be important to study the physiology and function of the healthy and diseased retina...
Optical quality of the eye in subjects with normal and excellent visual acuityEloy A Villegas
Departamento de Fisica, Laboratorio de Optica, Universidad de Murcia, Murcia, Spain
Invest Ophthalmol Vis Sci 49:4688-96. 2008..VA ranged from decimal values of 1.0 (20/20) to 2.0 (20/10) when defocus and astigmatism were carefully corrected...
Functional optical zone of the corneaJuan Tabernero
Laboratorio de Optica Departmento Fisica, Universidad de Murcia, Murcia, Spain
Invest Ophthalmol Vis Sci 48:1053-60. 2007..The size of the treated area that has achieved good optical performance has been defined as the functional optical zone (FOZ). In this study the authors developed three objective methods to measure the FOZ...
Adaptive optics visual simulatorEnrique J Fernandez
Departamento de Fisica, Universidad de Murcia, Spain
J Refract Surg 18:S634-8. 2002..This "aberration testing station" or "visual simulator" allows us to study the relationship between specific aberrations and visual quality...
Predicting the optical performance of eyes implanted with IOLs to correct spherical aberrationJuan Tabernero
Laboratorio de Optica, , Universidad de Murcia, Murcia, Spain
Invest Ophthalmol Vis Sci 47:4651-8. 2006..This approach is quite powerful and is especially applicable to the study of current and future aberration-correction IOL designs...
Ocular aberrations up to the infrared range: from 632.8 to 1070 nmEnrique J Fernandez
Laboratorio de Optica, Universidad de Murcia, Centro de Investigación en Optica y Nanotecnología, Campus de Espinardo, 30071 Murcia, Spain
Opt Express 16:21199-208. 2008..It allows for measuring and controlling aberrations whilst the subject might eventually perform visual tests, with no interference from the beacon light...
Mechanism of compensation of aberrations in the human eyeJuan Tabernero
Laboratorio de Optica, Departamento de Fisica, Universidad de Murcia, Campus de Espinardo, Edificio CiOyN, 30071 Murcia, Spain
J Opt Soc Am A Opt Image Sci Vis 24:3274-83. 2007..We showed that the eye behaves as an aplanatic optical system, an optimized design solution rendering stable retinal image quality for different ocular geometries...
Purkinje imaging system to measure anterior segment scattering in the human eyeJuan M Bueno
Laboratorio de Optica, Centro de Investigación en Optica y Nanofísica, Universidad de Murcia, Spain
Opt Lett 32:3447-9. 2007..The future use of this technique in clinical environments might help to estimate the level of corneal haze in eyes undergoing refractive surgery or/and scattering within the lens during cataract development...
Peripheral optical errors and their change with accommodation differ between emmetropic and myopic eyesLinda Lundström
Laboratorio de Optica, Departamento de Fisica, Universidad de Murcia, Campus de Espinardo, Murcia, Spain
J Vis 9:17.1-11. 2009..These findings may indicate a difference between emmetropic and myopic eyes that could be an important clue to understand myopia progression...
Laser in situ keratomileusis disrupts the aberration compensation mechanism of the human eyeAntonio Benito
Departamento de Fisica, Universidad de Murcia, Spain
Am J Ophthalmol 147:424-431.e1. 2009..To study how changes induced on corneal optics by myopic and hyperopic laser in situ keratomileusis (LASIK) refractive surgery affect the aberration compensation mechanism...
Adaptive optics multiphoton microscopy to study ex vivo ocular tissuesJuan M Bueno
Universidad de Murcia, Laboratorio de Óptica, Campus de Espinardo, Murcia, 30100 Spain
J Biomed Opt 15:066004. 2010..This instrument might be useful to explore the possible connections between changes in ocular structures and the associated pathologies...
Wave-aberration control with a liquid crystal on silicon (LCOS) spatial phase modulatorEnrique J Fernandez
Centro de Investigación en Optica y Nanofísica, Universidad de Murcia, Campus de Espinardo, Murcia, Spain
Opt Express 17:11013-25. 2009..The results are particularly important for visual simulation and ophthalmic testing applications, although they are equally interesting for any adaptive optics application with liquid crystal based devices...
Optical characterization of Bangerter foilsGuillermo M Pérez
Laboratorio de Optica, Departamento de Fisica, Universidad de Murcia, Murcia, Spain
Invest Ophthalmol Vis Sci 51:609-13. 2010..The authors examined the optical properties of Bangerter foils and compared them with the effect of defocus...
Wavefront measurements of phase plates combining a point-diffraction interferometer and a Hartmann-Shack sensorJuan M Bueno
Laboratorio de Optica, , Universidad de Murcia, Campus de Espinardo, 30100 Murcia, Spain
Appl Opt 49:450-6. 2010..The combination of the two techniques can accurately measure complicated phase profiles, combining the robustness of the HS and the higher resolution and dynamic range of the PDI...
Impact of scattering and spherical aberration in contrast sensitivityGuillermo M Pérez
Laboratorio de Optica, Departamento de Fisica, Universidad de Murcia, Campus de Espinardo, Edificio CiOyN, Murcia, Spain
J Vis 9:19.1-10. 2009..This is actually the situation in older eyes with both spherical aberration and intraocular scatter being higher than in young eyes...
Visual acuity and optical parameters in progressive-power lensesEloy A Villegas
Laboratorio de Optica, Department de Física, Universidad de Murcia, Murcia, Spain
Optom Vis Sci 83:672-81. 2006..The purposes of this study are to explore the effect of astigmatism and high-order aberrations of progressive-power lenses (PPLs) on visual acuity (VA) and to find a good optical metric for evaluating visual performance of PPLs...
An analytical model describing aberrations in the progression corridor of progressive addition lensesRalf Blendowske
Laboratorio de Optica, Universidad de Murcia, Murcia, Spain
Optom Vis Sci 83:666-71. 2006..Therefore, higher-order aberrations have a minimal impact on the optical performance of these lenses...
Comparison of aberrations in different types of progressive power lensesEloy A Villegas
Laboratorio de Optica, Departamento de Fisica, Universidad de Murcia, Campus de Espinardo Edificio C, Murcia, Spain
Ophthalmic Physiol Opt 24:419-26. 2004....
Aberro-polariscope for the human eyeJuan M Bueno
Laboratorio de Optica, Departamento de Fisica, Universidad de Murcia, Campus de Espinardo Edificio C, 30071 Murcia, Spain
Opt Lett 28:1209-11. 2003..This instrument allows useful information on both the optical and the biomechanical properties of the eye to be obtained...
Corneal aberrations before and after small-incision cataract surgeryAntonio Guirao
Departamento de Fisica, Universidad de Murcia, Campus de Espinardo, 30071 Murcia, Spain
Invest Ophthalmol Vis Sci 45:4312-9. 2004..To study the effect of small-incision cataract surgery on the optical aberrations of the cornea...
Spatially resolved wavefront aberrations of ophthalmic progressive-power lenses in normal viewing conditionsEloy A Villegas
Laboratorio de Optica, Dept de Fisica, Universidad de Murcia, Campus de Espinardo, Murcia, Spain
Optom Vis Sci 80:106-14. 2003..To measure the wavefront aberration at different locations in progressive-power lenses (PPL's) isolated and in situ (PPL's plus eye)...
Study on the effects of monochromatic aberrations in the accommodation response by using adaptive opticsEnrique J Fernandez
Laboratorio de Optica, Departamento de Fisica, Universidad de Murcia, Campus de Espinardo Edificio C, 30071 Murcia, Spain
J Opt Soc Am A Opt Image Sci Vis 22:1732-8. 2005..However, neither the latency time nor the precision of the accommodation were affected. These results may indicate that the monochromatic aberrations play a role in driving the accommodation response...
Aberration generation by contact lenses with aspheric and asymmetric surfacesNorberto Lopez-Gil
Laboratorio de Optica, Universidad de Murcia, Spain
J Refract Surg 18:S603-9. 2002..We explored the potential of aberration correction in the human eye by using a new generation of soft contact lenses with aspheric and asymmetric surfaces...
Optical aberrations and the aging eyePablo Artal
Departmento de Fisica, Universidad de Murcia, Spain
Int Ophthalmol Clin 43:63-77. 2003
Directional imaging of the retinal cone mosaicBrian Vohnsen
Laboratorio de Optica, Universidad de Murcia, Campus de Espinardo Edificio C, 30071 Murcia, Spain
Opt Lett 29:968-70. 2004..We discuss details of the system and describe cone-mosaic images obtained under different conditions...
Correlation between optical and psychophysical parameters as a function of defocusEloy A Villegas
Laboratorio de Optica, Departamento de Fisica, Universidad de Murcia, Campus de Espinardo, Murcia, Spain
Optom Vis Sci 79:60-7. 2002..To evaluate how ocular optical image quality and psychophysical estimates of visual performance compare to each other as a function of defocus...
Corneal polarimetry after LASIK refractive surgeryJuan M Bueno
Universidad de Murcia, Laboratorio de Optica, Campus de Espinardo Edificio C, 30071, Murcia, Spain
J Biomed Opt 11:014001. 2006....
Guided light and diffraction model of human-eye photoreceptorsBrian Vohnsen
Laboratorio de Optica, Universidad de Murcia, Campus de Espinardo Edificio C, 30071 Murcia, Spain
J Opt Soc Am A Opt Image Sci Vis 22:2318-28. 2005..We apply this knowledge to a detailed study of the relationship between the Stiles-Crawford effect and its optical counterpart...
Directional light scanning laser ophthalmoscopeBrian Vohnsen
Laboratorio de Optica, Universidad de Murcia, Campus de Espinardo Edificio C, 30071 Murcia, Spain
J Opt Soc Am A Opt Image Sci Vis 22:2606-12. 2005..Lett. 29, 968 (2004)] together with a detailed numerical analysis of the device. The outcome is compared with experimental results...
Temporal dynamics of ocular aberrations: monocular vs binocular visionA Mira-Agudelo
Laboratorio de Optica, Centro de Investigación en Óptica y Nanofísica CiOyN, Universidad de Murcia, Campus de Espinardo Murcia, Murcia 30100, Spain
Ophthalmic Physiol Opt 29:256-63. 2009..We did find differences in pupil size with mono- and binocular vision but the pupil size temporal dynamics did not behave in the same way as the aberrations' dynamics...
Optical modulation transfer and contrast sensitivity with decentered small pupils in the human eyeP Artal
Departamento de Fisica, Universidad de Murcia, Spain
Vision Res 36:3575-86. 1996..In conclusion, the combination of the ocular transverse chromatic aberration and monochromatic aberrations accounts for the loss in visual sensitivity found with a decentered small pupil at low and intermediate spatial frequencies...
A wavelength tunable wavefront sensor for the human eyeSilvestre Manzanera
Laboratorio de Optica, Universidad de Murcia LOUM, Centro de Investigación en Optica y Manofísica CiOyN, Campus de Espinardo, E 30071 Murcia, Spain
Opt Express 16:7748-55. 2008..To our knowledge, this is the first report of a device to objectively determine the spectral fluctuations in the ocular wavefront...
Wide-angle chromatic aberration corrector for the human eyeYael Benny
Laboratorio de Optica, Universidad de Murcia, Spain
J Opt Soc Am A Opt Image Sci Vis 24:1538-44. 2007..Measurements in real eyes were conducted to examine the level and optical quality of the correction. We also performed some tests to evaluate the effect of the corrector on visual performance...
Ocular wave-front aberration statistics in a normal young populationJosé Francisco Castejón-Mochón
Laboratorio de Optica, Departamento de Fisica, Universidad de Murcia, Campus de Espinardo, Edificio C, 30071, Murcia, Spain
Vision Res 42:1611-7. 2002..Comparison of wave-fronts aberrations from right and left eye in 35 subjects, showed a good correlation between most of the second- and third-order terms and a slight (but not clear) tendency for mirror symmetry between eyes...
Polarization and retinal image quality estimates in the human eyeJ M Bueno
Departamento de Fisica, Universidad de Murcia, Spain
J Opt Soc Am A Opt Image Sci Vis 18:489-96. 2001..However, quite different estimates of the retinal image quality are obtained for combinations of polarization states in both the first and the second passes in the double-pass apparatus...
Second-harmonic microscopy of ex vivo porcine corneasB Vohnsen
LOUM, CiOyN, Murcia University, 30071 Murcia, Spain
J Microsc 232:158-63. 2008..Such studies are essential first steps towards a future high-resolution optical characterization technique for simultaneous corneal surgery and wound healing of the human eye...
Cause of monocular diplopia diagnosed by combining double-pass retinal image assessment and Hartmann-Shack aberrometryGuillermo M Pérez
Departamento de Fisica, Universidad de Murcia, Murcia, Spain
J Refract Surg 26:301-4. 2010..To report an advanced optical procedure developed for the diagnosis of a particular case of diplopia...
Theoretical comparison of aberration-correcting customized and aspheric intraocular lensesPatricia A Piers
AMO Groningen, The Netherlands
J Refract Surg 23:374-84. 2007..To assess the performance and optical limitations of standard, aspheric, and wavefront-customized intraocular lenses (IOLs) using clinically verified pseudophakic eye models...
Influence of Stiles-Crawford apodization on visual acuityDavid A Atchison
Centre for Eye Research, School of Optometry, Queensland University of Technology, Kelvin Grove, Australia
J Opt Soc Am A Opt Image Sci Vis 19:1073-83. 2002..The greatest influence on visual acuity of neutralizing the SCE, across the subjects and range of conditions, was deterioration of 0.06 (4-mm pupil), 0.16 (6-mm pupil), and 0.29 log unit (7.6-mm pupil)...
Use of adaptive optics to determine the optimal ocular spherical aberrationPatricia A Piers
Department of Applied Research, AMO Groningen BV, Groningen, The Netherlands
J Cataract Refract Surg 33:1721-6. 2007..To explore the impact of spherical aberration (SA) on contrast sensitivity using an adaptive optics vision simulator to determine the optimal amount of SA to include in customized corrections of wavefront aberrations...
Optical Quality Analysis System; Instrument for objective clinical evaluation of ocular optical qualityJosé L Güell
J Cataract Refract Surg 30:1598-9. 2004
Neural compensation for the best aberration correctionLi Chen
Center for Visual Science, University of Rochester, Rochester, NY, USA
J Vis 7:9.1-9. 2007..Neural adaptation slightly modifies the best aberration correction, although this effect averaged only approximately 12% of complete adaptation. These results may have practical consequences for customized vision correction...
Peripheral refractive errors in myopic, emmetropic, and hyperopic young subjectsAnne Seidemann
University Eye Hospital, Section of Neurobiology of the Eye, Calwerstrasse 7/1, , Germany
J Opt Soc Am A Opt Image Sci Vis 19:2363-73. 2002..The finding of general peripheral myopia was unexpected. Its possible roles in foveal refractive development are discussed...
Adaptive optics simulation of intraocular lenses with modified spherical aberrationPatricia A Piers
AMO Groningen, Groningen, P O Box 901, 9700 AX Groningen, The Netherlands
Invest Ophthalmol Vis Sci 45:4601-10. 2004..In this study, adaptive optics techniques were used to evaluate the potential advantages and disadvantages associated with intraocular lenses (IOLs) with modified spherical aberration profiles...
Comparison of the retinal image quality with a Hartmann-Shack wavefront sensor and a double-pass instrumentFernando Diaz-Douton
Centre de Desenvolupament de Sensors, Instrumentació i Sistemes, Universidad Politécnica de Cataluña, Terrassa, Spain
Invest Ophthalmol Vis Sci 47:1710-6. 2006..This study showed that, in those cases, the double-pass technique is a complementary tool for better estimation of ocular optical quality...
Three-dimensional adaptive optics ultrahigh-resolution optical coherence tomography using a liquid crystal spatial light modulatorEnrique J Fernandez
Center for Biomedical Engineering and Physics, Vienna University of Medicine, Austria
Vision Res 45:3432-44. 2005..Volumetric UHR OCT of the living retina, obtained with up 25,000A-scans/s and high resolution enables visualization of retinal features that might correspond to groups of terminal bars of photoreceptors at the external limiting membrane...