Research Topics
| Susana MarcosSummaryCountry: Spain Publications
| Collaborators
|
Detail Information
Publications
On the symmetry between eyes of wavefront aberration and cone directionalityS Marcos
Schepens Eye Research Institute, 20 Staniford Street, 02114, Boston, MA, USA
Vision Res 40:2437-47. 2000..Cone directionality apodization improves optical quality, but not optimally in all eyes, and it does not tend to increase symmetry in the optical performance of left and right eyes...
Increase in corneal asphericity after standard laser in situ keratomileusis for myopia is not inherent to the Munnerlyn algorithmSusana Marcos
Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
J Refract Surg 19:S592-6. 2003..This study tries to resolve this controversy and discusses causes of optical degradation after refractive surgery...
Balance of corneal horizontal coma by internal optics in eyes with intraocular artificial lenses: evidence of a passive mechanismSusana Marcos
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
Vision Res 48:70-9. 2008..Our results cannot exclude a fine-tuning for the orientation of the crystalline lens, since cataract surgery seems to preserve the position of the capsule...
Optical quality and depth-of-field of eyes implanted with spherical and aspheric intraocular lensesSusana Marcos
Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
J Refract Surg 21:223-35. 2005..To compare experimental optical performance in eyes implanted with spherical and aspheric intraocular lenses (IOLs)...
Influence of adaptive-optics ocular aberration correction on visual acuity at different luminances and contrast polaritiesSusana Marcos
Instituto de Optica, Consejo Superior de Investigaciones Cientificas, CSIC, Madrid, Spain
J Vis 8:1.1-12. 2008..The improved performance with WoB targets with respect to BoW targets is decreased when correcting aberrations, suggesting a role of ocular aberrations in the differences in visual performance between contrast polarities...
Are changes in ocular aberrations with age a significant problem for refractive surgery?Susana Marcos
Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
J Refract Surg 18:S572-8. 2002..Potential benefits of customized IOLs for cataract surgery and improved optics in older patients are discussed...
Optical response to LASIK surgery for myopia from total and corneal aberration measurementsS Marcos
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas CSIC, Serrano 121, Madrid 28006, Spain
Invest Ophthalmol Vis Sci 42:3349-56. 2001..To evaluate the optical aberrations induced by LASIK refractive surgery for myopia on the anterior surface of the cornea and the entire optical system of the eye...
Ocular aberrations with ray tracing and Shack-Hartmann wave-front sensors: does polarization play a role?Susana Marcos
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
J Opt Soc Am A Opt Image Sci Vis 19:1063-72. 2002..In addition, differences in the recorded aerial images due to changes in polarization do not affect the aberration measurements in these reflectometric aberrometers...
Investigating sources of variability of monochromatic and transverse chromatic aberrations across eyesS Marcos
Schepens Eye Research Institute, 20 Staniford Street, Boston, MA 02114, USA
Vision Res 41:3861-71. 2001..Our results suggest an important contribution of corneal irregularities to those aberrations...
Aberrations and visual performance following standard laser vision correctionS Marcos
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
J Refract Surg 17:S596-601. 2001..To relate the change of ocular aberrations with the change of visual performance produced by standard laser in situ keratomileusis (LASIK) for myopia...
Change in corneal aberrations after cataract surgery with 2 types of aspherical intraocular lensesSusana Marcos
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
J Cataract Refract Surg 33:217-26. 2007..To study the effect of cataract surgery through 3.2 mm superior incisions on corneal aberrations with 2 types of monofocal intraocular lenses (IOLs) with an aspherical design...
Experimental evaluation of optimized ablation patterns for laser refractive surgeryCarlos Dorronsoro
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, Serrano 121, 28006, Madrid, Spain
Opt Express 17:15292-307. 2009..These models have proved useful (1) to assess the outcomes of different lasers or ablation algorithms, (2) for precise calibration and testing of the lasers, and (3) to calculate experimental correction factors for efficiency effects...
Effect of sampling on real ocular aberration measurementsLourdes Llorente
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
J Opt Soc Am A Opt Image Sci Vis 24:2783-96. 2007..Experimentally, we did not find large differences across patterns except, as expected, for undersampled patterns...
Experimental simulation of simultaneous visionPablo de Gracia
Instituto de and Oacute
Invest Ophthalmol Vis Sci 54:415-22. 2013..To present and validate a prototype of an optical instrument that allows experimental simulation of pure bifocal vision. To evaluate the influence of different power additions on image contrast and visual acuity...
Myopic versus hyperopic eyes: axial length, corneal shape and optical aberrationsLourdes Llorente
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
J Vis 4:288-98. 2004..Our results may be indicative of presbyopic changes occurring earlier in hyperopes than in myopes...
Optical coherence tomography for quantitative surface topographySergio Ortiz
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, C Serrano 121, 28006 Madrid, Spain
Appl Opt 48:6708-15. 2009..With a proper calibration of the system with use of an onfocal channel, this algorithm makes it possible for time-domain OCT devices to be used as topographers...
Minor influence of myopic laser in situ keratomileusis on the posterior corneal surfaceAlfonso Pérez-Escudero
Instituto de Optica, Daza de Valdés, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
Invest Ophthalmol Vis Sci 50:4146-54. 2009..To check whether myopic LASIK induces changes on the posterior corneal surface...
Three-dimensional reconstruction of the crystalline lens gradient index distribution from OCT imagingAlberto de Castro
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, 121 Madrid 28006, Spain
Opt Express 18:21905-17. 2010..87 μm assuming a homogenous equivalent refractive index, and the presence of GRIN shifted the spherical aberration toward negative values (-0.97 μm), for a 6-mm pupil...
Analysis of the optical field on the human retina from wavefront aberration dataSergio Barbero
Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
J Opt Soc Am A Opt Image Sci Vis 25:2280-5. 2008..In addition, we have compared our results with those of the conventional procedure used to compute intensities on the retina. We have found significant differences between our results and the conventional ones...
Intraocular lens alignment from purkinje and Scheimpflug imagingPatricia Rosales
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
Clin Exp Optom 93:400-8. 2010..This reveals a relatively minor contribution of IOL tilt and decentration on the higher-order aberrations of the normal pseudophakic eye...
Comparison of real and computer-simulated outcomes of LASIK refractive surgeryDaniel Cano
, , Serrano 121, 28006 Madrid, Spain
J Opt Soc Am A Opt Image Sci Vis 21:926-36. 2004..Consideration of these effects with a parabolic pattern accounts for 70% of the clinical increase in asphericity...
Total and corneal optical aberrations induced by laser in situ keratomileusis for hyperopiaLourdes Llorente
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
J Refract Surg 20:203-16. 2004..To evaluate changes induced by standard laser in situ keratomileusis (LASIK) for hyperopia on total and corneal optical quality...
Aberrations of the human eye in visible and near infrared illuminationLourdes Llorente
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, Serrano, Madrid, Spain
Optom Vis Sci 80:26-35. 2003....
On-eye measurement of optical performance of rigid gas permeable contact lenses based on ocular and corneal aberrometryCarlos Dorronsoro
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
Optom Vis Sci 80:115-25. 2003..Our aim was to obtain a complete description of the interactions of rigid gas permeable (RGP) contact lenses with the optics of normal eyes...
Dependence of subjective image focus on the magnitude and pattern of high order aberrationsLucie Sawides
Instituto de Optica, Consejo Superior de Investigaciones Cientificas, CSIC, Madrid, Spain
J Vis 12:4. 2012..The representation of subjective image focus thus appears to be driven primarily by the overall amount of blur and only weakly by HOA blur orientation...
Corneal biomechanical properties from two-dimensional corneal flap extensiometry: application to UV-riboflavin cross-linkingSabine Kling
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
Invest Ophthalmol Vis Sci 53:5010-5. 2012..We developed a two-dimensional (2D) flap extensiometry technique, combining the advantages of both methods, and applied it to measure the effect of UV-Riboflavin cross-linking (CXL)...
Visual performance with real-life tasks under adaptive-optics ocular aberration correctionLucie Sawides
Instituto de Optica, Consejo Superior de Investigaciones Cientificas, CSIC, Madrid, Spain
J Vis 10:19. 2010..In all eyes (except one), AO correction improved familiar face recognition, by a factor of x1.13 +/- 0.12 on average. However, AO correction did not improve systematically facial expression recognition...
Corneal biomechanical changes after collagen cross-linking from porcine eye inflation experimentsSabine Kling
Instituto de Optica, Daza de Valdés, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
Invest Ophthalmol Vis Sci 51:3961-8. 2010..The authors studied the corneal response to variable intraocular pressure (IOP) in porcines eyes after UV collagen cross-linking (CXL), in comparison with untreated eyes...
Optical distortion correction in optical coherence tomography for quantitative ocular anterior segment by three-dimensional imagingSergio Ortiz
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, 28006 Madrid, Spain
Opt Express 18:2782-96. 2010..Optical distortion correction in 3-D is critical for quantitative analysis of OCT anterior segment imaging, and allows accurate topography of the internal surfaces of the eye...
Optical aberrations of intraocular lenses measured in vivo and in vitroSergio Barbero
Instituto de Optica, , Calle Serrano 121, 28006 Madrid, Spain
J Opt Soc Am A Opt Image Sci Vis 20:1841-51. 2003..Computer simulations and in vitro measurements show that tilts and decentrations might be contributors to the increased third-order aberrations in vivo in comparison with in vitro measurements...
Accuracy of the reconstruction of the crystalline lens gradient index with optimization methods from ray tracing and Optical Coherence Tomography dataAlberto de Castro
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, C Serrano 121, 28006 Madrid Spain
Opt Express 19:19265-79. 2011..OCT-based input data produced the most accurate GRIN reconstructions. We found that optimization methods (combining global and local search algorithms) allow GRIN reconstructions with acceptable accuracies for moderate noise level...
Double-pass measurement of retinal image quality in the chicken eyeNancy J Coletta
New England College of Optometry, Boston, Massachusetts 02115, USA
Optom Vis Sci 80:50-7. 2003..An objective double-pass technique was used to measure the optical quality of the eyes of White Leghorn chickens...
Phakometry and lens tilt and decentration using a custom-developed Purkinje imaging apparatus: validation and measurementsPatricia Rosales
Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
J Opt Soc Am A Opt Image Sci Vis 23:509-20. 2006..09 to -0.22 mm vertically. IOL tilt ranged from 3.6 to -1.51 deg horizontally and from 5.97 to -1.85 deg vertically. IOL decentration ranged from 0.53 to -0.31 mm horizontally and from 0.13 to -0.96 mm vertically...
Optical aberrations in the mouse eyeElena García de la Cera
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
Vision Res 46:2546-53. 2006..In this study, we measured the ocular aberrations in the wild type mouse...
Pentacam Scheimpflug quantitative imaging of the crystalline lens and intraocular lensPatricia Rosales
Institute de Optica Daza de Valdés, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
J Refract Surg 25:421-8. 2009..To implement geometrical and optical distortion correction methods for anterior segment Scheimpflug images obtained with a commercially available system (Pentacam, Oculus Optikgeräte GmbH)...
Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging. Validation studyAlberto de Castro
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
J Cataract Refract Surg 33:418-29. 2007..To measure tilt and decentration of intraocular lenses (IOLs) with Scheimpflug and Purkinje imaging systems in physical model eyes with known amounts of tilt and decentration and patients...
Design of isoplanatic aspheric monofocal intraocular lensesSergio Barbero
Instituto de Optica, Consejo Superior de Investigaciones Cientificas CSIC, Madrid, Spain
Opt Express 19:6215-30. 2011..Aspheric isoplanatic designs improve peripheral quality over current aspheric IOLs. Also, isoplanatic designs provide more stable optical quality across the field and across pupil diameter...
Accommodative lag and fluctuations when optical aberrations are manipulatedEnrique Gambra
Instituto de Optica, Consejo Superior de Investigaciones Cientificas CSIC, Madrid, Spain
J Vis 9:4.1-15. 2009..The study demonstrates that aberrations influence accommodative lag and fluctuations of accommodation and that correcting aberrations improves rather than compromises the accommodative response...
Perceptual adaptation to the correction of natural astigmatismMaria Vinas
Instituto de Optica, Consejo Superior de Investigaciones Cientificas CSIC, Madrid, Spain
PLoS ONE 7:e46361. 2012..We evaluated whether the perception of oriented blur is biased by the native astigmatism, and studied the time course of the after-effects following spectacle correction of astigmatism in habitually non-corrected astigmats...
Adaptation to astigmatic blurLucie Sawides
Instituto de Optica, Consejo Superior de Investigaciones Cientificas, CSIC, Madrid, Spain
J Vis 10:22. 2010..Our results suggest that strong selective adaptation can occur for different lower order aberrations of the eye and that these may be at least partly driven by the apparent figural changes that blurring introduces into the retinal image...
Combining coma with astigmatism can improve retinal image over astigmatism alonePablo de Gracia
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, Serrano 121, 28006, Madrid, Spain
Vision Res 50:2008-14. 2010..Nevertheless, in the presence of typical normal levels of HOA the effect of the coma/astigmatism interaction is considerably diminished...
Corneal and total optical aberrations in a unilateral aphakic patientSergio Barbero
Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
J Cataract Refract Surg 28:1594-600. 2002....
Full OCT anterior segment biometry: an application in cataract surgerySergio Ortiz
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, C Serrano 121, 28006 Madrid, Spain
Biomed Opt Express 4:387-96. 2013..47 deg superiorly), but slightly lower amounts (0.77 deg superiorly). The IOL was decentered superiorly (0.39 mm) and nasally (0.26 mm)...
In vivo human crystalline lens topographySergio Ortiz
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, C Serrano 121, 28006 Madrid, Spain
Biomed Opt Express 3:2471-88. 2012....
Vision is adapted to the natural level of blur present in the retinal imageLucie Sawides
Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
PLoS ONE 6:e27031. 2011..The image formed by the eye's optics is inherently blurred by aberrations specific to an individual's eyes. We examined how visual coding is adapted to the optical quality of the eye...
Dynamic OCT measurement of corneal deformation by an air puff in normal and cross-linked corneasCarlos Dorronsoro
Instituto de Optica, Consejo Superior de Investigaciones Cientificas CSIC, Serrano 121, 28006 Madrid, Spain
Biomed Opt Express 3:473-87. 2012....
Effect of air-flow on the evaluation of refractive surgery ablation patternsCarlos Dorronsoro
Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
Opt Express 19:4653-66. 2011..Shielding effects can be avoided by tuning the air flow to the laser repetition rate...
Suitability of Filofocon A and PMMA for experimental models in excimer laser ablation refractive surgeryCarlos Dorronsoro
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, Serrano 121, 28006, Madrid, Spain
Opt Express 16:20955-67. 2008....
Three-dimensional ray tracing on Delaunay-based reconstructed surfacesSergio Ortiz
, , C Serrano 121, 28006 Madrid, Spain
Appl Opt 48:3886-93. 2009..The method competes in flexibility, simplicity, and computing times with standard methods for surface fitting and ray tracing...
Crystalline lens radii of curvature from Purkinje and Scheimpflug imagingPatricia Rosales
Instituto de Optica, Daza de Valdés, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
J Vis 6:1057-67. 2006..Computer simulations using the Scheimpflug data as input show that the consistent slight overestimation of the posterior lens radius using Purkinje imaging can be partly attributed to the asphericity of the lens surface...
Changes in crystalline lens radii of curvature and lens tilt and decentration during dynamic accommodation in rhesus monkeysPatricia Rosales
Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
J Vis 8:18.1-12. 2008..147 +/- 0.25 deg/D. These results are important to fully characterize accommodation in rhesus monkeys...
Validation of the estimation of corneal aberrations from videokeratography in keratoconusSergio Barbero
Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
J Refract Surg 18:263-70. 2002..To validate the estimation of corneal aberrations from videokeratography against a laser ray tracing technique that measured total eye aberrations, in eyes without keratoconus (ie, cornea-dominated wave aberrations)...
Fluorescent labeling of Acanthamoeba assessed in situ from corneal sectioned microscopySusana Marcos
Instituto de Optica Daza de Valdes, Consejo Superior de Investigaciones Cientificas, C Serrano 121, 28006 Madrid, Spain
Biomed Opt Express 3:2489-99. 2012..Corneal confocal microscopy, provided with a fluorescent channel, could be largely improved in specificity and sensitivity in combination with specific fluorescent marking...
Imperfect optics may be the eye's defence against chromatic blurJames S McLellan
Schepens Eye Research Institute, 20 Staniford Street, Boston, Massachusetts 02114, USA
Nature 417:174-6. 2002....
Dynamic accommodation with simulated targets blurred with high order aberrationsEnrique Gambra
Instituto de Optica, Consejo Superior de Investigaciones Cientificas, Madrid, Spain
Vision Res 50:1922-7. 2010..We found a strong correlation between the relative accommodative gain (and phase lag) and the contrast degradation imposed on the target at relevant spatial frequencies...
Image quality of the human eyeSusana Marcos
Instituto de Optica, Consejo Superior ded Investigaciones Cientificas, Madrid, Spain
Int Ophthalmol Clin 43:43-62. 2003
Aberrometry: the past, present, and future of optometryLarry N Thibos
Optom Vis Sci 80:1-2. 2003
The influence of the Stiles-Crawford peak location on visual performanceDavid A Atchison
Centre for Eye Research, School of Optometry, Queensland University of Technology, Victoria Park Road, Kelvin Grove, 4059, QLD, Australia
Vision Res 43:659-68. 2003..The peak position had definite influence on performance, but this was mainly noticeable when subjects were defocused e.g. SM's visual acuity was reduced by 0.13 log units under the peak-shifted condition at -2D (hypermetropic) defocus...
Aberrometry: clinical and research applicationsRaymond A Applegate
Optom Vis Sci 80:85-6. 2003