A Llobera

Summary

Country: Spain

Publications

  1. doi request reprint PDMS based photonic lab-on-a-chip for the selective optical detection of heavy metal ions
    Bergoi Ibarlucea
    Instituto de Microelectronica de Barcelona, IMB CNM CSIC, Campus Universitat Autònoma de Barcelona, 08193, Bellaterra, Spain
    Analyst 138:839-44. 2013
  2. doi request reprint Fluorophore-doped xerogel antiresonant reflecting optical waveguides
    A Llobera
    Institut de Microelectrònica de Barcelona IMB CNM CSIC, Campus UAB 08193 Barcelona, Spain
    Opt Express 19:5026-39. 2011
  3. ncbi request reprint 3-D modulable PDMS-based microlens system
    V J Cadarso
    Institut de Microelectrònica de Barcelona IMB CNM CSIC, Campus UAB 08193 Barcelona, Spain
    Opt Express 16:4918-29. 2008
  4. doi request reprint Selective functionalisation of PDMS-based photonic lab on a chip for biosensing
    Bergoi Ibarlucea
    Instituto de Microelectronica de Barcelona, IMB CNM CSIC, Campus UAB, 08193 Bellaterra, Spain
    Analyst 136:3496-502. 2011

Collaborators

  • V J Cadarso
  • Bergoi Ibarlucea
  • Stephanus Büttgenbach
  • Cesar Fernandez-Sanchez
  • Jaume Veciana
  • Alberto Tarraga
  • Antonio Caballero
  • Inma Ratera
  • César Díez-Gil
  • Fabiola Zapata
  • Stephanie Demming
  • Pedro Molina
  • Stefanie Demming

Detail Information

Publications4

  1. doi request reprint PDMS based photonic lab-on-a-chip for the selective optical detection of heavy metal ions
    Bergoi Ibarlucea
    Instituto de Microelectronica de Barcelona, IMB CNM CSIC, Campus Universitat Autònoma de Barcelona, 08193, Bellaterra, Spain
    Analyst 138:839-44. 2013
    ....
  2. doi request reprint Fluorophore-doped xerogel antiresonant reflecting optical waveguides
    A Llobera
    Institut de Microelectrònica de Barcelona IMB CNM CSIC, Campus UAB 08193 Barcelona, Spain
    Opt Express 19:5026-39. 2011
    ..Finally, the total losses of the proposed waveguides are analyzed as a function of their width, obtaining losses close to 5 dB for waveguide widths higher than 50 µm...
  3. ncbi request reprint 3-D modulable PDMS-based microlens system
    V J Cadarso
    Institut de Microelectrònica de Barcelona IMB CNM CSIC, Campus UAB 08193 Barcelona, Spain
    Opt Express 16:4918-29. 2008
    ..Experimental results confirm the predicted numerical simulations, showing that, when the structure is under stretching conditions, the first focus is virtually invariable whereas the second focus becomes a Sturm zone...
  4. doi request reprint Selective functionalisation of PDMS-based photonic lab on a chip for biosensing
    Bergoi Ibarlucea
    Instituto de Microelectronica de Barcelona, IMB CNM CSIC, Campus UAB, 08193 Bellaterra, Spain
    Analyst 136:3496-502. 2011
    ..Considering all these studies, the PVA-modified approach appeared to be the most suitable one for the simple fabrication of a biosensor device integrated in a PDMS PhLoC...