Marlis T Sabo

Summary

Publications

  1. doi request reprint Reconstructing the interosseous membrane: a technique using synthetic graft and endobuttons
    Marlis T Sabo
    Upper Limb Unit, Wrightington Hospital, Wigan, Lancashire, UK
    Tech Hand Up Extrem Surg 16:187-93. 2012
  2. doi request reprint Osteochondral lesions of the capitellum do not affect elbow kinematics and stability with intact collateral ligaments: an in vitro biomechanical study
    Marlis T Sabo
    Bioengineering Laboratory, The Hand and Upper Limb Center, Lawson Research Institute, St Joseph s Health Care, University of Western Ontario, London, Ontario, Canada
    J Hand Surg Am 36:74-80. 2011
  3. doi request reprint The impact of capitellar arthroplasty on elbow contact mechanics: Implications for implant design
    M T Sabo
    Bioengineering Laboratory, The Hand and Upper Limb Centre, Lawson Research Institute, St Joseph s Health Care, The University of Western Ontario, London, ON, Canada
    Clin Biomech (Bristol, Avon) 26:458-63. 2011
  4. doi request reprint Capitellar excision and hemiarthroplasty affects elbow kinematics and stability
    Marlis T Sabo
    Hand and Upper Limb Centre, St Joseph s Health Care, London, ON, Canada
    J Shoulder Elbow Surg 21:1024-1031.e4. 2012
  5. doi request reprint A morphological analysis of the humeral capitellum with an interest in prosthesis design
    Marlis T Sabo
    Bioengineering Laboratory, The Hand and Upper Limb Center, Lawson Research Institute, St Joseph s Health Care, The University of Western Ontario, London, ON, Canada
    J Shoulder Elbow Surg 20:880-4. 2011
  6. doi request reprint Effect of coronal shear fractures of the distal humerus on elbow kinematics and stability
    Marlis T Sabo
    Bioengineering Laboratory, The Hand and Upper Limb Center, Lawson Research Institute, St Joseph s Health Care, The University of Western Ontario, London, ON, Canada
    J Shoulder Elbow Surg 19:670-80. 2010
  7. doi request reprint Landmarks for rotational alignment of the humeral component during elbow arthroplasty
    Marlis T Sabo
    Hand and Upper Limb Centre, St Joseph s Health Care, 268 Grosvenor Street, Suite D0 202, London, ON N6A 4L6, Canada
    J Bone Joint Surg Am 94:1794-800. 2012
  8. doi request reprint Comparing the fixation of a novel hollow screw versus a conventional solid screw in human sacra under cyclic loading
    Stewart D McLachlin
    Department of Mechanical and Materials Engineering, Jack McBain Biomechanical Testing Laboratory, Thompson Engineering Building, The University of Western Ontario, London, Ontario, Canada
    Spine (Phila Pa 1976) 33:1870-5. 2008

Collaborators

Detail Information

Publications8

  1. doi request reprint Reconstructing the interosseous membrane: a technique using synthetic graft and endobuttons
    Marlis T Sabo
    Upper Limb Unit, Wrightington Hospital, Wigan, Lancashire, UK
    Tech Hand Up Extrem Surg 16:187-93. 2012
    ..Further follow-up is required to determine the long-term durability of the construct, but early results are encouraging in a complex patient population...
  2. doi request reprint Osteochondral lesions of the capitellum do not affect elbow kinematics and stability with intact collateral ligaments: an in vitro biomechanical study
    Marlis T Sabo
    Bioengineering Laboratory, The Hand and Upper Limb Center, Lawson Research Institute, St Joseph s Health Care, University of Western Ontario, London, Ontario, Canada
    J Hand Surg Am 36:74-80. 2011
    ..The purpose of this in vitro study was to determine whether displaced OCD lesions of the capitellum lead to altered kinematics and stability of the elbow...
  3. doi request reprint The impact of capitellar arthroplasty on elbow contact mechanics: Implications for implant design
    M T Sabo
    Bioengineering Laboratory, The Hand and Upper Limb Centre, Lawson Research Institute, St Joseph s Health Care, The University of Western Ontario, London, ON, Canada
    Clin Biomech (Bristol, Avon) 26:458-63. 2011
    ..We hypothesized that capitellar replacement would decrease joint contact area relative to the native articulation; and an anatomical implant design would replicate more normal contact morphology than a spherical implant...
  4. doi request reprint Capitellar excision and hemiarthroplasty affects elbow kinematics and stability
    Marlis T Sabo
    Hand and Upper Limb Centre, St Joseph s Health Care, London, ON, Canada
    J Shoulder Elbow Surg 21:1024-1031.e4. 2012
    ..This study assessed the effect of capitellar excision with and without replacement on elbow kinematics and stability, and evaluated 2 different implant surface shapes...
  5. doi request reprint A morphological analysis of the humeral capitellum with an interest in prosthesis design
    Marlis T Sabo
    Bioengineering Laboratory, The Hand and Upper Limb Center, Lawson Research Institute, St Joseph s Health Care, The University of Western Ontario, London, ON, Canada
    J Shoulder Elbow Surg 20:880-4. 2011
    ..We hypothesized that the shape is more complex than originally believed, and cannot be accurately modeled as a spherical structure...
  6. doi request reprint Effect of coronal shear fractures of the distal humerus on elbow kinematics and stability
    Marlis T Sabo
    Bioengineering Laboratory, The Hand and Upper Limb Center, Lawson Research Institute, St Joseph s Health Care, The University of Western Ontario, London, ON, Canada
    J Shoulder Elbow Surg 19:670-80. 2010
    ..The amount of distal humerus that is safe to excise is unknown. This study examined the effect of excision of the capitellum and trochlea on elbow kinematics and stability with intact collateral ligaments...
  7. doi request reprint Landmarks for rotational alignment of the humeral component during elbow arthroplasty
    Marlis T Sabo
    Hand and Upper Limb Centre, St Joseph s Health Care, 268 Grosvenor Street, Suite D0 202, London, ON N6A 4L6, Canada
    J Bone Joint Surg Am 94:1794-800. 2012
    ..Our purpose was to assess whether the flat posterior humeral cortex proximal to the olecranon fossa is a reliable landmark with which to orient the humeral component during elbow arthroplasty...
  8. doi request reprint Comparing the fixation of a novel hollow screw versus a conventional solid screw in human sacra under cyclic loading
    Stewart D McLachlin
    Department of Mechanical and Materials Engineering, Jack McBain Biomechanical Testing Laboratory, Thompson Engineering Building, The University of Western Ontario, London, Ontario, Canada
    Spine (Phila Pa 1976) 33:1870-5. 2008
    ..The loosening rates of two monocortical pedicle screw designs (hollow and solid) were compared in a cadaveric sacrum model subjected to cyclic loading...