Vygandas Rutkunas

Summary

Publications

  1. ncbi request reprint Conventional and early loading of two-implant supported mandibular overdentures. A systematic review
    Vygandas Rutkunas
    Institute of Odontology, Faculty of Medicine, Vilnius University, Zalgirio str 115, 08217 Vilnius, Lithuania
    Stomatologija 10:51-61. 2008
  2. ncbi request reprint Maxillary complete denture outcome with two-implant supported mandibular overdentures. A systematic review
    Vygandas Rutkunas
    Institute of Odontology, Faculty of Medicine, Vilnius University, Zalgirio str 115, 08217 Vilnius, Lithuania
    Stomatologija 10:10-5. 2008
  3. doi request reprint A technique to splint and verify the accuracy of implant impression copings with light-polymerizing acrylic resin
    Vygandas Rutkunas
    Associate Professor, Faculty of Medicine, Division of Prosthodontics, Vilnius University, Institute of Odontology, Vilnius, Lithuania Electronic address
    J Prosthet Dent 111:254-6. 2014
  4. ncbi request reprint Effects of implant angulation, material selection, and impression technique on impression accuracy: a preliminary laboratory study
    Vygandas Rutkunas
    Vilnius University, Vilnius, Lithuania
    Int J Prosthodont 25:512-5. 2012
  5. ncbi request reprint Effects of different food colorants and polishing techniques on color stability of provisional prosthetic materials
    Vygandas Rutkunas
    Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Zalgirio str 115 217, Vilnius 08217, Lithuania
    Dent Mater J 29:167-76. 2010
  6. ncbi request reprint Effects of different repolishing techniques on colour change of provisional prosthetic materials
    Vygandas Rutkunas
    Institute of Odontology, Faculty of Medicine, Vilnius university Zalgirio str 115, 08217 Vilnius, Lithuania
    Stomatologija 11:102-12. 2009
  7. ncbi request reprint Influence of attachment wear on retention of mandibular overdenture
    V Rutkunas
    Center of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania
    J Oral Rehabil 34:41-51. 2007
  8. ncbi request reprint Evaluation of stable retentive properties of overdenture attachments
    Vygandas Rutkunas
    Center of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Zalgirio str 115, Room 231, 08217 Vilnius, Lithuania
    Stomatologija 7:115-20. 2005
  9. ncbi request reprint In vitro evaluation of cytotoxicity of permanent prosthetic materials
    Vaidotas Sabaliauskas
    Institute of Odontology, Faculty of Medicine, Vilnius University, Zalgirio str 115 219, Vilnius, Lithuania
    Stomatologija 13:75-80. 2011
  10. ncbi request reprint Veneer fracture in implant-supported metal-ceramic restorations. Part I: Overall success rate and impact of occlusal guidance
    Tomas Linkevicius
    Institute of Odontology, Faculty of Medicine, Vilnius University, Zalgirio str 115, LT 08217, Vilnius, Lithuania
    Stomatologija 10:133-9. 2008

Collaborators

Detail Information

Publications10

  1. ncbi request reprint Conventional and early loading of two-implant supported mandibular overdentures. A systematic review
    Vygandas Rutkunas
    Institute of Odontology, Faculty of Medicine, Vilnius University, Zalgirio str 115, 08217 Vilnius, Lithuania
    Stomatologija 10:51-61. 2008
    ..However, research results in this area are not consistent. The purpose of the study was to investigate the influence of conventional and early loading of two-implant supported mandibular overdentures on treatment outcomes...
  2. ncbi request reprint Maxillary complete denture outcome with two-implant supported mandibular overdentures. A systematic review
    Vygandas Rutkunas
    Institute of Odontology, Faculty of Medicine, Vilnius University, Zalgirio str 115, 08217 Vilnius, Lithuania
    Stomatologija 10:10-5. 2008
    ....
  3. doi request reprint A technique to splint and verify the accuracy of implant impression copings with light-polymerizing acrylic resin
    Vygandas Rutkunas
    Associate Professor, Faculty of Medicine, Division of Prosthodontics, Vilnius University, Institute of Odontology, Vilnius, Lithuania Electronic address
    J Prosthet Dent 111:254-6. 2014
    ..This report describes a straightforward method of splinting impression copings with light-polymerizing acrylic resin, with minimal amount of autopolymerizing acrylic resin. The method also can be used to verify splinting accuracy. ..
  4. ncbi request reprint Effects of implant angulation, material selection, and impression technique on impression accuracy: a preliminary laboratory study
    Vygandas Rutkunas
    Vilnius University, Vilnius, Lithuania
    Int J Prosthodont 25:512-5. 2012
    ..05), and increased angulation tended to decrease impression accuracy. The open-tray technique was more accurate with highly nonaxially oriented implants for the small sample size investigated...
  5. ncbi request reprint Effects of different food colorants and polishing techniques on color stability of provisional prosthetic materials
    Vygandas Rutkunas
    Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Zalgirio str 115 217, Vilnius 08217, Lithuania
    Dent Mater J 29:167-76. 2010
    ..Amongst the provisional materials tested, methacrylate-based resins exhibited the highest color stability irrespective of polishing technique and staining agent...
  6. ncbi request reprint Effects of different repolishing techniques on colour change of provisional prosthetic materials
    Vygandas Rutkunas
    Institute of Odontology, Faculty of Medicine, Vilnius university Zalgirio str 115, 08217 Vilnius, Lithuania
    Stomatologija 11:102-12. 2009
    ..CONCLUSION. Repolishing was found to be an effective way to improve aesthetic appearance for provisional prosthetic materials by partially removing staining observed on the surface of the restorations...
  7. ncbi request reprint Influence of attachment wear on retention of mandibular overdenture
    V Rutkunas
    Center of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania
    J Oral Rehabil 34:41-51. 2007
    ..Retentive properties of magnets decreased mostly with posterior rotational dislodgement. Retentive properties of stud overdenture attachments were less constant...
  8. ncbi request reprint Evaluation of stable retentive properties of overdenture attachments
    Vygandas Rutkunas
    Center of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Zalgirio str 115, Room 231, 08217 Vilnius, Lithuania
    Stomatologija 7:115-20. 2005
    ..Stud attachments are more susceptible to fatigue than magnets. Eight hundred cycles are required to achieve relatively stable retention of overdenture attachments...
  9. ncbi request reprint In vitro evaluation of cytotoxicity of permanent prosthetic materials
    Vaidotas Sabaliauskas
    Institute of Odontology, Faculty of Medicine, Vilnius University, Zalgirio str 115 219, Vilnius, Lithuania
    Stomatologija 13:75-80. 2011
    ..To assess qualitative and quantitative cytotoxicity effect on permanent prosthetic materials to human gingival fibroblasts...
  10. ncbi request reprint Veneer fracture in implant-supported metal-ceramic restorations. Part I: Overall success rate and impact of occlusal guidance
    Tomas Linkevicius
    Institute of Odontology, Faculty of Medicine, Vilnius University, Zalgirio str 115, LT 08217, Vilnius, Lithuania
    Stomatologija 10:133-9. 2008
    ..Material and..