Paolo Rossetti

Summary

Publications

  1. pmc Evaluation of a novel continuous glucose monitoring-based method for mealtime insulin dosing--the iBolus--in subjects with type 1 diabetes using continuous subcutaneous insulin infusion therapy: a randomized controlled trial
    Paolo Rossetti
    University Institute of Control Systems and Industrial Computing, Polytechnic University of Valencia, Valencia, Spain
    Diabetes Technol Ther 14:1043-52. 2012
  2. pmc Estimating plasma glucose from interstitial glucose: the issue of calibration algorithms in commercial continuous glucose monitoring devices
    Paolo Rossetti
    Instituto Universitario de Automatica e Informatica Industrial, Universidad Politecnica de Valencia, Camino de Vera, S N, 46022 Valencia, Spain
    Sensors (Basel) 10:10936-52. 2010
  3. pmc Combining basal-bolus insulin infusion for tight postprandial glucose control: an in silico evaluation in adults, children, and adolescents
    Ana Revert
    Instituto Universitario de Automatica e Informatica Industrial, Universidad Politecnica de Valencia, Camino de Vera s n, Valencia, Spain
    J Diabetes Sci Technol 4:1424-37. 2010
  4. pmc Commentary on "Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects"
    Paolo Rossetti
    Institut Universitari d Automàtica e Informàtica Industrial, Universitat Politècnica de València, Valencia, Spain
    J Diabetes Sci Technol 6:345-7. 2012
  5. doi request reprint Basal plus basal-bolus approach in type 2 diabetes
    F Javier Ampudia-Blasco
    Diabetes Reference Unit, Endocrinology and Nutrition Department, Clinic University Hospital of Valencia, Valencia, Spain
    Diabetes Technol Ther 13:S75-83. 2011
  6. doi request reprint A multiple local models approach to accuracy improvement in continuous glucose monitoring
    Fátima Barceló-Rico
    University Institute of Control and Industrial Informatics, Polytechnical University of Valencia, Valencia, Spain
    Diabetes Technol Ther 14:74-82. 2012

Collaborators

Detail Information

Publications6

  1. pmc Evaluation of a novel continuous glucose monitoring-based method for mealtime insulin dosing--the iBolus--in subjects with type 1 diabetes using continuous subcutaneous insulin infusion therapy: a randomized controlled trial
    Paolo Rossetti
    University Institute of Control Systems and Industrial Computing, Polytechnic University of Valencia, Valencia, Spain
    Diabetes Technol Ther 14:1043-52. 2012
    ..Based on continuous glucose monitoring (CGM), a method for prandial insulin administration (iBolus) is presented and evaluated for people with type 1 diabetes using CSII therapy...
  2. pmc Estimating plasma glucose from interstitial glucose: the issue of calibration algorithms in commercial continuous glucose monitoring devices
    Paolo Rossetti
    Instituto Universitario de Automatica e Informatica Industrial, Universidad Politecnica de Valencia, Camino de Vera, S N, 46022 Valencia, Spain
    Sensors (Basel) 10:10936-52. 2010
    ..The present review will analyze the issue of calibration algorithms for CGM, focusing exclusively on the commercially available glucose sensors...
  3. pmc Combining basal-bolus insulin infusion for tight postprandial glucose control: an in silico evaluation in adults, children, and adolescents
    Ana Revert
    Instituto Universitario de Automatica e Informatica Industrial, Universidad Politecnica de Valencia, Camino de Vera s n, Valencia, Spain
    J Diabetes Sci Technol 4:1424-37. 2010
    ..However, they are still based on empiric parameters such as the insulin-to-carbohydrate ratio and on the physicians' and patients' ability to fit bolus mode to meal composition...
  4. pmc Commentary on "Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects"
    Paolo Rossetti
    Institut Universitari d Automàtica e Informàtica Industrial, Universitat Politècnica de València, Valencia, Spain
    J Diabetes Sci Technol 6:345-7. 2012
    ..Educational programs aiming to increase patients' empowerment and caregivers' knowledge are needed in order to get full benefit of the technology...
  5. doi request reprint Basal plus basal-bolus approach in type 2 diabetes
    F Javier Ampudia-Blasco
    Diabetes Reference Unit, Endocrinology and Nutrition Department, Clinic University Hospital of Valencia, Valencia, Spain
    Diabetes Technol Ther 13:S75-83. 2011
    ..This article will review the currently evidence on the basal plus strategy and also its progression to basal-bolus therapy. In addition, practical recommendations to start and adjust basal plus therapy will be provided...
  6. doi request reprint A multiple local models approach to accuracy improvement in continuous glucose monitoring
    Fátima Barceló-Rico
    University Institute of Control and Industrial Informatics, Polytechnical University of Valencia, Valencia, Spain
    Diabetes Technol Ther 14:74-82. 2012
    ..Here we propose and validate an innovative calibration algorithm for the improvement of CGM performance...