Carlos Ricolfe-Viala

Summary

Publications

  1. doi request reprint Calibration of a trinocular system formed with wide angle lens cameras
    Carlos Ricolfe-Viala
    Instituto de Automática e Informática Industrial, Universitat Politècnica de València, Camino de Vera s n, Valencia, Spain
    Opt Express 20:27691-6. 2012
  2. doi request reprint Accurate calibration with highly distorted images
    Carlos Ricolfe-Viala
    Department of Systems Engineering and Automatic Control, Polytechnic University of Valencia, Camino de Vera s n, Valencia, D C 46022, Spain
    Appl Opt 51:89-101. 2012
  3. doi request reprint Lens distortion models evaluation
    Carlos Ricolfe-Viala
    Department of Systems Engineering and Automatic Control, Polytechnic University of Valencia, Camino de Vera s n, Valencia, DC 46022, Spain
    Appl Opt 49:5914-28. 2010
  4. doi request reprint Camera calibration under optimal conditions
    Carlos Ricolfe-Viala
    Instituto de Automática e Informática Industrial, Universitat Politècnica de València, Camino de Vera s n, Valencia 46022, Spain
    Opt Express 19:10769-75. 2011
  5. doi request reprint Calibration of a wide angle stereoscopic system
    Carlos Ricolfe-Viala
    Instituto de Automática e Informática Industrial, Universitat Politècnica de València, Camino de Vera, Valencia, Spain 46022
    Opt Lett 36:3064-6. 2011

Detail Information

Publications5

  1. doi request reprint Calibration of a trinocular system formed with wide angle lens cameras
    Carlos Ricolfe-Viala
    Instituto de Automática e Informática Industrial, Universitat Politècnica de València, Camino de Vera s n, Valencia, Spain
    Opt Express 20:27691-6. 2012
    ..First pixels locations in the images are corrected using a set of constraints which define the image formation in a trinocular system. When pixels location are corrected, lens distortion and trifocal tensor is computed...
  2. doi request reprint Accurate calibration with highly distorted images
    Carlos Ricolfe-Viala
    Department of Systems Engineering and Automatic Control, Polytechnic University of Valencia, Camino de Vera s n, Valencia, D C 46022, Spain
    Appl Opt 51:89-101. 2012
    ..The proposed method avoids the coupling between both models. Also, the condition of nonlinear minimization increases since points coordinates are computed alone...
  3. doi request reprint Lens distortion models evaluation
    Carlos Ricolfe-Viala
    Department of Systems Engineering and Automatic Control, Polytechnic University of Valencia, Camino de Vera s n, Valencia, DC 46022, Spain
    Appl Opt 49:5914-28. 2010
    ..Since performance is hard conditioned with the calibration technique, the metric lens distortion calibration method is used to calibrate all the evaluated models...
  4. doi request reprint Camera calibration under optimal conditions
    Carlos Ricolfe-Viala
    Instituto de Automática e Informática Industrial, Universitat Politècnica de València, Camino de Vera s n, Valencia 46022, Spain
    Opt Express 19:10769-75. 2011
    ..Optimal conditions define the number of points and the number of images to resolve the calibration accurately, as well as positions and orientations from where images should be taken...
  5. doi request reprint Calibration of a wide angle stereoscopic system
    Carlos Ricolfe-Viala
    Instituto de Automática e Informática Industrial, Universitat Politècnica de València, Camino de Vera, Valencia, Spain 46022
    Opt Lett 36:3064-6. 2011
    ..Geometrical constraints define the point localization in relation to its neighbors in the same image, and eipolar constraints represent the location of one point referred to its corresponding point in the other image...