Research Topics
| Antonio QueirosSummaryAffiliation: University of Minho Country: Portugal Publications
| Collaborators
|
Detail Information
Publications
Quality of life of myopic subjects with different methods of visual correction using the NEI RQL-42 questionnaireAntonio Queiros
Department of Physics, Clinical and Experimental Optometry Research Lab, Center of Physics, School of Sciences, University of Minho, Braga, Portugal
Eye Contact Lens 38:116-21. 2012....
Peripheral refraction in myopic eyes after LASIK surgeryAntonio Queiros
Clinical and Experimental Optometry Research Lab CEORLab, Center of Physics, Department of Physics, University of Minho, Braga, Portugal
Optom Vis Sci 89:977-83. 2012..This research took place at the Clinical Ophthalmologic-NovoVisión, Madrid, Spain...
Local steepening in peripheral corneal curvature after corneal refractive therapy and LASIKAntonio Queiros
School of Sciences, University of Minho, Braga, Portugal
Optom Vis Sci 87:432-9. 2010..The purpose of this study was to assess the changes in curvature along the horizontal meridian of the anterior cornea occurring after refractive surgery and corneal refractive therapy (CRT)...
Effect of pupil size on corneal aberrations before and after standard laser in situ keratomileusis, custom laser in situ keratomileusis, and corneal refractive therapyAntonio Queiros
Department of Physics, University of Minho, Braga, Portugal
Am J Ophthalmol 150:97-109.e1. 2010..To evaluate the effect of changing the pupil size on the corneal first-surface higher-order aberrations induced by different refractive treatments: standard laser in situ keratomileusis (LASIK), custom LASIK, and corneal refractive therapy...
Influence of fogging lenses and cycloplegia on open-field automatic refractionA Queiros
Department of Physics Optometry, School of Sciences, University of Minho, Braga, Portugal
Ophthalmic Physiol Opt 28:387-92. 2008..To compare refractive values measured with and without cycloplegia, or with fogging lenses, using an open-field auto-refractor...
Peripheral refraction in myopic patients after orthokeratologyAntonio Queiros
Clinical and Experimental Optometry Research Laboratory, Department of Physics Optometry, School of Sciences, University of Minho, Braga, Portugal
Optom Vis Sci 87:323-9. 2010..The purpose of this study was to characterize the central and peripheral refraction across the horizontal meridian of the visual field before and after myopic corneal refractive therapy (CRT) with contact lenses...
Technical note: Accuracy and repeatability of a new portable ultrasound pachymeterA Queiros
Department of Physics Optometry, School of Sciences, Campus de Gualtar, University of Minho, 4710 057 Braga, Portugal
Ophthalmic Physiol Opt 27:190-3. 2007..To assess the accuracy and repeatability of central corneal thickness (CCT) measurements taken with a new portable ultrasound (US) pachymeter...
Anterior and posterior corneal elevation after orthokeratology and standard and customized LASIK surgeryAntonio Queiros
Clinical and Experimental Optometry Research Laboratory CEORLab, Madrid, Spain
Eye Contact Lens 37:354-8. 2011....
Non-contact tonometry synchronized with cardiac rhythm and its relationship with blood pressureA Queiros
Department of Physics Optometry, School of Sciences, University of Minho, Braga, Portugal
Ophthalmic Physiol Opt 26:384-91. 2006....
Pilot study on the influence of corneal biomechanical properties over the short term in response to corneal refractive therapy for myopiaJose Manuel Gonzalez-Meijome
Department of Physics Optometry, School of Sciences, University of Minho, Braga, Portugal
Cornea 27:421-6. 2008..To study the short-term corneal response to corneal refractive therapy for myopia and correlate it with corneal biomechanical properties as measured with the ocular response analyzer...
Correlations between corneal biomechanical properties measured with the ocular response analyzer and ICare rebound tonometryJorge Manuel Martins Jorge
Department of Physics Optometry, School of Sciences, University of Minho, Braga, Portugal
J Glaucoma 17:442-8. 2008..To investigate the biomechanical properties of the normal cornea, and correlate them with central and peripheral corneal thickness and age...
Short-term corneal response to corneal refractive therapy for different refractive targetsCésar Villa-Collar
Clínica Oftalmologica Novovision SL, Madrid, Spain
Cornea 28:311-6. 2009....
Intraoffice variability of corneal biomechanical parameters and intraocular pressure (IOP)Jose M Gonzalez-Meijome
Department of Physics, University of Minho, Braga, Portugal
Optom Vis Sci 85:457-62. 2008..To evaluate the intraoffice hour variability of intraocular pressure (IOP) and in vivo biomechanical properties of the cornea, as measured with the Ocular Response Analyzer (ORA)...
High-resolution spectral domain optical coherence tomography technology for the visualization of contact lens to cornea relationshipsJose M Gonzalez-Meijome
Clinical and Experimental Optometry Research Lab, University of Minho, Braga, Portugal
Cornea 29:1359-67. 2010..To study the utility of high-resolution spectral domain optical coherence tomography (HR SOCT) in imaging the contact lens (CL) to cornea relationships with advanced CL designs for ecstatic corneas and corneal refractive therapy...
A comparison of the NCT Reichert R7 with Goldmann applanation tonometry and the Reichert ocular response analyzerJorge Jorge
Clinical and Experimental Optometry Research Lab, Center of Physics, School of Science, University of Minho, Braga, Portugal
Ophthalmic Physiol Opt 31:174-9. 2011..Other ocular dimensions were assessed to evaluate their potential influence on the IOP values obtained...
IOP variations in the sitting and supine positionsJorge Jorge
Clinical and Experimental Optometry Research Lab, Department of Physics Optometry, School of Sciences, University of Minho, Braga, Portugal
J Glaucoma 19:609-12. 2010..The aim of this study was to assess the influence of the position (upright vs. supine) in the intraocular pressure (IOP) measured with a non-contact portable tonometer...
Two single descriptors of endothelial polymegethism and pleomorphismJose Manuel Gonzalez-Meijome
Clinical and Experimental Optometry Research Lab, Department of Physics Optometry, School of Sciences, University of Minho, Campus de Gualtar, 4710 057, Braga, Portugal
Graefes Arch Clin Exp Ophthalmol 248:1159-66. 2010..To compute two new quantitative parameters that directly reflect the level of polymegethism and pleomorphism using data provided by a non-contact specular microscope...
Comparison of the IOPen and iCare rebound tonometers with the Goldmann tonometer in a normal populationJ Jorge
Department of Physics Optometry, School of Sciences, University of Minho, Campus de Gualtar, Braga
Ophthalmic Physiol Opt 30:108-12. 2010..Based on the present population study, these results suggest that IOPen measurements should be interpreted with caution...
Clinical evaluation of the IOPen® in a glaucomatous populationJ Jorge
Center of Physics, School of Science, University of Minho, Campus de Gualtar, Braga, Portugal
Ophthalmic Physiol Opt 30:860-4. 2010..6% of the measurements the IOP readings differed by more than 3 mmHg between the two tonometers. These results suggest that IOPen® should be used with great caution in the determination of IOP...
Age differences in central and peripheral intraocular pressure using a rebound tonometerJ M Gonzalez-Meijome
Department of Physics Optometry, School of Science, University of Minho, Braga, Portugal
Br J Ophthalmol 90:1495-500. 2006..To evaluate the influence of age on the measurements and relationships among central and peripheral intraocular pressure (IOP) readings taken with a rebound tonometer...
Comparison of the ICare rebound tonometer with the Goldmann tonometer in a normal populationP Fernandes
Department of Physics Optometry, School of Sciences, University of Minho, Braga, Portugal
Ophthalmic Physiol Opt 25:436-40. 2005..00 mmHg in more than 80% of the population...
Clinical performance and "ex vivo" dehydration of silicone hydrogel contact lenses with two new multipurpose solutionsJose Manuel Gonzalez-Meijome
Clinical and Experimental Optometry Research Lab, Center of Physics, University of Minho, Braga, Portugal
Cont Lens Anterior Eye 36:86-92. 2013....
External factors affecting data acquisition during corneal topography examinationJose Manuel Gonzalez Meijome
Department of Physics Optometry, School of Sciences, University of Minho, Braga, Portugal
Eye Contact Lens 33:91-7. 2007..To analyze the factors affecting data acquisition during corneal topography examination with the Medmont E-300 videokeratoscope and to provide strategies to minimize their effects...
Technical note: a comparison of central and peripheral intraocular pressure using rebound tonometryA Queiros
Department of Physics Optometry, School of Sciences, University of Minho, Braga, Portugal
Ophthalmic Physiol Opt 27:506-11. 2007..To compare central and peripheral intraocular pressure (IOP) readings obtained with rebound tonometry...
Peripheral refraction and retinal contour in stable and progressive myopiaMiguel Faria-Ribeiro
Clinical and Experimental Optometry Research Lab, Center of Physics, University of Minho, Braga, Portugal
Optom Vis Sci 90:9-15. 2013..To compare the patterns of relative peripheral astigmatic refraction (tangential and sagittal power errors) and eccentric eye length between progressing and stable young-adult myopes...
Retinoscopy/autorefraction: which is the best starting point for a noncycloplegic refraction?Jorge Jorge
Department of Physics Optometry, School of Sciences, University of Minho, Braga, Portugal
Optom Vis Sci 82:64-8. 2005..The aim of this study was to estimate the agreement between an autorefractor (Nidek ARK 700A, Gamagori, Japan) and retinoscopy with subjective refraction...
