Marian J Surma

Summary

Affiliation: University of Lodz
Country: Poland

Publications

  1. ncbi Uncertainty analysis of (99m)Tc-HEPIDA liver clearance determination
    Marian J Surma
    Nuclear Medicine Department of the Medical University of Łódź, Poland
    Nucl Med Rev Cent East Eur 8:116-24. 2005
  2. ncbi (99m)Tc-HEPIDA hepatic clearance as a diagnostic tool: usefulness of a single sample plasma and hepatic clearance of (99m)Tc-HEPIDA for assessment of hepatic parenchyma performance
    Marian J Surma
    Nuclear Medicine Department, Central University Hospital, ul Czechoslowacka 8 10, 92 216 Łódź, Poland
    Nucl Med Rev Cent East Eur 9:125-31. 2006
  3. ncbi Comparison of (99m)Tc-HEPIDA and (99m)Tc-MBrIDA from the standpoint of hepatic clearance determination-- preliminary communication
    Marian J Surma
    Department of Nuclear Medicine, Medical University of Lodz, Poland
    Nucl Med Rev Cent East Eur 12:72-7. 2009
  4. ncbi Assessment of accuracy and precision of (99m)Tc-HEPIDA clearances determined by means of a simplified method
    Marian J Surma
    Nuclear Medicine Department, Medical University of Łódź, Poland
    Nucl Med Rev Cent East Eur 12:14-22. 2009
  5. ncbi Conventional and parametric kidney scintigrams - reproducibility of semiquantitative image evaluation
    Izabela Frieske
    Department of Nuclear Medicine, Medical University of Lodz, Poland
    Nucl Med Rev Cent East Eur 11:22-5. 2008
  6. ncbi Specific 99mTC-HEPIDA hepatic clearance--essential value ranges from a clinical stand-point
    Izabela Frieske
    Department of Nuclear Medicine, Central Clinical Hospital, Medical University of Lodz, Poland
    Nucl Med Rev Cent East Eur 9:56-9. 2006
  7. ncbi Parametric clearance kidney scintigrams; diagnostic potential in diabetes
    Izabela Frieske
    Department of Nuclear Medicine, Medical University of Lodz, Lodz, Poland
    Nucl Med Rev Cent East Eur 10:16-20. 2007
  8. ncbi 99mTc-HEPIDA hepatic clearance as a diagnostic tool: usefulness of plasma and hepatic clearance for assessment of hepatic parenchyma performance
    Izabela Frieske
    Nuclear Medicine Department of the Medical University, d, Poland
    Nucl Med Rev Cent East Eur 6:23-8. 2003

Collaborators

  • Jacek Kusmierek
  • Agnieszka Szadkowska
  • Izabela Frieske
  • Małgorzata Bienkiewicz
  • Ewa Pietrzak-Stelmasiak
  • Mariusz Gadzicki
  • Agnieszka Rogozińska-Zawiślak
  • Jerzy Bodalski
  • Jan Kuydowicz
  • Julian Liniecki

Detail Information

Publications8

  1. ncbi Uncertainty analysis of (99m)Tc-HEPIDA liver clearance determination
    Marian J Surma
    Nuclear Medicine Department of the Medical University of Łódź, Poland
    Nucl Med Rev Cent East Eur 8:116-24. 2005
    ....
  2. ncbi (99m)Tc-HEPIDA hepatic clearance as a diagnostic tool: usefulness of a single sample plasma and hepatic clearance of (99m)Tc-HEPIDA for assessment of hepatic parenchyma performance
    Marian J Surma
    Nuclear Medicine Department, Central University Hospital, ul Czechoslowacka 8 10, 92 216 Łódź, Poland
    Nucl Med Rev Cent East Eur 9:125-31. 2006
    ....
  3. ncbi Comparison of (99m)Tc-HEPIDA and (99m)Tc-MBrIDA from the standpoint of hepatic clearance determination-- preliminary communication
    Marian J Surma
    Department of Nuclear Medicine, Medical University of Lodz, Poland
    Nucl Med Rev Cent East Eur 12:72-7. 2009
    ..From the performed investigations it is possible to conclude that (99m)Tc-MBrIDA clearances may be used for the evaluation of liver parenchyma performance, even if the results may not be as certain as those obtained using (99m)Tc-HEPIDA...
  4. ncbi Assessment of accuracy and precision of (99m)Tc-HEPIDA clearances determined by means of a simplified method
    Marian J Surma
    Nuclear Medicine Department, Medical University of Łódź, Poland
    Nucl Med Rev Cent East Eur 12:14-22. 2009
    ..The aim of the present study was the assessment of the accuracy and precision of our own simplified method for the determination of (99m)Tc-HEPIDA liver clearance...
  5. ncbi Conventional and parametric kidney scintigrams - reproducibility of semiquantitative image evaluation
    Izabela Frieske
    Department of Nuclear Medicine, Medical University of Lodz, Poland
    Nucl Med Rev Cent East Eur 11:22-5. 2008
    ..The aim of this study was the evaluation of the reproducibility of semiquantitative parametric kidney image evaluation...
  6. ncbi Specific 99mTC-HEPIDA hepatic clearance--essential value ranges from a clinical stand-point
    Izabela Frieske
    Department of Nuclear Medicine, Central Clinical Hospital, Medical University of Lodz, Poland
    Nucl Med Rev Cent East Eur 9:56-9. 2006
    ..72m(-2)--indicates a substantial impairment of liver function (damage). Values of Cl(Hp) <or= 90 ml min(-1) 1.72 m(-2) are highly specific for serious liver damage, of intensity typical for cirrhosis of the organ...
  7. ncbi Parametric clearance kidney scintigrams; diagnostic potential in diabetes
    Izabela Frieske
    Department of Nuclear Medicine, Medical University of Lodz, Lodz, Poland
    Nucl Med Rev Cent East Eur 10:16-20. 2007
    ....
  8. ncbi 99mTc-HEPIDA hepatic clearance as a diagnostic tool: usefulness of plasma and hepatic clearance for assessment of hepatic parenchyma performance
    Izabela Frieske
    Nuclear Medicine Department of the Medical University, d, Poland
    Nucl Med Rev Cent East Eur 6:23-8. 2003
    ..In conclusion this quantity seems highly promising as a clinically useful test for assessment of liver performance, both in screening for liver damage and for monitoring of organ conditions during therapy and follow-up of patients...